Page 111
ENGLISH - 111 Chapter 5 Maintenance — Lamp/Temperature/Filter indicators Temperature indicator Indicator status Lighting in red Flashing in red (1 time) Flashing in red (3 times) Status Warm-up status Internal temperature is high (warning)Internal temperature is high (standby warning) The cooling fan has stopped. Cause r f Did you turn on the power when the room temperature was about 0 °C (32 °F)? r f Is the air intake/exhaust port blocked? r f Is the room temperature high? r f Is the filter...
Page 112
112 - ENGLISH Chapter 5 Maintenance — Maintenance/replacement Maintenance/replacement Before maintaining/replacing the unit r f Make sure to turn off the power before maintaining or replacing the unit. ( x pages 41, 43) r f When switching off the projector, make sure to follow the procedures in “Switching off the projector” ( x page 43). Maintenance Outer case Wipe off dirt and dust with a soft, dry cloth. r f If the dirt is persistent, soak the cloth with water and wring it thoroughly before wiping. Dry...
Page 113
ENGLISH - 113 Chapter 5 Maintenance — Maintenance/replacement 2) Dry the air filter unit. r f Let the unit naturally dry off in a well-ventilated place where there is little dust and the unit is protected from direct sunlight. r f Do not dry using drying devices such as dryers. r f When the air filter unit is dry, proceed to the procedure described in “Attaching the air filter unit” ( x page 113). Attaching the air filter unit 1) Attach the air filter unit to the projector. r f The top and bottom of...
Page 114
114 - ENGLISH Chapter 5 Maintenance — Maintenance/replacement Note r f The replacement cycle of the air filter unit varies greatly depending on the usage environment. Lamp unit The lamp unit is a consumable component. Check the lamp usage time in [PROJECT OR SETUP] [STATUS] ( x page 81) in the menu and change the lamp periodically. It is recommended that you request a qualified technician to replace the lamp unit. Consult your dealer . Consult your dealer to purchase a replacement lamp unit (Model No.:...
Page 115
ENGLISH - 115 Chapter 5 Maintenance — Maintenance/replacement 1) Follow the procedures described in “Switching off the projector” ( x page 43) to set the switch to , disconnect the power plug from the power outlet, and wait at least one hour, and then check if the lamp unit has cooled down. 2) Remove the lamp unit cover. i) Use a Phillips screwdriver to loosen the lamp unit cover fixing screw (one screw) until it turns freely, and then open the lamp unit cover in the direction of the arrow. ii)...
Page 116
116 - ENGLISH Chapter 5 Maintenance — Troubleshooting Troubleshooting Review the following points. For details, see the corresponding pages. Problems Points to be checked Page Power does not turn on. r f Is the power plug firmly inserted into the outlet? ― r f Is the switch turned ? 43 r f Is the wall outlet supplying electricity? ― r f Have the circuit breakers tripped? ― r f Is the temperature indicator or the lamp indicator / lit or flashing? 11 0 , 111 r f Is the lamp unit cover securely...
Page 117
ENGLISH - 117 Chapter 6 Appendix This chapter describes specifications and after-sales service for the projector.
Page 118
118 - ENGLISH Chapter 6 Appendix — Technical information Technical information PJLink protocol The network function of this projector supports the PJLink class 1, and the PJLink protocol can be used to perform projector setting and projector status query operations from a computer. Control commands The following table lists the PJLink protocol commands that can be used to control the projector . CommandControl details Notes POWR Power supply control Parameters 0 = Standby 1 = Power on POWR? Power supply...
Page 119
ENGLISH - 119 Chapter 6 Appendix — Technical information Control commands via LAN When WEB control administrator rights password is set (Protect mode) Connection method 1) Obtain the IP address and port number (Initial set value = 1024) of the projector and request for a connection to the projector. r f You can obtain both the IP address and the port number from the menu screen of the projector. IP address Obtain from the main menu → [NETWORK] → [NETWORK STATUS]. Port number Obtain from the main...
Page 120
120 - ENGLISH Chapter 6 Appendix — Technical information r r Error response Error message Termination symbol “ERR1” Undefined control command (CR) 0x0d “ERR2” Out of parameter range “ERR3” Busy state or no-acceptable period “ERR4” Timeout or no-acceptable period “ERR5” Wrong data length “ERRA” Password mismatch 4 bytes 1 byte When WEB control administrator rights password is not set (Non-protect \ mode) Connection method 1) Obtain the IP address and port number (Initial set value = 1024) of the...