Page 191
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-17 Figure 6-12. 25-pin to 25-pin D-SUB cable connections Installation 1. Install the API card in an available optional card slot or flexible slot. 2. Connect one end of the RS-232C cable to the RS-232C port (CN4) of the API card and the other end to the PC. Figure 6-13. Connecting API card to PC
Page 192
Chapter 6. Peripheral Equipment Section 300-Installation 6-18 DBS 576 (USA), issued 6/2/98 576-13-300 Voice Recognition Adaptor Guidelines • A VB-44101 voice recognition adaptor can be installed in the VB-44224 key phone so that the phone can be used as a voice recognition phone. • You can call by name or execute other functions by function names. • Locate the Voice Recognition Adaptor within 400 ft. (120m) of the cabinet. The maximum loop circuit resistance to a Voice Recognition Adaptor is 20 Ohms. •...
Page 193
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-19 3. Connect one end of the CW11 and CW13 cables provided with the voice recognition adaptor to connectors CN11 and CN12 in the bottom of the phone. 4. Secure the voice recognition adaptor using the two screws. Figure 6-16. Connecting voice recognition adaptor to key phone 5. Connect the phone to the internal line port on a DEC/8 card (see page 5-31). Figure 6-17. Connecting phone to secondary socket
Page 194
Chapter 6. Peripheral Equipment Section 300-Installation 6-20 DBS 576 (USA), issued 6/2/98 576-13-300 DSS Guidelines • The DSS (VB-44320) is a 72-key console that can be attached to a telephone. It provides direct station selection and busy lamp fields for internal lines. • If more than one DSS is assigned to a telephone, only one of the DSS can be cabled from the same wall jack as the telephone. An additional DSS must be cabled from separate wall jacks. • The DSS comes with a mounting bracket,...
Page 195
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-21 EM24 Guidelines • The EM24 (VB-44310) provides 24 flexible function (FF) keys. It can be attached to any key phone. • The EM24 comes with a mounting bracket, screws, and a two-conductor cable for connecting it to the key phone. • Locate the EM24 within 400 ft. (120m) of the cabinet. The maximum loop circuit resistance to a EM24 is 20 Ohms. Installation 1. Attach the EM24 to the key phone using the...
Page 196
Chapter 6. Peripheral Equipment Section 300-Installation 6-22 DBS 576 (USA), issued 6/2/98 576-13-300 TA P I A d a p t o r Guidelines • The TAPI adaptor acts as an interface between the DBS 576 and the TAPI application on your PC. • To use the TAPI adaptor, you will need a TAPI Service Provide (SP) software. • A 9-pin (female) D-SUB RS-232C cable is provided with your TAPI adaptor. • If your PC is equipped with a 25-pin D-SUB RS232C connector, make the RS- 232C cable shown in Figure 6-4, Connections...
Page 197
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-23 Doorphone Adaptor Guidelines • The Doorphone Adaptor (VB-43701) requires a door opener. In addition, a Doorphone (VB-43705) is normally used with the Doorphone Adaptor. Door openers are not sold by Panasonic, but can be purchased separately from an electronics dealer. • Each Doorphone and door opener use one trunk port. • One or two door openers and two Doorphones can be connected to a Doorphone...
Page 198
Chapter 6. Peripheral Equipment Section 300-Installation 6-24 DBS 576 (USA), issued 6/2/98 576-13-300 Figure 6-21. Doorphone Adaptor cable punch-out plate and wall mounting
Page 199
Section 300-Installation Chapter 6. Peripheral Equipment 576-13-300 DBS 576 (USA), issued 6/2/98 6-25 5. Connect the trunk line(s) to the Doorphone Adaptor, as shown in Figure 6-22. The CO.D connector is used for the Doorphone and opener. The CO.S connector is used for the sensor. 6. Connect the Doorphone, door opener, and sensor to the Doorphone Adaptor. Figure 6-22. Doorphone Adaptor connections
Page 200
Chapter 6. Peripheral Equipment Section 300-Installation 6-26 DBS 576 (USA), issued 6/2/98 576-13-300 Power Failure Transfer Guidelines • Up to four SLTs can be connected to the Power Failure Unit (VB-43703). If a power failure occurs, the SLTs will automatically receive a dial tone from the trunk. The DBS 576 features and restrictions do not apply when SLTs are receiving a dial tone from the trunk line. • If a call is in progress through the Power Failure Unit (PFU) when the power is restored, the...