Section 300-Installation Chapter 5 - Trunks and Extensions 576-13-300 DBS 576 (USA), issued 6/2/98 5-17 E&M Tie Line Trunks Guidelines • E&M Tie Line Trunks are connected to a E&M Tie Line card (VB-44560) installed in a flexible slot of the cabinet. A maximum of 4 trunks can be connected to each E&M Tie Line card. • A -48V Power Supply must be installed in the same cabinet as the E&M/4 card for E&M trunks to operate. • E&M Tie Lines can be directly wired to the network jack (USOC: RJ1CX). • Each...
Page 142
Chapter 5 - Trunks and Extensions Section 300-Installation 5-18 DBS 576 (USA), issued 6/2/98 576-13-300 Figure 5-7. Connecting E&M Tie Line Trunks
Page 143
Section 300-Installation Chapter 5 - Trunks and Extensions 576-13-300 DBS 576 (USA), issued 6/2/98 5-19 T-Point ISDN Interface (TBRI) Guidelines • T-point ISDN is accommodated by the TBRI/4 card which is installed in the flexible slot. Four T-point ISDN lines can be connected to each TBRI/4 card. • T-point ISDN is connected via NT1 (Network Termination Unit (NT1)). • T-point ISDN is connected to the TBRI/4 card using 8-conductor modular connectors. See Figure 5-9 for the pin configuration of the...
Page 144
Chapter 5 - Trunks and Extensions Section 300-Installation 5-20 DBS 576 (USA), issued 6/2/98 576-13-300 Table 5-12. Line Selection Switch (SW1: SELECT) on TBRI/4 Card Installation 1. Align the CN8 connector of the CPC96 card or the CN5 connector of the TSW288 or TSW576 card with the holes of spacers and connect the synchronization package (VB-44460). Figure 5-8. Installation of Sync Package (Example: Installation on TSW288 Card) 2. Insert the CPC96, TSW288, or TSW576 card in the specified slot. 3....
Page 145
Section 300-Installation Chapter 5 - Trunks and Extensions 576-13-300 DBS 576 (USA), issued 6/2/98 5-21 5. Pass the T-point ISDN wires with 8-conductor modular jack through the wiring aperture in the main unit and connect it to the modular connector on the TBRI/4 card. Figure 5-9. Connection of T-Point ISDN Interface (BRI)
Page 146
Chapter 5 - Trunks and Extensions Section 300-Installation 5-22 DBS 576 (USA), issued 6/2/98 576-13-300 T-Point ISDN Primary Rate Interface (PRI) Guidelines • The T-point ISDN primary rate interface carrier line is accommodated on the PRI/ 23 card which is installed in the flexible slot. You can connect one T-point ISDN primary rate interface carrier to each PRI/23 card. • By setting the switch and reprogramming, the PRI/23 card can also be set up as an S-point ISDN primary rate interface (see page...
Page 147
Section 300-Installation Chapter 5 - Trunks and Extensions 576-13-300 DBS 576 (USA), issued 6/2/98 5-23 Table 5-14. Maximum Number of T-Point ISDN Primary Rate Interface Cards Per System Installation 1. Align the CN8 connector of the CPC96 card or the CN5 connector of the TSW288 or TSW576 card with the holes of spacers and connect the SYNC synchronization package. See Figure 5-8 on page 5-20 for how to install the SYNC synchronization package. 2. Insert the CPC96, TSW288, or TSW576 card in the...
Page 148
Chapter 5 - Trunks and Extensions Section 300-Installation 5-24 DBS 576 (USA), issued 6/2/98 576-13-300 Table 5-16. Switch Setting for SW1 on PRI/23 Card 6. Insert the PRI/23 card into the specified flexible slot (see page 4-36) 7. Connect the 8-conductor modular jack via the CSU to the T-point ISDN primary rate carrier line. 8. Pass the T-point ISDN rate carrier wires with 8-conductor modular jack through the wiring aperture of the cabinet and connect it to the modular connector on the PRI/23...
Page 149
Section 300-Installation Chapter 5 - Trunks and Extensions 576-13-300 DBS 576 (USA), issued 6/2/98 5-25 T1 Interface Guidelines • A T1 line is connected to the T1 card which is installed in the flexible slot. You can connect one T1 line to each T1 card. • The T1 line connects to the switched network via a CSU (Channel Service Unit). • Depending on Dip switch SW2-2, the T1 card can be set for 8-channel mode or Other mode. When set for Other mode you can also specify two channel classifications: 1 to...
Page 150
Chapter 5 - Trunks and Extensions Section 300-Installation 5-26 DBS 576 (USA), issued 6/2/98 576-13-300 Installation 1. Align the CN8 connector of the CPC96 card or the CN5 connector of the TSW288 or TSW576 card with the holes of spacers and connect the SYNC synchronization package. See Figure 5-8 on page 5-20 for how to install the SYNC synchronization package. 2. Insert the CPC96, TSW288, or TSW576 card in the specified slot. 3. Set the DIP switch (SW2-1) of the T1 card ON (trunk). 4. Set the...