Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 300 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-27 Figure 6-23. Power Failure Unit cable punch-out plate and wall mounting 4. Connect the pin3 of CN5 (FG) to the earth. 5. Connect the SLTs to the AEC extension ports on the PFU. 6. Connect the trunks from the DBS 576 to the PFU. 7. Connect the AEC ports from the DBS 576 to the PFU. When a power failure occurs, AEC/8 card A line is switched to trunk A line, AEC/8 card B line is switched to trunk B line, and so on. 8. Connect the +24V and GND terminals from the DBS 576 power unit to the PFU. 9. Install the cover on the PFU.
Chapter 6. Peripheral Equipment Section 300-Installation 6-28 DBS 576 (USA), issued 6/2/98 576-13-300 Figure 6-24. Power Failure Unit connections
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-29 Replacing the Backup Battery of CPC card Guidelines • The backup batteries on the CPC96, CPC288, and CPC576 cards backup data such as program settings, speed dialing data, and the date and time. Be sure to replace the backup batteries before they are exhausted. Installation 1. Connect the new backup battery to the following connectors on the CPC96, CPC288, and CPC576 cards: Note:The two connectors on each of these cards are connected in parallel. 2. Cut the two tie-wraps using nippers to remove the old backup battery. 3. Secure the new backup battery using the two tie wraps. Note:Secure the battery so that it cannot move. CAUTION: • Turn the power switch and make certain the AC cable is before replacing the backup battery. • The backup battery will last about 7 years. Be sure to replace the battery before it is exhausted. Card Connector CPC96 CN6 or CN7 CPC288 CN6 or CN7 CPC576 CN5 or CN6 CPC96, CPC288, CPC576 Card
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-30 Figure 6-25. Replacing the backup battery of CPC card · CPC96 card and CPC288 card · CPC576 card Note: A clear protective shield is present around the battery. However, this shield is not shown to better illustrate the battery position. This will not interfere with the battery replacement. Note: A clear protective shield is present around the battery. However, this shield is not shown to better illustrate the battery position. This will not interfere with the battery replacement.
576-13-300 DBS 576 (USA), issued 6/2/98 7-1 Chapter 7. Specifications This chapter lists the specifications of the equipment constituting the DBS 576. Note:The following specifications are subject to change without notice. Electrical Characteristics Table 7-1. Input Power Environmental Requirements Table 7-2. Battery Backup Capacity Table 7-3. Temperature and Humidity Requirements for System Operation (excludes Built-In Voice Mail) Table 7-4. Temperature and Humidity Requirements for Built-in VM Equipment Power Requirements All DBS 576 Cabinets 120V AC + 10% 60 Hz DBS 576 key telephones 3 watts maximum (powered from the DBS 576) System Battery Pack Capacity (with maximum traffic) DBS 576 VB-44025 30 minutes Environmental Conditions Requirements Temperature 32 to 104 degrees F (0 to 40 degrees C) Relative Humidity 30 to 90% Environmental Conditions Requirements Temperature 41 to 95 degrees F (5 to 35 degrees C) Relative Humidity 30 to 90%
Chapter 7 - Specifications Section 300-Installation 7-2 DBS 576 (USA), issued 6/2/98 576-13-300 Table 7-5. Dimensions and Weight for Single-Cabinet Systems and Telephones Table 7-6. Resource Maximums Base Cabinet Expansion Cabinet Dimensions (H x W x D in inches) Cabinet 26 3/4” W x 10 7/8” D x 20 5/16” H (including top panel)26 3/4” W x 10 7/8” D x 17 2/16” H (not including top panel) VB-44225 4 1/8 x 7 3/8 x 9 Other key telephones 3 3/4 x 7 3/8 x 9 DSLT 3 1/8 x 7 3/8 x 9 1/8 DSS/72 2 15/16 x 4 13/16 x 9 3/16 EM/24 2 15/16 x 2 3/8 x 9 3/16 Weight (lbs) Cabinet Approximately 44 Approximately 44 VB-44225 2.3 Other key telephones 2.2 DSLT 1.6 DSS/72 1.2 EM/24 .95 System Resources 1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets CO line ports 96 192 288 384 480 576 Station ports 96 192 288 384 480 576 CO line/Station Speech path switchingnonblocking
Section 300-Installation Chapter 7 - Specifications 576-13-300 DBS 576 (USA), issued 6/2/98 7-3 Table 7-7. Feature Related Capacities ResourceMaximum for 1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets CPU configurationCPC-96 ----- ----- ----- ----- ----- CPC-288 ----- ----- ----- CPC-576 Cabinet connection 1 KSU 2 KSU 3 KSUs 4 KSUs 5 KSUs 6 KSUs Loop Start 96 192 288 384 480 576 Ground Start 96 192 288 384 480 576 ISDN BRI 48 96 144 192 240 288 ISDN PRI(8/16/24)369121518 DID 96 192 288 384 480 576 T1(8/16/24) 369121518 E&M 48 96 144 192 240 288 Analog Ext. 96 192 288 384 480 576 Digital Ext. 96 192 288 384 480 576 ISDN BRI 48 96 144 192 240 288 ISDN PRI 369121518 EM 24 96 192 288 384 480 576 DSS 122436486072 3 Member Conf. X 8111111 8 Member Conf. X 224681216 DTMFR Unit 246888 API Unit 111111 TSAPI Unit111111 ACD Unit 111222 VM/AA Unit 123444 Traffic Condition 6 OHCS Speech Pass Time division PCM method MCO Tenant 12 24 36 48 60 72 MCO Trunk Group 99 99 99 99 99 99 Max. System Speed Dial 800 800 800 800 800 800 Max. Personal Speed Dial 20 20 20 20 20 20 Max. Digits of Speed Dial 24 24 24 24 24 24 Max. Name Digits of SPD 16 16 16 16 16 16 Max. Name Digits of PSD777777 Max. Name Digits of TRK101010101010 Max. Name Digits of EXT.101010101010 Attendant Group 111111 Max. Attendant Member 20 20 20 20 20 20 Max. Hunting Group122436486072 Max. Hunting Member 20 20 20 20 20 20 External Page port111111 External Relay Control Port555555 Message Waiting Set (High) (Per Extension)111111
Chapter 7 - Specifications Section 300-Installation 7-4 DBS 576 (USA), issued 6/2/98 576-13-300 Message waiting set (Normal) (Per Extension)444444 Max Hot Line Setting202020202020 Flowing Park 96 192 288 384 480 576 Ext. Class Of Service Group 16 16 16 16 16 16 Trk. Class Of Service Group161616161616 TRS Class 505050505050 TRS/LCR 10/Leading Dial 100 100 100 100 100 100 Table TRS/LCR 8 digits Following Digits500 500 500 500 500 500 LCR Time Pattern 444444 LCR Time List (Per Time Pat.)505050505050 LCR Route List 100 100 100 100 100 100 LCR Dial Modification Pattern505050505050 Authorization ID 555555 DID Number Table 96 x 2 192 x 2 288 x 2 384 x 2 480 x2 576 x 2 ISDN S point DID Table 200 200 200 200 200 200 Closed Number 150 150 150 150 150 150 Tandem Exchange Number 50 50 50 50 50 50 Account Code Max. Digits 10 10 10 10 10 10 Verified Account Number 500 500 500 500 500 500 Verified Account Max. Digits444444 Pickup Group 122436486072 Max. Paging Group 10 10 10 10 10 10 Max. Paging Member 72 72 72 72 72 72ResourceMaximum for 1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets
Section 300-Installation Chapter 7 - Specifications 576-13-300 DBS 576 (USA), issued 6/2/98 7-5 Table 7-8. Hardware Maximums Part No. Description Maximum Quantity For Station Equipment VB-44023 Switch Box N/A11122 VB-44101 Voice Recognition Adaptor 96 192 288 384 480 576 VB-44210 16-key standard phone with handsfree answerback96 192 288 384 480 576 VB-44220 22-key standard phone with handsfree answerback96 192 288 384 480 576 VB-44223 22-key standard phone with LCD display 96 192 288 384 480 576 VB-44224 22-key speaker phone with LCD display voice recognition capability96 192 288 384 480 576 VB-44225 22-key speakerphone with large LCD display96 192 288 384 480 576 VB-44230 34-key speakerphone with handsfree answerback96 192 288 384 480 576 VB-44231 34-key speakerphone with LCD display 96 192 288 384 480 576 VB-44310 24-key expansion module (EM24) 48 96 144 192 240 288 VB-44320 72-key DSS/BLF module (DSS/72) 12 24 36 48 60 72 VB-44884 7 ft. handset cord 96 192 288 384 480 576 VB-44885 15 ft. handset cord 96 192 288 384 480 576 VB-44886 25 ft. handset cord 96 192 288 384 480 576 VB-44890 K-type handset 96 192 288 384 480 576 Common Equipment VB-44120 Conference Card 8-party24681216 VB-44181 Service circuit card (SCC)111111 VB-44410 CPC-96 call processor card 1 N/A N/A N/A N/A N/A VB- 444201CPC-288 call processor card 111N/AN/AN/A VB- 444202Time switch card TSW288 111N/AN/AN/A VB- 444301CPC-576 call processor card 111111 VB- 444302Time switch card TSW576 111111 VB-44451 CBL (Building block expansion card - interface card for additional cabinet)N/A12345 VB-44452 CBL DBS (Connection cable card - DBS) Note: 1 per DBS cabinet N/A12222 Telephone Company Interfaces VB-43551 8-circuit Caller ID daughter board 12 24 36 48 60 72 VB-44460 Sync Unit111111 VB-44510 8-port loop-start trunk card (L-TRK/8) 12 24 36 48 60 72 VB-44511 8-port ground-start trunk card (G-TRK/8) 12 24 36 48 60 72 VB-44512 Trunk MDF connector 5 10 15 20 25 30 VB-44520 Direct-inward-dialing trunk card (DID) 12 24 36 48 60 72
Chapter 7 - Specifications Section 300-Installation 7-6 DBS 576 (USA), issued 6/2/98 576-13-300 Note: These maximum are based on overall CO line capacities and do not allow for CO lines used for outside lines. VB-44530 Basic Rate Interface (BRI) 12 24 36 48 60 72 VB-44540 Primary Rate Interface (PRI)369121518 VB-44550 T-1 Interface369121518 VB-44560 E&M tie line trunk card 12 24 36 42 60 72 Station Interfaces VB-44110 DTMF signal receiver for 8 SLT lines (MFR/ 8)246888 VB-44610 8-port digital extension card (DEC) 12 24 36 48 60 72 VB-44611 Extension MDF connector 5 10 15 20 25 30 VB- 4462308-port analog extension card (AEC) 12 24 36 48 60 72 VB-44630 Basic Rate Interface (BRI) 12 24 36 48 60 72 VB- 446540Primary Rate Interface (PRI)I 369121518 Optional Equipment VB-43703 4-line power failure unit 24 48 72 96 120 144 VB-44025 Built-in system backup battery kit (2 batteries per kit)123456 VB-44130 Application processor interface API111111 VB-44140 Built-in ACD111222 VB-44150 Voice processing card/8 (VM only)246888 VB-44160 Voice processing card/4 (ACD or VM)2468910 VB-44170 Built-in VM123444 VB-44330 PC Attendant (up to 96 EXT) TBD TBD TBD TBD TBD TBD VB-44331 PC Attendant (up to 384 EXT) TBD TBD TBD TBD TBD TBD VB-44332 PC Phone 96 192 288 384 480 576 VB-TBDPC Customize Tool 111111Part No. Description Maximum Quantity For