    Have a look at the manual Panasonic Digital Business System 576 Technical Manual Section 300 online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Section 300-Installation Chapter 5 - Trunks and Extensions
    576-13-300 DBS 576 (USA), issued 6/2/98  5-47
    Figure 5-18. Connection of S-point ISDN Primary Rate Interface (PRI) 
    						
    							Chapter 5 - Trunks and Extensions Section 300-Installation
    5-48 DBS 576 (USA), issued 6/2/98 576-13-300
    Key Phone Wall Mounting
    Guidelines
    • DBS 576 key phones can be mounted on the wall using the wall mounting adapter 
    on the bottom of the phone.
    Installation
    1.  Remove the wall mounting adapter from the bottom of the phone taking care not 
    to damage the adapter hooks.
    2.  Rotate the wall mounting adapter by 180 degrees, then slot it into the two 
    guides.
    3.  Remove the handset guide, rotate it by 180 degrees, and replace it.
    4.  Insert two screws in the wall.
    5.  Hook the two mounting holes on the bottom of the phone onto the two screws in 
    the wall. 
    						
    							Section 300-Installation Chapter 5 - Trunks and Extensions
    576-13-300 DBS 576 (USA), issued 6/2/98  5-49
    Figure 5-19. Wall mounting of phone 
    						
    							Chapter 5 - Trunks and Extensions Section 300-Installation
    5-50 DBS 576 (USA), issued 6/2/98 576-13-300 
    						
    							576-13-300 DBS 576 (USA), issued 6/2/98  6-1
    Chapter 6. Peripheral Equipment
    This chapter describes how to install and connect DSS, doorphone adaptors, other 
    peripheral equipment, and replacing the backup battery of CPC card.
    Music-On-Hold (MOH)
    Guidelines
    • A music source such as a CD player or tape recorder can be connected to the 
    MOH input of a CPC96, CPC288, or CPC576 card installed in the CPC slots of 
    the cabinet to provide music-on-hold (MOH).
    • CPC96, CPC288, and CPC576 cards cannot be installed and removed while the 
    cabinet is operating. First, turn the power off.
    • The maximum input impedance of the MOH input (CN4: RCA) is 10k
     Ohms. The 
    maximum input signal level is -10dB.
    Installation
    1.  Connect one end of an RCA pin cable (2-core shielded cable) to the CN4 (RCA) 
    connector on the CPC96, CPC288, or CPC576 card.
    2.  Connect the other end of the RCA pin cable to the output (AUX) of a music 
    source such as a CD player or tape recorder.
    Fit the appropriate connector (RCA or mini-plug, etc.) as required to the 
    end of the RCA pin cable to suit your music source.
    CPC96, CPC288, CPC576 Card 
    						
    							Chapter 6. Peripheral Equipment Section 300-Installation
    6-2 DBS 576 (USA), issued 6/2/98 576-13-300
    Figure 6-1. Installation of music-on-hold source
    Background Music (BGM)
    Guidelines
    • A music source such as a CD player or tape recorder can be connected to the 
    BGM input (RCA) of an SCC card installed in one of the optional card slots of the 
    cabinet to provide background music (BGM).
    • SCC cards cannot be installed and removed while the cabinet is operating. First, 
    turn the power off.
    • If an FM radio is connected as a music source, it must be located at least 16.5 ft. 
    (5m) from the cabinet.
    • The maximum input impedance of the BGM input (CN4: RCA) is 10k
     Ohms. The 
    maximum input signal level is -10dB.
    SCC card 
    						
    							Section 300-Installation Chapter 6. Peripheral Equipment
    576-13-300 DBS 576 (USA), issued 6/2/98 6-3 
    Installation
    1.  Install the SCC card in an available optional card slot.
    2.  Connect one end of an RCA pin cable (2-core shielded cable) to the CN4 (RCA) 
    connector on the SCC card.
    3.  Connect the other end of the RCA pin cable to the output (AUX) of a music 
    source such as a CD player or tape recorder.
    Fit the appropriate connector (RCA or mini-plug, etc.) as required to the 
    end of the RCA pin cable to suit your music source.
    Figure 6-2. Installation of background music source 
    						
    							Chapter 6. Peripheral Equipment Section 300-Installation
    6-4 DBS 576 (USA), issued 6/2/98 576-13-300
    Paging
    Guidelines
    • Paging can be performed by connecting a paging amplifier, relays, and speakers 
    to an SCC card installed in one of the optional card slots.
    • SCC cards cannot be installed and removed while the cabinet is operating. First, 
    turn the power off.
    • The paging amplifier, relays, and speakers are not provided with the DBS 576 and 
    must therefore be purchased separately.
    • Table 6-1 shows the pinout of the external connector (CN3) of the SCC card.
    Table 6-1.  Pinout of external connector (CN3) of SCC cardCAUTION:
    • Turn the power switch and the external breaker OFF, and disconnect the 
    AC cable before installing the Paging equipment.
    Pin No. Signal Description
    1 GND Signal ground
    2-
    3-
    4 S5 External paging control output 5
    (withstand voltage: 30V)
    5 S4 External paging control output 4
    (withstand voltage: 30V)
    6 S3 External paging control output 3 
    (withstand voltage: 30V)
    7 S2 External paging control output 2 
    (withstand voltage: 30V)
    8 S1 External paging control output 1
    (withstand voltage: 30V)
    9 MB External paging control output B
    (relay loop make contact: maximum current: 2A)
    10 MA External paging control output A (relay loop make contact: maximum current: 
    2A)
    11 B External paging I/O B
    12 A External paging I/O A
    SCC card 
    						
    							Section 300-Installation Chapter 6. Peripheral Equipment
    576-13-300 DBS 576 (USA), issued 6/2/98 6-5 
    Installation
    1.  Set SW2 on the SCC card to match the input impedance of the connected device. 
    See Table 6-2 for SW2 settings.
    Table 6-2.  Settings of SW2 on SCC card
    2.  Install the SCC card in an available optional card slot.
    3.  Prepare a cable with a DDK connector and connect one end of it to CN3.
    4.  Connect the other end of the cable to the paging amplifier, relays, and speakers.
    Switch No. Position Setting
    SW2 ON External paging device input impedance: 600 Ohms
    OFF External paging device input impedance: high impedance (default 
    when shipped) 
    						
    							Chapter 6. Peripheral Equipment Section 300-Installation
    6-6 DBS 576 (USA), issued 6/2/98 576-13-300
    Figure 6-3. Connection of paging device 
    						