Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 300 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Section 300-Installation Chapter 7 - Specifications 576-13-300 DBS 576 (USA), issued 6/2/98 7-7 Cabling Specifications Table 7-9. Maximum Cabling Distances Table 7-10. Voice Path from KTELS to DBS 576 Table 7-11. Data Communication Ports Note If a TAPI box or Voice Response Telephone Adapter is installed with the telephone, the measured resistance must be less than 20 Ohms and the maximum cabling distance reduced in half compared to a standard key telephone. Loop Type Resistance Resistance Cable Gauge (AWG)Maximum Cabling Length in Feet (distance from the DBS 576) Key Telephone, EM/24 See note40 Ohms 22 1239 24 779 26 490 DSS/72 20 Ohms 22 619 24 390 26 245 SLT 100 Ohms 22 3097 24 1948 26 1225 Doorphone (Loop between the DBS and Doorphone Adapters)10 Ohms 22 309 24 194 26 122 Doorphone (Loop between the Doorphone Adapter and the Doorphone)10 Ohms 22 1239 24 779 26 490 Channel Speed Overall communications path 256 kbps D-channel data 16 kbps B-channel data 64 kbps Port Parameters Serial Port 1 Interface RS232-C Baud rate 300, 600, 1200, 2400, 4800, 9600 Bps Parity Even, odd, none Stop bit length 2 or 1 Data bit length 7 or 8 Maintenance (Built-in) Baud rate 300 Stop bit length 1 Data bit length 8 Parity None
Chapter 7 - Specifications Section 300-Installation 7-8 DBS 576 (USA), issued 6/2/98 576-13-300 Signaling Characteristics Table 7-12. Signaling to CO Table 7-13. Transmission Specifications Table 7-14. DTMF Frequencies Serial Port 2 Interface RS232-C Baud rate 300, 600, 1200, 2400, 4800, 9600 Bps Parity Even, odd, none Stop bit length 2 or 1 Data bit length 7 or 8 Item Specification Dial pulse 8 to 11 pulses per second Break ratio 58 to 64% Minimum pause 0.7 to 1.0 seconds Trunk start Loop or ground start Item Specification Impedance 600 Ohms Overload level 600 Ohms Insertion Loss CO trunk to analog station 0 dB Analog station to CO trunk 0 dB CO trunk to digital station 0 dB Digital station to CO trunk 0 dB Digital station to digital station 6 dB Digital station to analog station 6 dB Analog station to digital station 6 dB Analog station to analog station 6 dB Digit Frequency (Hz) 1 700 + 1200 2 700 + 1340 3 700 + 1480 4 760 + 1200 5 760 + 1340 6 760 + 1480 7 860 + 1200 8 860 + 1340 9 860 + 1480 0 940 + 1340 * 940 + 1200 # 940 + 1480 Port Parameters
Section 300 - InstallationIndex 576-13-300 DBS 576 (USA), issued 6/2/98 Index-i Numerics -48 Volt Power Supply (VB-44022) 3-11, 4-20 A About This Manual xv ACD card 6-14 Additional Cabinets 4-1 AEC/8 card 5-39 Analog extensions 5-39 API 6-16 API card (VB-44131) 2-47 Application Interface (API) 6-16 B Background Music (BGM) 6-2 Battery Backup (VB-44025) 3-9, 4-19 Building Block Method (floor-mounting) Installation (576-port example shown) 4-4 Building Block Method (wall-mounting) Installation (576-port example shown) 4-7 C Cabinet Configurations 2-3 Cabinet Description 2-1 Cabinet Installation 3-1 Cabinet installation wall mounting mounting illustration 3-7 Cabinets Installing Additional 4-1 Call Logging Device 6-10 Card Descriptions 2-5 Card Installation 3-13, 4-29 Card Installation Position 4-33 CBL card (VB-44451) Building Block card 2-13 CBLDBS card (VB-44452) Connection Cable card-DBS 2-14 Circuit Card Configuration 2-4 Circuit Cards 2-4 Cleaning 1-5 Conference Card 4-37 Connecting the Systems 4-22, 4-29 CPC288 card (VB-444201) 2-7 CPC576 card (VB-444301) 2-9 CPC96 card (VB-44410 2-5 CPC96, CPC288, CPC576 Card 6-1 D DEC/8 card 5-31, 5-34 DID Requirements 1-3 DID Trunks 5-14 DIDTR 8 card (VB-44520) DID Trunk Card 2-26 DIDTR/8 card 5-14 Digital Extensions 5-31 Doorphone Adaptor 6-23 DSS 6-20 E E&M Tie Line Trunks 5-17 E&M/4 card 5-17 E&M/4 card (VB-44560) E&M Trunk Card 2-27 EM24 6-21 Environmental Requirements 1-4 EXT MDF card (VB-44611) Extension MDF Interface Card 2-16 Extension MDF Interface Card 5-29 Extensions 5-28 F FCC information network address signaling code 1-1 registration number 1-1 ringer equivalence 1-1 FCC Requirements 1-1 Floor Mounting Installation 3-6 Front Cover 3-3 Index
Index-ii DBS 576 (USA), issued 6/2/98 576-13-700 IndexSection 700 - Operation G General Requirements 1-1 Grounding 3-8 I Installation wall mounting cabinet illustration 3-7 Installation Location 3-1, 4-1 Installing Additional Cabinets 4-1 Installing Switch Box 4-12 Installing Switch Boxes (VB-44023) 4-11 Installing the Building Block System 4-1 K Key Phone Wall Mounting 5-48 L LGTRK / 8 card (VB-44511) Loop Start/Ground Start Trunk Card 2-24 LGTRK/8 card 5-10 Loop-Start Trunks 5-6 Loop-Start/Ground Start Trunks 5-10 LTRK / 8 card (VB-44510) Loop Start Trunk Card 2-21, 2-23 LTRK/8 card 5-6 M Maintenance Switches 5-1 Making an RS-232C Cable 6-10 Marks Used in This Manual xvi MDF-CO card 5-4 MDF-EXT card 5-29 MIS Report Output 6-14 Model Numbers 1-1 Music-On-Hold (MOH) 6-1 N Network address signaling code 1-1 O Optimization of Card Installation 4-37 Output Format 6-12 P Paging 6-4 PC Customization Tool 6-7 Peripheral Equipment 6-1 Point to Multi-point connection 5-43 Power Failure Transfer 6-26 PRI/23 card 5-22, 5-45 PRI/23 card (VB-44540) PRI Card 2-30 PRI/23/T1 Card 4-36 R Registration number 1-1 Removing AC cables 4-12 Removing and Replacing Covers 3-2 Removing the front cover 3-3 Removing the side cover 3-4 Removing the top cover 3-5 Replacing the Backup Battery of CPC card 6-29 Replacing the front cover 3-3 Replacing the side cover 3-4 Replacing the top cover 3-5 Requirements 1-1 Restriction on Number of Cards 4-36 Ringer equivalence number 1-1 S SBRI/4 card 5-42 SCC card 6-2, 6-4, 6-7, 6-10 SCC card (VB-44181) Service Control Card 2-19 Setting CBLDBS ID Numbers 4-31 Setting ID No. of Additional Cabinets 4-27 Specifications 7-1 S-Point ISDN Interface (SBRI) 5-42 S-point ISDN Primary Rate Interface (PRI) 5-45 SYNC Package (VB-44460) SYNC Package/Network Unit 2-18 System Overview 2-1
Section 300 - InstallationIndex 576-13-300 DBS 576 (USA), issued 6/2/98 Index-iii T T1 card 5-25 T1 Interface 5-25 T1 Requirements 1-4 TAPI Adaptor 6-22 TBRI/4 card 5-19 TBRI/4 card (VB-44530) BRI Card (T-point) 2-28 Top Cover (CAB96 only) 3-5 T-Point ISDN Interface (TBRI) 5-19 T-Point ISDN Primary Rate Interface (PRI) 5-22 TRK MDF card (VB-44512) Trunk MDF Interface Card 2-17 Trunk MDF Interface Card 5-4 Trunks 5-3 Trunks and Extensions 5-1 TSW288 card (VB-444201) 2-11 TSW576 card (VB-444302 2-12 V VB-44131 2-47 Voice Recognition Adaptor 6-18 VPU/4 card (VB-44160) 4-voice Processing card 2-43 W Wall mounting cabinets mounting illustration 3-7 Wall Mounting Installation 3-7
Index-iv DBS 576 (USA), issued 6/2/98 576-13-700 IndexSection 700 - Operation