    Have a look at the manual Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Chapter 5 Maintenance — Self-diagnosis display
    ENGLISH - 191
    Error/warning displayDetails Measure
    UA1 FPGA temperature warning
     fThe operating environment temperature is too 
    high. Use the projector in an appropriate operating 
    environment temperature
    *1.
    UA4
    Power supply temperature error
    UA5 FPGA temperature error
    H01 Battery replacement for the internal clock
     fBattery replacement is required. Consult your 
    dealer
    
    .
    H 11 Intake temperature sensor not present
     fIf the display does not clear after switching the 
    main power of
    
    f and on, consult your dealer.
    H12
    Optical module temperature sensor not present
    H13 Exhaust air temperature sensor not present
    H18 Clog sensor not present
    F00 Liquid cooling pump R warning
     fIf the display does not clear after switching the 
    main power of
    
    f and on, consult your dealer.
    F01
    Liquid cooling pump G warning
    F02 Liquid cooling pump B warning
    F 11 Shutter error
    F12 Dynamic iris error
    F13 Air filter unit error
    F15 Luminance sensor error
    F16 Angle sensor error
    F41 Lamp 1 memory error
     fThe lamp unit is broken. Consult your dealer
    
    .
    F42
    Lamp 2 memory error
    F43 Lamp 3 memory error
    F44 Lamp 4 memory error
    F50 Exhaust fan 1 warning
     fIf the display does not clear after switching the 
    main power of
    
    f and on, consult your dealer.
    F51
    Exhaust fan 2 warning
    F52 Exhaust fan 3 warning
    F53 Exhaust fan 4 warning
    F54 Intake fan 1 warning
    F55 Intake fan 2 warning
    F56 Lamp 1 fan warning
    F57 Lamp 2 fan warning
    F58 Lamp 3 fan warning
    F59 Lamp 4 fan warning
    F61 Lamp 1 power supply communication error
    F62 Lamp 2 power supply communication error
    F63 Lamp 3 power supply communication error
    F64 Lamp 4 power supply communication error
    F70 Lamp 1 power supply fan warning
    F71 Lamp 2 power supply fan warning
    F72 Power supply fan warning
    F73 Signal fan warning
    F74 Lamp 1/2 relay fan warning
    F75 Lamp 3/4 relay fan warning
    F76 Color prism fan 1 warning
    F77 Color prism fan 2 warning
    F78 Color prism fan 3 warning
    F79 Color prism fan 4 warning   
    						
    							Chapter 5 Maintenance — Self-diagnosis display
    192 - ENGLISH
    Error/warning displayDetails Measure
    F91 FPGA1/2 configuration error
     fIf the display does not clear after switching the 
    main power of
    
    f and on, consult your dealer.
    F92
    FPGA3 configuration error
    F96 Lens mounter error
    FE0 Color prism fan 4 error
    FE1 Exhaust fan 1 error
    FE2 Exhaust fan 2 error
    FE3 Exhaust fan 3 error
    FE4 Exhaust fan 4 error
    FE5 Intake fan 1 error
    FE6 Intake fan 2 error
    FE7 Lamp 1 fan error
    FE8 Lamp 2 fan error
    FE9 Lamp 3 fan error
    FF0 Lamp 4 fan error
    FF1 Lamp 1/2 power supply fan error
    FF2 Lamp 3/4 power supply fan error
    FF3 Power supply fan error
    FF4 Signal fan error
    FF5 Lamp 1/2 relay fan error
    FF6 Lamp 3/4 relay fan error
    FF7 Color prism fan 1 error
    FF8 Color prism fan 2 error
    FF9 Color prism fan 3 error
    FJ0 Liquid cooling pump R error
    FJ1 Liquid cooling pump G error
    FJ2 Liquid cooling pump B error
    *1 Refer to “Operating environment temperature” ( x   page   216) for the operating environment temperature of the projector.
    *2  Only for PT- DZ16K2
    *3
     
    800 hours when using the optional Replacement lamp unit (for portrait mode) (Model No.: ET-
     LAD520P (1   pc), ET
    -
     LAD520PF (4   pcs)).
    Note
     fThe self-diagnosis display and the details of the malfunction may vary . fFor errors and warnings that are not described in the table, consult your dealer .   
    						
    							ENGLISH - 193
    Chapter 6 Appendix
    This chapter describes specifications and after-sales service for the projector. 
    						
    							Chapter 6 Appendix — Technical information
    194 - ENGLISH
    Technical information
    PJLink protocol
    The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to perform 
    projector setting and projector status query operations from a computer.
    Control commands
    The following table lists the PJLink protocol commands that can be used to control the projector .
     fx characters in tables are non-specific characters.
    Command Control details Parameter/response 
    string Remark
    POWR Power supply control 0
    Standby
    1 Power on
    POWR? Power supply status 
    query 0
    Standby
    1 Power on
    2 Preparing for switching off the projector
    3 Warm-up
    INPT Input selection 11
    RGB1
    12 RGB2
    INPT? Input selection query 31
    DVI
    - D
    32 HDMI
    33 DIGITAL LINK
    34 SDI1 (Only for PT
    -
    
    DZ21K2, PT
    -
     DS20K2, PT
    -
     DZ16K2)
    35 SDI2 (Only for PT
    -
    
    DZ21K2, PT
    -
     DS20K2)
    AVMT Shutter control 30 Shutter function disabled (shutter: open)
    AVMT? Shutter status query 31Shutter function enabled (shutter: closed)
    ERST? Error status query xxxxxx 1st byte
    Indicates fan errors, and returns 
    0 - 2.
     f
    0 = No error is 
    detected
     f1 = W
    
    arning
     f2 = Error
    2nd byte
    Indicates lamp errors, and returns 
    0 - 2.
    3rd byte Indicates temperature errors, and 
    returns 0 - 2.
    4th byte Indicates cover open errors, and 
    returns 0 - 2.
    5th byte Indicates filter errors, and returns 
    0 - 2.
    6th byte Indicates other errors, and returns 
    0 - 2.
    LAMP? Lamp status query xxxxxxxxxxxxxxxxxxxxxxxx 1st number (1 - 5 digits): Lamp 1 runtime
    2nd number: 0 = Lamp 1 of
    
    f, 1 = Lamp 1 on
    3rd number (1 - 5 digits): Lamp 2 runtime
    4th number: 0 = Lamp 2 off, 1 = Lamp 2 on
    5th number (1 - 5 digits): Lamp 3 runtime
    6th number: 0 = Lamp 3 off, 1 = Lamp 3 on
    7th number (1 - 5 digits): Lamp 4 runtime
    8th number: 0 = Lamp 4 off, 1 = Lamp 4 on
    INST? Input selection list query 11 12 31 32 33 34 35 Only for PT
    -
    
    DZ21K2, PT
    -
     DS20K2
    11 12 31 32 33 Only for PT
    -
    
    DW17K2
    11 12 31 32 33 34 Only for PT
    -
    
    DZ16K2
    NAME? Projector name query xxxxx Returns the name set in [PROJECTOR NAME] of [NETWORK 
    SETUP].
    INF1? Manufacturer name 
    query Panasonic
    Returns manufacturer name.
    INF2? Model name query DZ21K2
    Returns model name.
    DS20K2
    DW17K2
    DZ16K2
    INF0? Other information 
    queries xxxxx
    Returns information such as version number.
    CLSS? Class information query 1Returns class for PJLink.  
    						
    							Chapter 6 Appendix — Technical information
    ENGLISH - 195
    PJLink security authentication
    The password used for PJLink is the same as that of the password set for web control.
    When using the projector without security authentication, do not set a p\
    assword for web control.
     fFor specifications related to PJLink, visit the website of Japan Business Machine and Information System 
    Industries 
    
    Association.
    URL http://pjlink.jbmia.or.jp/english/
    Using Art-Net function
    Since the network function of the projector supports the Art-Net function, you can control the projector settings 
    with the DMX controller and application software using the Art-Net protocol.
    Channel definition
    The following table lists the channel definitions used for controlling the projector with the  Art-Net function.
    Channel settings can be switched using the [NETWORK] menu  → [Art-Net CHANNEL SETTING] (x
      page   157).
    The control details assigned to each channel are listed in the following\
     table.
     f Channel assignment for [USER] is in factory default setting. 
    
    Assignment can be changed.
    Channel Control details
    [2] [USER] [1]
    CHANNEL1 LIGHT OUTPUT LIGHT OUTPUT SHUTTER
    CHANNEL2 INPUT SELECT INPUT SELECT INPUT SELECT
    CHANNEL3 LENS POSITION LENS POSITIONLENS FUNCTION SELECT
    CHANNEL4 LENS H SHIFT LENS H SHIFTLENS CONTROL
    CHANNEL5 LENS V SHIFT LENS V SHIFT POWER
    CHANNEL6 LENS FOCUS LENS FOCUSLIGHT OUTPUT
    CHANNEL7 LENS ZOOM LENS ZOOMENABLE/DISABLE
    CHANNEL8 POWERPOWER FADE-IN
    CHANNEL9 GEOMETRY GEOMETRY FADE-OUT
    CHANNEL10 CUSTOM MASKING
    *1CUSTOM MASKING*1CUSTOM MASKING*1
    CHANNEL11 ENABLE/DISABLE ENABLE/DISABLE GEOMETRY
    CHANNEL12 NONENONE NONE
    *1 For PT-DZ21K2 and PT- DS20K2. “NONE” for PT- DW17K2 and PT- DZ16K2.
     rControl details
    Control details PerformanceParameter Default value Remark
    LIGHT OUTPUT 100
      % 0
    0Can be set in 256 steps between 
    100
      % and 0   %.
    …
    …
    0
      % 255
    INPUT SELECT (when [1] is 
    selected) No operation
    0
    - 7
    0 ―
    RGB1
    8
    - 15
    RGB2 16
    - 23
    No operation 24
    - 31
    DVI
    - D 32
    - 39
    HDMI 40
    - 47
    SDI1 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2, PT
    -
     DZ16K2)48
    - 55
    SDI2 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2) 56
    - 63
    No operation 64
    - 127
    P IN P execution, USER1 128
    - 135
    P IN P execution, USER2 136
    - 143
    P IN P execution, USER3 144
    - 151
    No operation 152
    - 255  
    						
    							Chapter 6 Appendix — Technical information
    196 - ENGLISH
    Control detailsPerformanceParameter Default value Remark
    INPUT SELECT (when [2] or 
    [USER] is selected) No operation
    0
    - 7
    0 ―
    RGB1
    8
    - 15
    RGB2 16
    - 23
    DVI
    - D 24
    - 31
    HDMI 32
    - 39
    DIGITAL LINK 40
    - 47
    SDI1 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2, PT
    -
     DZ16K2)48
    - 55
    SDI2 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2) 56
    - 63
    P IN P OFF 64
    - 127
    P IN P execution, USER1 128
    - 135
    P IN P execution, USER2 136
    - 143
    P IN P execution, USER3 144
    - 151
    No operation 152
    - 255
    LENS POSITION No operation
    0
    - 310“Move to the home position” is 
    an operation when [NORMAL] is 
    selected in [HOME POSITION] of 
    the [HOME POSITION]
     screen.
    “Move to the ET
    -
    
    D75LE90 lens 
    standard position” is an operation 
    when [D75LE90] is selected in 
    [HOME POSITION] of the  [HOME 
    POSITION]  screen.
    Move to the home position
    32
    - 63
    Move to the ET
    -
    
    D75LE90 lens 
    standard position
    Load LENS MEMORY 1 64
    - 79
    Load LENS MEMORY 2 80
    - 95
    Load LENS MEMORY 3 96
    - 111
    Load LENS MEMORY 4 112
    - 127
    Load LENS MEMORY 5 128
    - 143
    Load LENS MEMORY 6 144
    - 159
    Load LENS MEMORY 7 160
    - 175
    Load LENS MEMORY 8 176
    - 191
    Load LENS MEMORY 9 192
    - 207
    Load LENS MEMORY 10 208
    - 223
    No operation 224
    - 255
    LENS H SHIFT
    LENS V SHIFT
    LENS FOCUS
    LENS ZOOM Lens adjustment
    (
    -) High speed
    0 - 31
    128 ―
    (
    -) Low speed
    32 - 63
    (
    -) Fine 
    adjustment 64
    - 95
    Operation stop 96
    - 159
    Lens adjustment (+) Fine 
    adjustment
    160
    - 191
    (+) Low speed 192
    - 223
    (+) High speed 224
    - 255
    LENS FUNCTION SELECT 
    (when [1] is selected) No operation
    0
    - 15 0Operate together with LENS 
    CONTROL.
    “Move to the home position” is 
    an operation when [NORMAL] is 
    selected in [HOME POSITION] of 
    the [HOME POSITION]
     screen.
    “Move to the ET
    -
    
    D75LE90 lens 
    standard position” is an operation 
    when [D75LE90] is selected in 
    [HOME POSITION] of the  [HOME 
    POSITION]  screen.
    LENS H SHIFT
    16
    - 31
    LENS V SHIFT 32
    - 47
    LENS FOCUS 48
    - 63
    LENS ZOOM 64
    - 79
    Move to the home position 80
    - 95
    Move to the ET
    -
    
    D75LE90 lens 
    standard position
    No operation 96
    - 255
    LENS CONTROL (when [1] is 
    selected) Lens adjustment
    (
    -) High speed
    0 - 31
    100Operate together with LENS 
    FUNCTION SELECT.
    (
    -) Low speed
    32 - 63
    (
    -) Fine 
    adjustment 64
    - 95
    Operation stop 96
    - 127
    Lens adjustment (+) Fine 
    adjustment
    128
    - 159
    (+) Low speed 160
    - 191
    (+) High speed 192
    - 223
    Execute command action 224
    - 255  
    						
    							Chapter 6 Appendix — Technical information
    ENGLISH - 197
    Control detailsPerformanceParameter Default value Remark
    POWER Standby
    0
    - 63128 ―
    No operation 64
    - 191
    Power on 192
    - 255
    SHUTTER SHUTTER: Open
    0
    - 63128 ―
    No operation 64
    - 191
    SHUTTER: Close 192
    - 255
    FADE-IN
    FADE-OUT
    (when [1] is selected) 0.0s
    0
    - 15255Operate together with 
    CHANNEL1.
    0.5s
    16
    - 31
    1.0s 32
    - 47
    1.5s 48
    - 63
    2.0s 64
    - 79
    2.5s 80
    - 95
    3.0s 96
    - 111
    3.5s 112
    - 127
    4.0s 128
    - 143
    5.0s 144
    - 159
    7.0s 160
    - 175
    10.0s 176
    - 191
    No operation 192
    - 255―
    GEOMETRY OFF
    0
    - 15255 ―
    KEYSTONE
    16
    - 31
    CURVED 32
    - 47
    PC-1 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2) 48
    - 63
    PC-2 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2) 64
    - 79
    PC-3 (Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2) 80
    - 95
    CORNER CORRECTION 96
    - 111
    No operation 112
    - 255
    CUSTOM MASKING OFF
    0
    - 31255(Only for PT
    -
    
    DZ21K2, 
    PT
    -
    
    DS20K2)
    To use PC-1, PC-2, and PC-3, the 
    optional Upgrade Kit (Model No.: 
    ET
    -
    
    UK20) is required.
    PC-1
    32
    - 63
    PC-2 64
    - 95
    PC-3 96
    - 127
    No operation 128
    - 255
    FREEZE No operation
    0
    - 31128 ―
    OFF
    32
    - 95
    No operation 96
    - 159
    ON 160
    - 223
    No operation 224
    - 255
    COLOR
    TINT No operation
    0
    - 310 ―
    Factory default setting
    32
    - 63
    -3164 - 65
    … …
    0 128
    - 129
    … …
    +31 190
    - 191
    No operation 192
    - 255  
    						
    							Chapter 6 Appendix — Technical information
    198 - ENGLISH
    Control detailsPerformanceParameter Default value Remark
    RASTER PATTERN No operation
    0
    - 15
    0 ―
    OFF
    16
    - 31
    WHITE 32
    - 47
    YELLOW 48
    - 63
    CYAN 64
    - 79
    GREEN 80
    - 95
    MAGENTA 96
    - 111
    RED 112
    - 127
    BLUE 128
    - 143
    BLACK 144
    - 159
    USER LOGO 160
    - 175
    No operation 176
    - 255
    ENABLE/DISABLE Disable
    0
    - 1270When “Disable” is set, operations 
    of all channels become 
    unacceptable.
    Enable
    128
    - 255
    Note
     fIf the projector is operated with the remote control or on the control p\
    anel, or by the control command while controlling the projector using 
    the 
    Art-Net function, the setting of the DMX controller or computer application may be dif ferent from the projector status. To reflect the 
    controls of all channels to the projector, set “ENABLE/DISABLE” of channel 11 to “Disable” and then set back to “Enable”.
     f T
    
    o create/register the USER LOGO image, use “Logo Transfer Software” included in the supplied CD-ROM.
    Control commands via LAN
    When web control administrator rights password is set (Protect mode)
    Connecting
    1)  
    Obtain the IP
      address and port number (Initial set value = 1024) of the projector a\
    nd request a 
    connection to the projector.
     f Y
    
    ou can obtain both the IP address and the port number from the menu screen of the projector.
    IP address Obtain from the [NETWORK] menu → [NETWORK STATUS].
    Port number Obtain from the [NETWORK] menu → [NETWORK CONTROL]  → [COMMAND PORT].
    2) Check the response from the projector.
    Data section Blank Mode Blank Random number section Termination 
    symbol
    Command  example “NTCONTROL”
    (ASCII string) ‘ ’
    0x20 ‘1’
    0x31 ‘ ’
    0x20 “zzzzzzzz”
    (ASCII code hex number) (CR)
    0x0d
    Data length 9
      bytes 1
      byte 1   byte 1   byte8
      bytes1
      byte
     fMode: 1 = Protect mode
     fExample: Response during protect mode (random number section is undefined value)
    “NTCONTROL
    
     1 23181e1e” (CR)
    3)
     
    Generate a 32-byte hash value from the following data using MD5 algorith\
    m.
     f “xxxxxx:yyyyy:zzzzzzzz”
    xxxxxx Administrator rights user name for the web control (default user name is “admin1”)
    yyyyy Password of above administrator rights user (default password is “panasonic”)
    zzzzzzzz 8-byte random number obtained in Step  2)  
    						
    							Chapter 6 Appendix — Technical information
    ENGLISH - 199
    Command transmission method
    Transmit using the following command formats.
     r Transmitted data
    Header Data sectionTermination 
    symbol
    Command  example Hash value
    (Refer to “Connecting” above) ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    Data length 32
     
    bytes 1
      byte 1   byteUndefined length 1
      byte
     fExample: Transmission of power supply status acquisition command (hash value is calculated from default user 
    name, password, and acquired random number)
    “dbdd2dabd3d4d68c5dd970ec0c29fa6400QPW” (CR)
     r Received data
    Header Data sectionTermination 
    symbol
    Command  example ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    Data length 1
     
    byte 1
      byte Undefined length 1
      byte
     fExample: The projector is powered on
    “00001” (CR)
     r Error response
    String DetailsTermination 
    symbol
    Message “ERR1” Undefined control command
    (CR)
    0x0d
    “ERR2”
    Out of parameter range
    “ERR3” Busy state or no-acceptable period
    “ERR4” Timeout or no-acceptable period
    “ERR5” Wrong data length
    “ERRA” Password mismatch
    Data length 4
      bytes ―1
      byte
    When web control administrator rights password is not set (Non-protect \
    mode)
    Connecting
    1)  
    Obtain the IP
      address and port number (Initial set value = 1024) of the projector a\
    nd request a 
    connection to the projector.
     f Y
    
    ou can obtain both the IP address and the port number from the menu screen of the projector.
    IP address Obtain from the [NETWORK] menu → [NETWORK STATUS].
    Port number Obtain from the [NETWORK] menu → [NETWORK CONTROL]  → [COMMAND PORT].
    2) Check the response from the projector.
    Data sectionBlankModeTermination 
    symbol
    Command  example “NTCONTROL”
    (ASCII string) ‘ ’
    0x20 ‘0’
    0x30 (CR)
    0x0d
    Data length 9
      bytes 1
      byte1
      byte1
      byte
     fMode: 0 = Non-protect mode
     fExample: Response during non-protect mode
    “NTCONTROL
    
     0” (CR)  
    						
    							Chapter 6 Appendix — Technical information
    200 - ENGLISH
    Command transmission method
    Transmit using the following command formats.
     r Transmitted data
    Header Data sectionTermination 
    symbol
    Command  example ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    Data length 1
     
    byte 1
      byte Undefined length 1
      byte
     fExample: Transmission of power supply status acquisition command
    “00QPW” (CR)
     r Received data
    Header Data sectionTermination 
    symbol
    Command  example ‘0’
    0x30 ‘0’
    0x30 Control command
    (ASCII string) (CR)
    0x0d
    Data length 1
     
    byte 1
      byte Undefined length 1
      byte
     fExample: The power of the projector is in standby status
    “00000” (CR)
     r Error response
    String DetailsTermination 
    symbol
    Message “ERR1” Undefined control command
    (CR)
    0x0d
    “ERR2”
    Out of parameter range
    “ERR3” Busy state or no-acceptable period
    “ERR4” Timeout or no-acceptable period
    “ERR5” Wrong data length
    “ERRA” Password mismatch
    Data length 4
      bytes ―1
      byte  
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic DLP Projector PT-DZ21K2 PT-DS20K2 PT-DW17K2 PT-DZ16K2 Operating Instructions