Page 201
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-27 Figure 6-23. Power Failure Unit cable punch-out plate and wall mounting 4. Connect the pin3 of CN5 (FG) to the earth. 5. Connect the SLTs to the AEC extension ports on the PFU. 6. Connect the trunks from the DBS 576 to the PFU. 7. Connect the AEC ports from the DBS 576 to the PFU. When a power failure occurs, AEC/8 card A line is switched to trunk A line, AEC/8 card B line is switched to trunk B...
Page 202
Chapter 6. Peripheral Equipment Section 300-Installation 6-28 DBS 576 (USA), issued 6/2/98 576-13-300 Figure 6-24. Power Failure Unit connections
Page 203
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-29 Replacing the Backup Battery of CPC card Guidelines • The backup batteries on the CPC96, CPC288, and CPC576 cards backup data such as program settings, speed dialing data, and the date and time. Be sure to replace the backup batteries before they are exhausted. Installation 1. Connect the new backup battery to the following connectors on the CPC96, CPC288, and CPC576 cards: Note:The two connectors...
Page 204
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-30 Figure 6-25. Replacing the backup battery of CPC card · CPC96 card and CPC288 card · CPC576 card Note: A clear protective shield is present around the battery. However, this shield is not shown to better illustrate the battery position. This will not interfere with the battery replacement. Note: A clear protective shield is present around the battery. However, this shield is not shown to better...
Page 205
576-13-300 DBS 576 (USA), issued 6/2/98 7-1 Chapter 7. Specifications This chapter lists the specifications of the equipment constituting the DBS 576. Note:The following specifications are subject to change without notice. Electrical Characteristics Table 7-1. Input Power Environmental Requirements Table 7-2. Battery Backup Capacity Table 7-3. Temperature and Humidity Requirements for System Operation (excludes Built-In Voice Mail) Table 7-4. Temperature and Humidity Requirements for Built-in VM...
Page 206
Chapter 7 - Specifications Section 300-Installation 7-2 DBS 576 (USA), issued 6/2/98 576-13-300 Table 7-5. Dimensions and Weight for Single-Cabinet Systems and Telephones Table 7-6. Resource Maximums Base Cabinet Expansion Cabinet Dimensions (H x W x D in inches) Cabinet 26 3/4” W x 10 7/8” D x 20 5/16” H (including top panel)26 3/4” W x 10 7/8” D x 17 2/16” H (not including top panel) VB-44225 4 1/8 x 7 3/8 x 9 Other key telephones 3 3/4 x 7 3/8 x 9 DSLT 3 1/8 x 7 3/8 x 9 1/8 DSS/72 2 15/16 x 4...
Page 207
Section 300-Installation Chapter 7 - Specifications 576-13-300 DBS 576 (USA), issued 6/2/98 7-3 Table 7-7. Feature Related Capacities ResourceMaximum for 1 Cabinet 2 Cabinets 3 Cabinets 4 Cabinets 5 Cabinets 6 Cabinets CPU configurationCPC-96 ----- ----- ----- ----- ----- CPC-288 ----- ----- ----- CPC-576 Cabinet connection 1 KSU 2 KSU 3 KSUs 4 KSUs 5 KSUs 6 KSUs Loop Start 96 192 288 384 480 576 Ground Start 96 192 288 384 480 576 ISDN BRI 48 96 144 192 240 288 ISDN PRI(8/16/24)369121518 DID 96 192...
Page 208
Chapter 7 - Specifications Section 300-Installation 7-4 DBS 576 (USA), issued 6/2/98 576-13-300 Message waiting set (Normal) (Per Extension)444444 Max Hot Line Setting202020202020 Flowing Park 96 192 288 384 480 576 Ext. Class Of Service Group 16 16 16 16 16 16 Trk. Class Of Service Group161616161616 TRS Class 505050505050 TRS/LCR 10/Leading Dial 100 100 100 100 100 100 Table TRS/LCR 8 digits Following Digits500 500 500 500 500 500 LCR Time Pattern 444444 LCR Time List (Per Time Pat.)505050505050 LCR...
Page 209
Section 300-Installation Chapter 7 - Specifications 576-13-300 DBS 576 (USA), issued 6/2/98 7-5 Table 7-8. Hardware Maximums Part No. Description Maximum Quantity For Station Equipment VB-44023 Switch Box N/A11122 VB-44101 Voice Recognition Adaptor 96 192 288 384 480 576 VB-44210 16-key standard phone with handsfree answerback96 192 288 384 480 576 VB-44220 22-key standard phone with handsfree answerback96 192 288 384 480 576 VB-44223 22-key...
Page 210
Chapter 7 - Specifications Section 300-Installation 7-6 DBS 576 (USA), issued 6/2/98 576-13-300 Note: These maximum are based on overall CO line capacities and do not allow for CO lines used for outside lines. VB-44530 Basic Rate Interface (BRI) 12 24 36 48 60 72 VB-44540 Primary Rate Interface (PRI)369121518 VB-44550 T-1 Interface369121518 VB-44560 E&M tie line trunk card 12 24 36 42 60 72 Station Interfaces VB-44110 DTMF signal receiver for 8 SLT lines (MFR/ 8)246888 VB-44610 8-port digital extension...