Page 51

                                              
 46 
 
Figure 4-25 
4.1.12 Multicast 
The multicast interface is shown as in Figure 4-26. 
Multicast is a transmission mode of data packet. When there is multiple-host to receive the same data 
packet, multiple-cast is the best option to reduce the broad width and the CPU load.  The source host 
can just send out one data to transit. This function also depends on the relationship of the group 
member and group of the outer.  
Note: 
 Open preview, streaming...

Page 52

                                              
 47 
 
 
Figure 4-26 
 
Please refer to the following sheet for detailed information.  
 
4.1.13 802.1x 
802.1x (port based network access control protocol) supports manual selection of authentication 
method to control if device connected to LAN can join the LAN. It well supports authentication, charging, 
safety and management requirement of network. 
             
 
 
 
 
 
 
Parameter  Function  
Enable Select to enable multicast function. Main stream...

Page 53

                                              
 48 
 
 
Figure 4-27 
 
Please refer to the following sheet for detailed information.  
Parameter  Function  
Authentication PEAP (protected EAP protocol).   
Username It needs the username to login, which is authenticated by the 
server. 
Password Please input password here.  
 
4.1.14 QoS 
The QoS interface is shown as below. See Figure 4-28. 
Qos (Quality of Service) is network security mechanism. It is a technology to fix the network delay and 
jam...

Page 54

                                              
 49 
 
Figure 4-28 
Please refer to the following sheet for detailed information.  
Parameter  Function  
Real-time 
monitor  
The value ranges from 0 to 63. The router or the switcher can 
provide different service for various data packets.  
Command  The value ranges from 0 to 63. The router or the switcher can 
provide different service for various data packets. 
Enable 
Wireless QoS 
Check it to enable QoS. 
 
4.2 Event  
4.2.1 Video detect 
4.2.1.1...

Page 55

                                              
 50 
 
Figure 4-29 
 
 
Figure 4- 30 
 
  

Page 56

                                              
 51 
 
Figure 4- 31 
Please refer to the following sheet for detailed information.  
Parameter Function  
Enable  You need to check the box to enable motion detection function.  
Enable video 
mask detection  
You need to check the box to enable video mask detection alarm. 
Enable defocus 
detection  
You need to check the box to enable defocus detection alarm. 
Working Period  Here you can set arm/disarm period. Click on set button to open period 
setup...

Page 57

                                              
 52 
Parameter Function  
Area  Here you can set motion detection region and its sensitivity and area. (The 
higher the sensitivity is, the easier to trigger motion detect; the smaller the 
area, the easier to trigger motion detect.) The default covers all regions. 
You must click on save before enabling your setup.  
Record Check it and so when alarm occurs, system will auto record. You shall set 
record period in Storage>Schedule and select auto record in...

Page 58

                                              
 53 
 
Figure 4-32 
Different colors represent different areas. Each area can set different detection zones. Detection zone 
can be irregular and discontinuous.  
Please refer to the following sheet for detailed information.  
 
Parameter Function  
Name Default area name includes Region1, Region2, Region3, 
Region4 and custom.  
Sensitivity  It is sensitivity of brightness as motion detection is more possible 
to be trigger with higher sensitivity. You can...

Page 59

                                              
 54 
Delete Delete selected area.  
 
4.2.2 Abnormity 
Abnormity includes No SD Card, Capacity Warning, SD Card Error, Disconnection, IP Conflict and 
Unauthorized Access.  
Note: 
Only device with SD card function has these three statuses: No SD card, capacity warning, and SD card 
error.  
Device without SD card function does not have the above three statuses. See Figure 5-61 to Figure 4-
33.  
 
Figure 4-33 
 
 
Figure 4-34  

Page 60

                                              
 55 
 
 
Figure 4-35 
Please refer to the following sheet for detailed information.  
Parameter  Function  
Enable Check to alarm when SD card is abnormal.  
Relay-out Check to enable relay-out alarm.  
Relay out 
delay  
The alarm output can delay for the specified time after alarm stops. The 
value ranges from 10s to 300s. 
Note: 
No SD card, capacity warning, SD card error, relay-out delay all start 
from alarm occurs.  
Send 
email  
After you enabled...