46 Figure 4-25 4.1.12 Multicast The multicast interface is shown as in Figure 4-26. Multicast is a transmission mode of data packet. When there is multiple-host to receive the same data packet, multiple-cast is the best option to reduce the broad width and the CPU load. The source host can just send out one data to transit. This function also depends on the relationship of the group member and group of the outer. Note: Open preview, streaming media protocol, select multicast, and monitor via multicast format. Here you can set multicast address and port. You also need to go to Live interface to set the protocol as Multicast.
47 Figure 4-26 Please refer to the following sheet for detailed information. 4.1.13 802.1x 802.1x (port based network access control protocol) supports manual selection of authentication method to control if device connected to LAN can join the LAN. It well supports authentication, charging, safety and management requirement of network. Parameter Function Enable Select to enable multicast function. Main stream and sub stream cannot be used at the same time. Multicast address Main/sub stream multicast default address is 224.1.2.4 and its range is 224.0.0.0~239.255.255.255. Port Multicast port. Main stream is 40000, sub stream is 40002 and the range is 1025~65534.
48 Figure 4-27 Please refer to the following sheet for detailed information. Parameter Function Authentication PEAP (protected EAP protocol). Username It needs the username to login, which is authenticated by the server. Password Please input password here. 4.1.14 QoS The QoS interface is shown as below. See Figure 4-28. Qos (Quality of Service) is network security mechanism. It is a technology to fix the network delay and jam problem and etc. For the network service, the quality of service includes the transmission bandwidth, delay, the packet loss and etc. We can guarantee the transmission bandwidth, lower the delay, reduce the loss of the data packet and anti-dither to enhance the quality. We can set the DSCP (Differentiated Services Code Point) of the IP to distinguish the data packet so that the router or the hub can provide different services for various data packets. It can select the different queues according to the priority (64 different priority levels) of the packets and select the bandwidth of the each queue. Level 0 is the lowest, and level 63 is the highest. It can also discard at the different ratio when the broad bandwidth is jam.
49 Figure 4-28 Please refer to the following sheet for detailed information. Parameter Function Real-time monitor The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets. Command The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets. Enable Wireless QoS Check it to enable QoS. 4.2 Event 4.2.1 Video detect 4.2.1.1 Motion Detect The motion detect interface is shown as in below.
51 Figure 4- 31 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable motion detection function. Enable video mask detection You need to check the box to enable video mask detection alarm. Enable defocus detection You need to check the box to enable defocus detection alarm. Working Period Here you can set arm/disarm period. Click on set button to open period setup menu. There are six periods every day for setup and you must check box in front of each period to enable it. Note: Period setup can be done by dragging mouse while not release left mouse. Anti-dither System only memorizes one event during the anti-dither period. The value ranges from 0s to 100s.
52 Parameter Function Area Here you can set motion detection region and its sensitivity and area. (The higher the sensitivity is, the easier to trigger motion detect; the smaller the area, the easier to trigger motion detect.) The default covers all regions. You must click on save before enabling your setup. Record Check it and so when alarm occurs, system will auto record. You shall set record period in Storage>Schedule and select auto record in record control interface. Record Delay System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s. Relay out Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs. Alarm Delay System can delay the alarm output for specified time after alarm ended. The value ranges from 10s to 300s. Send Email If you enabled this function, System can send out email to alert you when alarm occurs and ends. User can set email address in Network>SMTP. Audio linkage Check it and the system will play alarm audio file when alarm occurs. Users can set the recorded or uploaded audio file in “camera setting > audio > alarm audio”. Flash linkage Check it and the flash will be on when alarm occurs, and the flash will be off until the end of alarm after corresponding delay. PTZ Here you can set PTZ movement when alarm occurs. Such as go to preset x when there is an alarm. The event type includes: preset, tour and pattern. Snapshot You need to check the box here so that system can backup motion detection snapshot file. You shall set snapshot period in Storage>Schedule. See Figure 4-32.
53 Figure 4-32 Different colors represent different areas. Each area can set different detection zones. Detection zone can be irregular and discontinuous. Please refer to the following sheet for detailed information. Parameter Function Name Default area name includes Region1, Region2, Region3, Region4 and custom. Sensitivity It is sensitivity of brightness as motion detection is more possible to be trigger with higher sensitivity. You can set up different sensitivities. The range is 0~100. The recommenced value is 30~70. Area threshold It is to check the relationship between object and its area. The lower the area threshold, the easier to trigger motion detection. You can set up different threshold for each area. The range is 0~100. The recommenced value is 0~10. Waveform Red means motion detect is triggered. Green means motion detect is not triggered. Delete all Clear all the detection areas with color.
54 Delete Delete selected area. 4.2.2 Abnormity Abnormity includes No SD Card, Capacity Warning, SD Card Error, Disconnection, IP Conflict and Unauthorized Access. Note: Only device with SD card function has these three statuses: No SD card, capacity warning, and SD card error. Device without SD card function does not have the above three statuses. See Figure 5-61 to Figure 4- 33. Figure 4-33 Figure 4-34
55 Figure 4-35 Please refer to the following sheet for detailed information. Parameter Function Enable Check to alarm when SD card is abnormal. Relay-out Check to enable relay-out alarm. Relay out delay The alarm output can delay for the specified time after alarm stops. The value ranges from 10s to 300s. Note: No SD card, capacity warning, SD card error, relay-out delay all start from alarm occurs. Send email After you enabled this function, the system can send out email to alarm the specified user. This function is invalid when network is offline or IP conflict occurs. SD Card Capacity Limit User can set SD card capacity that is left free. When SD card space left is smaller than this limit, alarm occurs. When device is offline or IP conflicts, the abnormal alarm is similar with case of SD card error.