    Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 300 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Section 300-Installation Chapter 6. Peripheral Equipment
    576-13-300 DBS 576 (USA), issued 6/2/98 6-27 
    Figure 6-23. Power Failure Unit cable punch-out plate and wall mounting
    4.  Connect the pin3 of CN5 (FG) to the earth.
    5.  Connect the SLTs to the AEC extension ports on the PFU.
    6.  Connect the trunks from the DBS 576 to the PFU.
    7.  Connect the AEC ports from the DBS 576 to the PFU.
    When a power failure occurs, AEC/8 card A line is switched to trunk 
    A line, AEC/8 card B line is switched to trunk B line, and so on.
    8.  Connect the +24V and GND terminals from the DBS 576 power unit to the PFU.
    9.  Install the cover on the PFU. 
    						
    							Chapter 6. Peripheral Equipment Section 300-Installation
    6-28 DBS 576 (USA), issued 6/2/98 576-13-300
    Figure 6-24. Power Failure Unit connections 
    						
    							Section 300-Installation Chapter 6. Peripheral Equipment
    576-13-300 DBS 576 (USA), issued 6/2/98 6-29 
    Replacing the Backup Battery of CPC 
    card
    Guidelines
    • The backup batteries on the CPC96, CPC288, and CPC576 cards backup data 
    such as program settings, speed dialing data, and the date and time. Be sure to 
    replace the backup batteries before they are exhausted.
    Installation
    1.  Connect the new backup battery to the following connectors on the CPC96, 
    CPC288, and CPC576 cards:
    Note:The two connectors on each of these cards are connected in parallel.
    2.  Cut the two tie-wraps using nippers to remove the old backup battery.
    3.  Secure the new backup battery using the two tie wraps.
    Note:Secure the battery so that it cannot move. CAUTION:
    • Turn the power switch and make certain the AC cable is before replacing 
    the backup battery.
    • The backup battery will last about 7 years. Be sure to replace the battery 
    before it is exhausted.
    Card Connector
    CPC96 CN6 or CN7
    CPC288 CN6 or CN7
    CPC576 CN5 or CN6
    CPC96, CPC288, CPC576 Card 
    						
    							Section 300-Installation Chapter 6. Peripheral Equipment
    576-13-300 DBS 576 (USA), issued 6/2/98 6-30 
    Figure 6-25. Replacing the backup battery of CPC card
    · CPC96 card and CPC288 card
    · CPC576 card
    Note: A clear protective shield is present around the battery. However, this shield is not shown
    to better illustrate the battery position. This will not interfere with the battery replacement. Note: A clear protective shield is present around the battery. However, this shield is not shown
    to better illustrate the battery position. This will not interfere with the battery replacement. 
    						
    							576-13-300 DBS 576 (USA), issued 6/2/98  7-1
    Chapter 7. Specifications
    This chapter lists the specifications of the equipment constituting the DBS 576.
    Note:The following specifications are subject to change without notice.
    Electrical Characteristics
    Table 7-1.  Input Power
    Environmental Requirements
    Table 7-2.  Battery Backup Capacity
    Table 7-3.  Temperature and Humidity Requirements for System Operation 
    (excludes Built-In Voice Mail)
    Table 7-4.  Temperature and Humidity Requirements for Built-in VM
    Equipment Power Requirements
    All DBS 576 Cabinets 120V AC +
     10% 60 Hz
    DBS 576 key telephones 3 watts maximum (powered from the DBS 576)
    System Battery Pack Capacity (with maximum traffic)
    DBS 576 VB-44025 30 minutes
    Environmental Conditions Requirements
    Temperature 32 to 104 degrees F (0 to 40 degrees C)
    Relative Humidity 30 to 90%
    Environmental Conditions Requirements
    Temperature 41 to 95 degrees F (5 to 35 degrees C)
    Relative Humidity 30 to 90% 
    						
    							Chapter 7 - Specifications Section 300-Installation
    7-2 DBS 576 (USA), issued 6/2/98 576-13-300
    Table 7-5.  Dimensions and Weight for Single-Cabinet Systems and Telephones
    Table 7-6.  Resource Maximums
    Base Cabinet Expansion Cabinet
    Dimensions (H x W x D in 
    inches)
    Cabinet 26 3/4” W x 10 7/8” D x 20 5/16” H 
    (including top panel)26 3/4” W x 10 7/8” D x 17 2/16” H 
    (not including top panel)
    VB-44225 4 1/8 x 7 3/8 x 9
    Other key telephones 3 3/4 x 7 3/8 x 9
    DSLT 3 1/8 x 7 3/8 x 9 1/8
    DSS/72 2 15/16 x 4 13/16 x 9 3/16
    EM/24 2 15/16 x 2 3/8 x 9 3/16
    Weight (lbs)
    Cabinet Approximately 44 Approximately 44
    VB-44225 2.3
    Other key telephones 2.2
    DSLT 1.6
    DSS/72 1.2
    EM/24 .95
    System Resources 1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets
    CO line ports 96 192 288 384 480 576
    Station ports 96 192 288 384 480 576
    CO line/Station Speech path 
    switchingnonblocking 
    						
    							Section 300-Installation Chapter 7 - Specifications
    576-13-300 DBS 576 (USA), issued 6/2/98  7-3
    Table 7-7.  Feature Related Capacities
    ResourceMaximum for 
    1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets
    CPU configurationCPC-96 ----- ----- ----- ----- -----
    CPC-288 ----- ----- -----
    CPC-576
    Cabinet connection 1 KSU 2 KSU 3 KSUs 4 KSUs 5 KSUs 6 KSUs
    Loop Start 96 192 288 384 480 576
    Ground Start 96 192 288 384 480 576
    ISDN BRI 48 96 144 192 240 288
    ISDN PRI(8/16/24)369121518
    DID 96 192 288 384 480 576
    T1(8/16/24) 369121518
    E&M 48 96 144 192 240 288
    Analog Ext. 96 192 288 384 480 576
    Digital Ext. 96 192 288 384 480 576
    ISDN BRI 48 96 144 192 240 288
    ISDN PRI 369121518
    EM 24 96 192 288 384 480 576
    DSS 122436486072
    3 Member Conf. X 8111111
    8 Member Conf. X 224681216
    DTMFR Unit 246888
    API Unit 111111
    TSAPI Unit111111
    ACD Unit 111222
    VM/AA Unit 123444
    Traffic Condition 6 OHCS
    Speech Pass Time division PCM method
    MCO Tenant 12 24 36 48 60 72
    MCO Trunk Group 99 99 99 99 99 99
    Max. System Speed Dial 800 800 800 800 800 800
    Max. Personal Speed Dial 20 20 20 20 20 20
    Max. Digits of Speed Dial 24 24 24 24 24 24
    Max. Name Digits of SPD 16 16 16 16 16 16
    Max. Name Digits of PSD777777
    Max. Name Digits of TRK101010101010
    Max. Name Digits of  EXT.101010101010
    Attendant Group 111111
    Max. Attendant Member  20 20 20 20 20 20
    Max. Hunting Group122436486072
    Max. Hunting Member 20 20 20 20 20 20
    External Page port111111
    External Relay Control Port555555
    Message Waiting Set (High)
    (Per Extension)111111 
    						
    							Chapter 7 - Specifications Section 300-Installation
    7-4 DBS 576 (USA), issued 6/2/98 576-13-300
    Message waiting set (Normal)
    (Per Extension)444444
    Max Hot Line Setting202020202020
    Flowing Park 96 192 288 384 480 576
    Ext. Class Of Service Group 16 16 16 16 16 16
    Trk. Class Of Service Group161616161616
    TRS Class 505050505050
    TRS/LCR 10/Leading Dial 100 100 100 100 100 100
    Table TRS/LCR 8 digits 
    Following Digits500 500 500 500 500 500
    LCR Time Pattern 444444
    LCR Time List (Per Time Pat.)505050505050
    LCR Route List 100 100 100 100 100 100
    LCR Dial Modification Pattern505050505050
    Authorization ID 555555
    DID Number Table  96 x 2 192 x 2 288 x 2 384 x 2 480 x2 576 x 2
    ISDN S point DID Table 200 200 200 200 200 200
    Closed Number 150 150 150 150 150 150
    Tandem Exchange Number 50 50 50 50 50 50
    Account Code Max. Digits 10 10 10 10 10 10
    Verified Account Number 500 500 500 500 500 500
    Verified Account Max. Digits444444
    Pickup Group 122436486072
    Max. Paging Group 10 10 10 10 10 10
    Max. Paging Member 72 72 72 72 72 72ResourceMaximum for 
    1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets 
    						
    							Section 300-Installation Chapter 7 - Specifications
    576-13-300 DBS 576 (USA), issued 6/2/98  7-5
    Table 7-8.  Hardware Maximums
    Part No. Description Maximum Quantity For
    
    	
    
    	
    	
    	
    	
    	
    Station Equipment
    VB-44023 Switch Box N/A11122
    VB-44101 Voice Recognition Adaptor 96 192 288 384 480 576
    VB-44210 16-key standard phone with handsfree 
    answerback96 192 288 384 480 576
    VB-44220 22-key standard phone with handsfree 
    answerback96 192 288 384 480 576
    VB-44223 22-key standard phone with LCD display 96 192 288 384 480 576
    VB-44224 22-key speaker phone with LCD display 
    voice recognition capability96 192 288 384 480 576
    VB-44225 22-key speakerphone with large LCD 
    display96 192 288 384 480 576
    VB-44230 34-key speakerphone with handsfree 
    answerback96 192 288 384 480 576
    VB-44231 34-key speakerphone with LCD display 96 192 288 384 480 576
    VB-44310 24-key expansion module (EM24) 48 96 144 192 240 288
    VB-44320 72-key DSS/BLF module (DSS/72) 12 24 36 48 60 72
    VB-44884 7 ft. handset cord 96 192 288 384 480 576
    VB-44885 15 ft. handset cord 96 192 288 384 480 576
    VB-44886 25 ft. handset cord 96 192 288 384 480 576
    VB-44890 K-type handset 96 192 288 384 480 576
    Common Equipment
    VB-44120 Conference Card 8-party24681216
    VB-44181 Service circuit card (SCC)111111
    VB-44410 CPC-96 call processor card 1 N/A N/A N/A N/A N/A
    VB-
    444201CPC-288 call processor card  111N/AN/AN/A
    VB-
    444202Time switch card TSW288 111N/AN/AN/A
    VB-
    444301CPC-576 call processor card  111111
    VB-
    444302Time switch card TSW576 111111
    VB-44451 CBL (Building block expansion card - 
    interface card for additional cabinet)N/A12345
    VB-44452 CBL DBS (Connection cable card - DBS)
    Note: 1 per DBS cabinet N/A12222
    Telephone Company Interfaces
    VB-43551 8-circuit Caller ID daughter board  12 24 36 48 60 72
    VB-44460 Sync Unit111111
    VB-44510 8-port loop-start trunk card (L-TRK/8) 12 24 36 48 60 72
    VB-44511 8-port ground-start trunk card (G-TRK/8) 12 24 36 48 60 72
    VB-44512 Trunk MDF connector 5 10 15 20 25 30
    VB-44520 Direct-inward-dialing trunk card (DID) 12 24 36 48 60 72 
    						
    							Chapter 7 - Specifications Section 300-Installation
    7-6 DBS 576 (USA), issued 6/2/98 576-13-300
    Note: These maximum are based on overall CO line capacities and do not allow for CO lines used for outside lines.
    VB-44530 Basic Rate Interface (BRI) 12 24 36 48 60 72
    VB-44540 Primary Rate Interface (PRI)369121518
    VB-44550 T-1 Interface369121518
    VB-44560 E&M tie line trunk card 12 24 36 42 60 72
    Station Interfaces
    VB-44110 DTMF signal receiver for 8 SLT lines (MFR/
    8)246888
    VB-44610 8-port digital extension card (DEC) 12 24 36 48 60 72
    VB-44611 Extension MDF connector 5 10 15 20 25 30
    VB-
    4462308-port analog extension card (AEC) 12 24 36 48 60 72
    VB-44630 Basic Rate Interface (BRI) 12 24 36 48 60 72
    VB-
    446540Primary Rate Interface (PRI)I 369121518
    Optional Equipment
    VB-43703 4-line power failure unit 24 48 72 96 120 144
    VB-44025 Built-in system backup battery kit (2 
    batteries per kit)123456
    VB-44130 Application processor interface API111111
    VB-44140 Built-in ACD111222
    VB-44150 Voice processing card/8 (VM only)246888
    VB-44160 Voice processing card/4 (ACD or VM)2468910
    VB-44170 Built-in VM123444
    VB-44330 PC Attendant (up to 96 EXT) TBD TBD TBD TBD TBD TBD
    VB-44331 PC Attendant (up to 384 EXT) TBD TBD TBD TBD TBD TBD
    VB-44332 PC Phone 96 192 288 384 480 576
    VB-TBDPC Customize Tool 111111Part No. Description Maximum Quantity For
    
    	
    
    	
    	
    	
    	
    	 
    						