Home > Panasonic > Air Conditioner > Panasonic Cwxc64hu Operating Instructions Manual

Panasonic Cwxc64hu Operating Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cwxc64hu Operating Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Please read these operating instructions thoroughly
    before using your air conditioner and keep for future reference.
    Il est recommandé de lire attentivement ce manuel avant
    dutiliser lappareil. Conservez ce manuel.
    For U.S customers :
    For assistance, please call : 1-800-211-PANA(7262) or 
    Register your product at : http://www.panasonic.com/register
    For customers in Canada :
    For assistance, please call : 905-624-5505
    Au Canada : Pour de laide, composez le 905-624-5505.
    INSTALLATION AND OPERATING INSTRUCTIONS
    MANUEL DINSTALLATION ET DUTILISATION
    Room Air Conditioner
    Climatiseur de fenêtre
    Models, Modèles:CW-XC64HU, CW-XC64HK, CW-C84GU
    CW-XC84GU, CW-XC84HU, CW-XC84HK
    CW382820391B
    R 
    						
    							2
    Safety Precautions
    About the Controls on the Air Conditioner
    Features and Installation
    Before you call for service...
    FOR YOUR RECORDS
    Staple your receipt to this page in case you need it later.
    Write down the model and serial numbers here:
    Model #
    Serial #
    You can find them on a label on the side of each unit.
    Dealers Name
    Date Purchased
    Inside you will find many helpful hints on how to use and
    maintain your air conditioner properly. Just a little preventive
    care on your part can save you a great deal of time and
    money over the life of your air conditioner.
    Youll find many answers to common problems in the chart
    of troubleshooting tips. If you review our chart of
    Troubleshooting Tipsfirst, you may not need to call for
    service at all.
    READ THIS MANUAL
    CAUTION
    • Contact the authorized Service technician for repair or
    maintenance of this unit.
    • The air conditioner is not intended for use by young
    children or infirm persons without supervision.
    • Young children should be supervised to ensure that they
    do not play with the air conditioner.
    Safety Precautions
    Safety Precautions .............3
    About the Controls on
    the Air Conditioner
    Controls ..............................5
    Remote Controller ..............7
    Ventilation ..........................8
    Air Direction........................8
    How to Secure Drain Pipe....8
    Care and Maintenance 
    Air Filter Cleaning...............9
    Features
    Features ...........................10
    Installation
    How to Install the Unit ......11
    Window Requirements .....11
    Installation Kit Contents ...12
    Suggested Tool
    Requirements ...................12
    Cabinet Installation...........13
    Electrical Data ..................15
    Electrical Safety ...............16
    Before you call for
    service...
    Normal Operation .............17
    Abnormal Operation .........17 
    						
    							WARNING
    3
    Safety PrecautionsSafety Precautions 
    To prevent injury to the user or other people and property damage, the following instructions must be
    followed.
    Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified
    by the following indications.
    WARNING: This symbol indicates the possibility of death or serious injury.
    CAUTION:This symbol indicates the possibility of injury or damage to
    property only.
    Meanings of symbols used in this manual are as shown below.
    Be sure not to do this.
    Be sure to follow the instructions.
    Plug in the power plug
    properly.
    • Otherwise, it will cause electric
    shock or fire due to heat
    generation.
    Do not operate or stop the
    unit by inserting or pulling
    out the power plug.
    • It will cause electric shock or fire
    due to heat generation.
    Do not damage or use an
    unspecified power cord.
    • It will cause electric shock or fire.
    • 
    If the power cord is damaged, it must
    be replaced by the manufacturer or
    an authorized service center or a
    similarly qualified person in order to
    avoid a hazard.
    Do not modify power cord
    length or share the outlet
    with other appliances.
    • It will cause electric shock or fire
    due to heat generation.
    Do not operate with wet
    hands or in a damp
    environment.
    • It will cause electric shock.
    Do not direct air flow at room
    occupants.
    • This could lead to health
    problems. 
    						
    							4
    Safety Precautions
    When the air filter is to be
    removed, do not touch the
    metal parts of the unit.
    • It may cause an injury.
    Do not clean the air
    conditioner with water.
    • Water may enter the unit and
    degrade the insulation. It may
    cause an electric shock.
    Ventilate well when used
    together with a stove, etc.
    • An oxygen shortage may occur.
    When the unit is to be
    cleaned, switch off, and turn
    off the breaker.
    • Since the fan rotates at high
    speed during operation, it may
    cause an injury.
    Do not put a pet or house
    plant where it will be exposed
    to direct air flow.
    • This could injure the pets or
    plants.
    Do not use for special
    purposes.
    • Do not use this air conditioner to
    preserve precision devices, food,
    pets, plants, and art objects. 
    It may cause deterioration of
    quality, etc.
    Do not operate switches 
    with wet hands
    .
    • It may cause an electric shock.
    Do not apply an insecticide 
    or flammable spray.
    • It may cause a fire or deformation
    of the cabinet.
    Do not put a heater, etc.
    where it is exposed to direct
    air flow.
    •It may cause imperfect
    combustion. 
    						
    							5
    About the Controls on the Air Conditioner
    About the Controls on the Air Conditioner
    The controls will look like one of the following.
    Controls
    When the air conditioner has performed its cooling operation and is turned off or set to the fan
    position, wait at least 3 minutes before resetting to the cooling operation again.
    Off- Turns air conditioner off.
    Med Fan- Med speed fan operation without cooling.
    Low Fan- Low speed fan operation without cooling.
    High Cool- Cooling with high speed fan operation.
    Med Cool- Cooling with med speed fan operation.
    Low Cool- Cooling with low speed fan operation.
    This automatically controls the temperature of the indoor air.
    Turn the knob so that arrow points to the higher number for greater cooling.
    Point the arrow to the lower number for more moderate cooling.
    (i.e. the higher the number, the greater the cooling)
    • FOR NORMAL COOLING
    1. Turn the operation switch to the High Cool or the Low Cool setting.
    2. Set the Thermostat control to the desired temperature mark 5(the mid-point is a good starting position). 
    If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer
    setting, as appropriate.
    • FOR MAXIMUM COOLING
    1. Turn the Operation Knob to the High Cool setting.
    2. Set the Thermostat control to the largest (9) temperature mark.
    • FOR QUIETER OPERATION
    1. Turn the Operation Knob to the Low Cool setting.
    2. Set the Thermostat control as needed.
    CAUTION Model : CW-C84GU 
    						
    							Model: CW-XC84HU
    Models: CW-XC64HK, CW-XC84HK
    Model: CW-XC80HU
    TIMERFA N ECONOMYCOOL
    DRY
    TIMER TIMERMODE
    MODEOFF/ON
    FA N
    SPEED
    AIR
    SWINGAIR
    SWING
    F
    hr
    FA NCOOL
    DRY
    hrF
    OPERATION TEMP TEMP
    TIMERMODEOFF/ON
    FA N
    SPEEDFA N
    SPEED
    4
    1
    7
    8
    325
    4
    1
    3625
    8
    1
    8
    4
    325
    OPERATION
    TEMP
    Models: CW-XC64HU, CW-XC84GU
    TIMERAIR
    SWINGAIR
    SWINGFA N ECONOMYCOOL
    DRY
    TIMER TIMERMODE
    MODEOFF/ON
    F
    hr
    FA N
    SPEED4
    1
    8
    325
    OPERATION
    TEMP
    6
    About the Controls on the Air Conditioner
    Controls
    OPERATION
    • To turn the air conditioner ON, push the
    OFF/ON button.
    To turn the air conditioner OFF, push the
    button again.
    • This button takes priority over any other
    buttons.
    • When you first turn it on, the air conditioner
    is on the High cool mode and the temp. at
    72°F (22°C)
    MODE
    • Evey time you push this button,it will toggle
    between COOL, FAN, DRY.
    (Models:CW-XC64HK,CW-XC84HK)
    • Every time you push this button, it will
    toggle between COOL,ECONOMY, FAN
    and DRY.
    (Models:CW-XC64HU, CW-XC84HU,
    CW-XC84GU)
    ON/OFF TIMER
    • Every time you push the TIMER button,
    timer is set as follows. (1Hour 2Hours 
    3Hours 4Hours 5Hours 6Hours 
    7Hours 8Hours 9Hours 10Hours 
    11Hours 12Hours O)
    • The Setting Temperature will be raised by
    2°F(1˚C) 30 min. later and by 2°F(1˚C) after
    another 30 min.
    FAN SPEED
    • Every time you push this button it is set as
    follows. {High(F3) Low(F1) Med(F2) 
    High(F3)...}.
    TEMPERATURE SETTING
    • This button can automatically control the
    temperature of the room. The temperature can
    be set within a range of 60°F to 86°F by 1°F
    (16˚C to 30˚C by 1˚C) Select the lower number
    for lower temperature of the room.
    ECONOMY
    (Models: CW-XC64HK, CW-XC84HK)
    • If you push the button, the fan stops when the
    compressor stops cooling.
    • Approximately every 3 minutes the fan will turn
    on and check the room air to determine if
    cooling is needed.
    AIR SWING
    • This button can automatically control the air flow
    direction.
    REMOTE CONTROL SIGNAL RECEIVER 
    						
    							OPERATION
    TEMP
    TIMERAIR
    SWING
    MODE
    ECONOMYFAN SPEED1
    3
    24
    6
    5
    7
    OPERATION
    TEMP
    TIMER
    MODE
    ECONOMYFAN SPEED1
    3
    24
    6
    5
    Model: CW-XC84HUModels: CW-XC64HU, CW-XC64HK
      CW-XC84GU, CW-XC84HK
    7
    About the Controls on the Air Conditioner
    Remote controller
    OPERATION
    • To turn the air conditioner ON, push the button. 
    To turn the air conditioner OFF, push the button
    again.
    • This button takes priority over any other buttons.
    • When you first turn it on, the air conditioner is on
    the High cool mode and the temp. at 72°F (22˚C).
    MODE
    • Every time you push this button, it will toggle
    between COOL, FAN and DRY. 
    (Models:CW-XC64HK, CW-XC84HK)
    • Every time you push this button,it will toggle
    between COOL, ECONOMY, FAN and DRY.
    (Models: CW-XC64HU, CW-XC84HU,
    CW-XC84GU)
    ON/OFF TIMER
    - STOPPING OPERATION
    • Every time you push this button,  when the air
    conditioner is operating, timer is set as follows.
    (1Hour 2Hours 3Hours 4Hours 5Hours
    6Hours 7Hours 8Hours 9Hours 
    10Hours 11Hours 12Hours O)
    • The Setting Temperature will be raised by 
    2°F (1°C) 30 min. later and by 2°F (1°C) after
    another 30 min.
    - STARTING OPERATION
    • Every time you push this button, when the air
    conditioner is not operating, timer is set as follows.
    (1Hour 2Hours 3Hours 4Hours 5Hours
    6Hours 7Hours 8Hours 9Hours 
    10Hours 11Hours 12Hours O)
    FAN SPEED
    • Every time you push this button it is set as follows.
    {High(F3) Low(F1) Med(F2) High(F3)...}.
    TEMPERATURE SETTING
    • This button can automatically control the
    temperature of the room. 
    The temperature can be set within a range of 60°F
    to 86°F by 2°F.(16˚C to 30˚C by 1˚C) Select the
    lower number for lower temperature of the room.
    ECONOMY
    • If the switch is set to On, the fan stops when the
    compressor stops cooling. Approximately every 3
    minutes the fan will turn on and check the room air
    to determine if cooling is needed.
    AIR SWING
    • This button can automatically control the air flow
    direction.
    DRY
    • When this unit is in dry mode, the fan rotates in
    low speed. The fan stops when the compressor
    stops cooling.
    Approximately every 3 minutes the fan will turn on
    and the unit checks the room air temperature to
    set itself.
    Precaution:The Remote Controller will not function properly if strong light strikes the sensor window of the
    air conditioner or if there are obstacles between the Remote Controller and the air conditioner. 
    						
    							VENT CLOSE
    OPEN
    Par tA
    Par tB
    Drain pipe
    Drain cap
    Fig. 4 Fig. 3
    Fig. 2
    DRAIN
    PA NDRAIN HOSE
    Inside diameter 17mm (5/8)
    Fig. 1
    CABINET
    SCREW
    Controlled
    manuallyControlled
    manuallyControlled by Remote
    Controller (Model: CW-XC84HU)
    O
    F
    F
    /
    O
    NO
    P
    ER
    A
    T
    I
    O
    NTEMP/TIMERC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    D
    E
    F
    A
    N 
    S
    P
    E
    E
    DSETT
    I
    MERS
    E
    T
    /
    C
    A
    N
    C
    E
    LA
    I
    R
     
    S
    W
    I
    N
    GECONOMYh
    r FW
    i
    re
    l
    e
    s
    sR
    e
    m
    o
    t
    e
     C
    o
    n
    t
    ro
    l
    Remove therubber plug
    O
    F
    F/
    O
    NO
    P
    E
    R
    A
    T
    I
    O
    NT
    E
    P
    /T
    IC
    O
    O
    L
    F
    A
    N
    H
    I
    G
    H
    M
    E
    D
    L
    O
    WM
    O
    E
    F
    A
    N
     
    S
    P
    E
    E
    DS
    ETTIMERS
    E
    T
    /
    C
    N
    EA
    I
    R
     ECONOMYFW
    ir
    e
    l
    e
    s
    sR
    em
    o
    te
     
    C
    o
    n
    t
    r
    o
    l
    8
    About the Controls on the Air Conditioner
    Additional controls and important information.
    Ventilation
    The ventilation lever must be in the CLOSE position in order to maintain the best
    cooling conditions. When fresh air is necessary in the room, set the ventilation
    lever to the OPEN position. 
    The damper is opened and room air is drawn out.
    NOTE:Before using the ventilation feature, and prior to installing the front grille,
    pull down part 
    until level with part .
    Air Direction
    The vertical air direction is adjusted by
    rotating the horizontal louver forward or
    backward manually.The horizontal air direction is adjusted by rotating
    the vertical louver right or left manually or by
    Remote Controller. The direction of air can be controlled wherever you want to cool by adjusting the horizontal
    louver and the vertical louver.
    •VERTICAL AIR-DIRECTION CONTROL•HORIZONTAL AIR-DIRECTION CONTROL
    How to Secure the Drain Pipe
    In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the
    DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. Press the drain pipe into the
    hole by pushing down and away from the fins to avoid injury.(See Fig.1)
    Optional(CW3H02502C)
    1. Remove the rubber plug and slide the chassis out
    from the cabinet.(See Fig.2)
    2. Install the drain pan over the corner of the cabinet
    where you removed the plug with 4 (or 2)
    screws.(See Fig.3)
    3. Connect the drain hose to the outlet located at the
    bottom of the drain pan. You can purchase the drain
    hose or tubing locally to satisfy your particular
    needs. (Drain hose is not supplied).(See Fig.3)
    4. Select the most appropriate connection from among
    the figures to the right (by considering the hole of the
    unit) to fit drain pan to your own unit.(See Fig.3)
    5. Slide the chassis back into the cabinet. Reinstall the
    cabinet screws. Secure the cabinet to chassis by
    using screws. (See Fig.4) 
    						
    							9
    About the Controls on the Air Conditioner
    Air Filter Cleaning
    The air filter behind the front grille should be checked and cleaned at least once every 2
    weeks or more often if necessary.
    TO REMOVE: 
    1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by
    pulling out the top of the inlet grille.
    2. Using the tab, pull up slightly on the filter to release it and pull it down or up.
    3. Clean the filter with warm, soapy water under 40°C (104°F).
    4. Rinse and gently shake the water from the filter and let it dry before replacing it.
    CAUTION:DO NOT operate the air conditioner without a filter because dirt and lint will
    clog it and reduce performance.
    How to Insert Batteries
    Care and Maintenance
    TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.
    1.Remove the cover from the back of the
    remote controller.
    2.Insert two AAA dry cell batteries.
    • Be sure that the (+) and (-)  directions
    are correct.
    • Be sure that both batteries are new.
    3.Re-attach the cover.• Do not use rechargeable
    batteries. Such batteries 
    differ from standard dry
    cells in shape,
    dimensions, and
    performance.
    • Remove the batteries
    from the remote
    controller if the air
    conditioner is not going
    to be used for an
    extended length of time. 
    						
    							10
    Features and Installation
    Learning parts name prior to installation will help you understand the installation procedure.
    Features
    Features
    CABINET
    FRONT GRILLE
    AIR FILTER
    AIR INTAKE
    (INLET GRILLE) AIR DISCHARGE HORIZONTAL AIR DEFLECTOR
    (VERTICAL LOUVER) VERTICAL AIR DEFLECTOR
    (HORIZONTAL LOUVER)
    EVAPORATOR
    POWER CORD BASE PAN CONDENSER COMPRESSOR BRACE
    BRACE
    CONTROL BOARD
    EVAPORATOR
    POWER CORD BASE PAN CONDENSER COMPRESSOR BRACE
    CONTROL BOARD
    REMOTE CONTROLLERVERTICAL LOUVER
    Models: CW-XC84HU
    Models: CW-XC64HK
    CW-XC84HK
    CW-XC64HU
    CW-XC84GU
    REMOTE CONTROLLER
    FAN
    ECONOMYCOOL
    DRYTIMERTIMER
    TIMERMODE
    MODEO
    F
    F
    /
    O
    N
    F
    h
    rFAN
    SPEED
    AIR
    SWING AIR
    SWING
    POWER CORD BASE PAN CONDENSER COMPRESSOR
    EVAPORATOR
    CONTROL BOARD
    Model: CW-C84GU 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cwxc64hu Operating Instructions Manual