Home > Panasonic > Air Conditioner > Panasonic Cu 3ks19nbucu 4ksxxnbu Technical Service Manual

Panasonic Cu 3ks19nbucu 4ksxxnbu Technical Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Panasonic Cu 3ks19nbucu 4ksxxnbu Technical Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Outdoor UnitCU-4KS24NBU
    Indoor UnitCS-MKS7NKU + CS-MKS9NKU × 2
    < 230V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKE7NKU 1units / CS-MKE9NKU 2units        Outdoor Unit : CU-4KS24NBU  1unit
      The combination indoor unit is AHRI 210/240.
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control10.7
    2,420 24,200
    7.10( 9,800 to 25,400 )
    ( 2.90 to 7.50 )
    Shipping VolumeCooling
    20,300
    3,900
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    138.9
    147.7(63.0)
    (67.0)
    13.41  (0.38) (740 × 900 × 320)Outdoor Unit
    29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 3 + 1/2 (12.7) × 1 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    82 (25) R410A / 6.17 (2,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    50 BTU/h
    Performance
    % Power Factor98
    A 13.0 Type
    BTU/hkW Total Capacity
    BTU/h
    SEER BTU/Wh 18.0
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    230V Single-Phase 60Hz Voltage Rating
    1,707 (2,900) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 10.0
    Fuse or Circuit Breaker Capacity A 20
    Duct Less Type Rated
    34-3/16 × 41-11/32 × 16-21/32
    (868 × 1,050 × 423)
    11 
    						
    							Outdoor UnitCU-4KS24NBU
    Indoor UnitCS-MKS9NKU ×
    3
    < 230V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKS9NKU   3units        Outdoor Unit : CU-4KS24NBU  1unit
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control11.3
    2,560 25,400
    7.50( 9,800 to 25,400 )
    ( 2.90 to 7.50 )
    Shipping VolumeCooling
    21,400
    4,000
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    138.9
    147.7(63.0)
    (67.0)
    13.41  (0.38) (740 × 900 × 320)Outdoor Unit
    29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 3 + 1/2 (12.7) × 1 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    82 (25) R410A / 6.17 (2,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    50 BTU/h
    Performance
    % Power Factor98
    A 13.0 Type
    BTU/hkW Total Capacity
    BTU/h
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    230V Single-Phase 60Hz Voltage Rating
    1,707 (2,900) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 9.9
    Fuse or Circuit Breaker Capacity A 20
    34-3/16 × 41-11/32 × 16-21/32
    (868 × 1,050 × 423)
    12 
    						
    							Outdoor UnitCU-4KS24NBU
    Indoor UnitCS-MKS9NKU ×
    3
    < 208V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKS9NKU   3units        Outdoor Unit : CU-4KS24NBU  1unit
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control12.1
    2,460 24,400
    7.20( 9,800 to 24,400 )
    ( 2.90 to 7.20 )
    Shipping VolumeCooling
    20,600
    3,800
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    138.9
    147.7
    13.41  (0.38)(63.0)
    (67.0) (740 × 900 × 320)Outdoor Unit
    29-1/8 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 3 + 1/2 (12.7) × 1 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    82 (25) R410A / 6.17 (2,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    50 BTU/h
    Performance
    % Power Factor98
    A 13.0 Type
    BTU/hkW Total Capacity
    BTU/h
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    208V Single-Phase 60Hz Voltage Rating
    1,707 (2,900) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 9.9
    Fuse or Circuit Breaker Capacity A 20
    34-3/16 × 41-11/32 × 16-21/32
    (868 × 1,050 × 423)
    13 
    						
    							Outdoor UnitCU-4KS31NBU
    Indoor UnitCS-MKS7NKU × 3 + CS-MKS9NKU
    < 230V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKE7NKU 3units / CS-MKE9NKU 1units        Outdoor Unit : CU-4KS31NBU  1unit
      The combination indoor unit is AHRI 210/240.
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control11.4
    2,600 29,000
    8.50( 9,800 to 29,000 )
    ( 2.90 to 8.50 )
    Shipping VolumeCooling
    24,400
    4,600
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    174.2
    183.0(79.0)
    (83.0) 40-1/8 × 41-11/32 × 16-21/32
    (1,019 × 1,050 × 423)(890 × 900 × 320)Outdoor Unit
    35-1/32 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 2 + 1/2 (12.7) × 2 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    100 (30.5) R410A / 8.38 (3,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    53 BTU/h
    Performance
    % Power Factor99
    A 17.0 Type
    BTU/hkW Total Capacity
    BTU/h
    SEER BTU/Wh 17.6
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    230V Single-Phase 60Hz Voltage Rating
    1,942 (3,300) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 11.2
    Fuse or Circuit Breaker Capacity A 20
    15.88  (0.45)
    Duct Less Type Rated
    14 
    						
    							Outdoor UnitCU-4KS31NBU
    Indoor UnitCS-MKS9NKU ×
    4
    < 230V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKS9NKU   4units        Outdoor Unit : CU-4KS31NBU  1unit
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control12.3
    2,800 30,600
    9.00( 9,800 to 30,600 )
    ( 2.90 to 9.00 )
    Shipping VolumeCooling
    25,800
    4,800
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    174.2
    183.0(79.0)
    (83.0) (890 × 900 × 320)Outdoor Unit
    35-1/32 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 2 + 1/2 (12.7) × 2 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    100 (30.5) R410A / 8.38 (3,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    53 BTU/h
    Performance
    % Power Factor99
    A 17.0 Type
    BTU/hkW Total Capacity
    BTU/h
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    230V Single-Phase 60Hz Voltage Rating
    1,942 (3,300) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 10.9
    Fuse or Circuit Breaker Capacity A 20
    15.88  (0.45) 40-1/8 × 41-11/32 × 16-21/32
    (1,019 × 1,050 × 423)
    15 
    						
    							Outdoor UnitCU-4KS31NBU
    Indoor UnitCS-MKS9NKU ×
    4
    < 208V >
    Remarks:
    1.  The values shown in performance section and electrical rating section above are based on the following unit combination.
      For other combination unit, please refer to the "Unit Combination Tables" in this manual.
                         Indoor Unit : CS-MKS9NKU   4units        Outdoor Unit : CU-4KS31NBU  1unit
    2.  Rating conditions are:  Cooling :  Indoor air temp.  80 °F DB / 67 °F WB
          Outdoor air temp.  95 °F DB / 75 °F WBDATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor
    Refrigerant / Amount charged at shipment Ibs (g)
    Refrigerant Control12.7
    2,560 28,600
    8.40( 9,800 to 28,600 )
    ( 2.90 to 8.40 )
    Shipping VolumeCooling
    24,200
    4,400
    Net
    Shipping Package Dimensions
    WeightHeight × Width × Depth
    Height × Width × Depth
    Ibs (kg)
    Ibs (kg)
    cu.ft (m
    3) (mm)
    inch
    (mm)4-Room Multi Outdoor Unit
    Outdoor Unit
    inch187 to 253
     Dimensions & Weight
    Refrigerant Tubing Connections
    Unit Dimensions
    Electrical Rating
    Sensible Capacity
    Latent Capacity
    W Power InputV
    A Available Voltage Range
    Running Amperes
    Operation Sound (High) Cool
    Narrow tube
    Wide tube Refrigerant inch (mm)
    Tube Diameter inch (mm)
    174.2
    183.0(79.0)
    (83.0) (890 × 900 × 320)Outdoor Unit
    35-1/32 × 35-7/16 × 12-19/321/4 (6.35) × 4
    3/8 (9.52) × 2 + 1/2 (12.7) × 2 ft (m)dB-A
    Max. allowable tubing length per unitFlare Type
    100 (30.5) R410A / 8.38 (3,800)
    Electric Expansion Valve DC Twin Rotary (Inverter) Fan Speeds Auto (Hi, Me, Lo) ControlMicroprocessor
    Features
    Compressor Locked Rotor Amperes
    53 BTU/h
    Performance
    % Power Factor99
    A 17.0 Type
    BTU/hkW Total Capacity
    BTU/h
    4 Number of Connectable Indoor Units
    4 Number of Operatable Indoor Units
    208V Single-Phase 60Hz Voltage Rating
    1,942 (3,300) Air Circulation  (High) ft3/min (m3/h)
    EER BTU/h/W 11.2
    Fuse or Circuit Breaker Capacity A 20
    15.88  (0.45) 40-1/8 × 41-11/32 × 16-21/32
    (1,019 × 1,050 × 423)
    16 
    						
    							Outdoor UnitCU-3KS19NBU
    2-2-1.  Outdoor Unit
    Control PCB
    Control Circuit Fuse  ControlsPart No.
    Microprocessor
    250V 25A CB-CU-3KS19NBU
    DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc)
     
    -
     
    Micro F
    VAC
     External FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900)
    -
    - Internal Controller
    Yes
    Yes
    Aluminum Plate Fin / Copper Tube
    2
    18.1
     Face Area
    ft
    2 (m2)6.40 (0.595)  Coil
    Rows
    Fins per inch Heat Exchanger Coil   
    SIC-71FW-D490-1 ... 1  
    Compressor Oil ...  Amount
    8
    90 750
     OhmDC Motor      Type
    Compressor Model / Nominal Output Compressor
    Coil Resistance (Ambient Temp. 68 °F (20 °C))
    OhmDC Twin Rotary (Hermetic)
    5KD240XAB21 / 1,700W
    U - V :
    V - W :
    W - U :0.720
    0.708
    0.726
    CT (Peak current cut-off control)
    Compressor Discharge Temp. Control
    Operation cut-off control in abnormal ambient Temp.
    Safety Device
    Micro F
    VAC Run Capacitor
    Crankcase HeaterYes
    Yes
    Yes
    Overload Relay
    CS-7L-2515 Model
    Operation Temp.
    Open : 239 °F (115 °C), Close : 212 °F (100 °C)
    -
    -
    230V 30W
    1 ... D18-1/8 (D460) Fan
    Propeller
    Q'ty ... Dia. inch (mm) Type
    Type
    Over-Current Protection
    Over-Heat Protection (Ambient Temp. 68 °F (20 °C))  Fan Motor
    Nominal Output
    Coil Resistance
    Safety DeviceRough Measure RPM (Cool)
    Run Capacitor Type
    Model ... Q'ty
    No. of Poles
    W
    2-2.  Major Component Specifications
    17 
    						
    							Outdoor UnitCU-4KS24NBU
    Control PCB
    Control Circuit Fuse  ControlsPart No.
    Microprocessor
    250V 25A CB-CU-4KS24NBU
    DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc)
     
    -
     
    Micro F
    VAC
     External FinishAcrylic baked-on enamel finishFV50S ... 1.91 (900)
    -
    - Internal Controller
    Yes
    Yes
    Aluminum Plate Fin / Copper Tube
    2
    18.1
     Face Area
    ft
    2 (m2)6.40 (0.595)  Coil
    Rows
    Fins per inch Heat Exchanger Coil   
    SIC-71FW-D490-1 ... 1  
    Compressor Oil ...  Amount
    8
    90 750
     OhmDC Motor      Type
    Compressor Model / Nominal Output Compressor
    Coil Resistance (Ambient Temp. 68 °F (20 °C))
    OhmDC Twin Rotary (Hermetic)
    5KD240XAB21 / 1,700W
    U - V :
    V - W :
    W - U :0.720
    0.708
    0.726
    CT (Peak current cut-off control)
    Compressor Discharge Temp. Control
    Operation cut-off control in abnormal ambient Temp.
    Safety Device
    Micro F
    VAC Run Capacitor
    Crankcase HeaterYes
    Yes
    Yes
    Overload Relay
    CS-7L-2515 Model
    Operation Temp.
    Open : 239 °F (115 °C), Close : 212 °F (100 °C)
    -
    -
    230V 30W
    1 ... D18-1/8 (D460) Fan
    Propeller
    Q'ty ... Dia. inch (mm) Type
    Type
    Over-Current Protection
    Over-Heat Protection (Ambient Temp. 68 °F (20 °C))  Fan Motor
    Nominal Output
    Coil Resistance
    Safety DeviceRough Measure RPM (Cool)
    Run Capacitor Type
    Model ... Q'ty
    No. of Poles
    W
    18 
    						
    							Outdoor UnitCU-4KS31NBU
    Control PCB
    Control Circuit Fuse  ControlsPart No.
    Microprocessor
    250V 25A CB-CU-4KS31NBU
    DATA SUBJECT TO CHANGE WITHOUT NOTICE. Pints (cc)
     
    -
     
    Micro F
    VAC
     External FinishAcrylic baked-on enamel finishFV50S ... 2.55 (1,200)
    -
    - Internal Controller
    Yes
    Yes
    Aluminum Plate Fin / Copper Tube
    2
    18.1
     Face Area
    ft
    2 (m2)7.75 (0.72)  Coil
    Rows
    Fins per inch Heat Exchanger Coil   
    SIC-71FW-D490-1 ... 1  
    Compressor Oil ...  Amount
    8
    90 800
     OhmDC Motor      Type
    Compressor Model / Nominal Output Compressor
    Coil Resistance (Ambient Temp. 68 °F (20 °C))
    OhmDC Twin Rotary (Hermetic)
    5JD420XAB22 / 3,000W
    U - V :
    V - W :
    W - U :0.435
    0.441
    0.452
    CT (Peak current cut-off control)
    Compressor Discharge Temp. Control
    Operation cut-off control in abnormal ambient Temp.
    Safety Device
    Micro F
    VAC Run Capacitor
    Crankcase HeaterYes
    Yes
    Yes
    Overload Relay
    CS-7L-2515 Model
    Operation Temp.
    Open : 239 °F (115 °C), Close : 212 °F (100 °C)
    -
    -
    230V 30W
    1 ... D18-1/8 (D460) Fan
    Propeller
    Q'ty ... Dia. inch (mm) Type
    Type
    Over-Current Protection
    Over-Heat Protection (Ambient Temp. 68 °F (20 °C))  Fan Motor
    Nominal Output
    Coil Resistance
    Safety DeviceRough Measure RPM (Cool)
    Run Capacitor Type
    Model ... Q'ty
    No. of Poles
    W
    19 
    						
    							Temperature  F (  C)
    40
    35
    30
    25
    20
    15
    10
    5
    0
    (
    -20)(-15)(-10) (-5) (0) (5) (10) (15) (20)-4 5 14 23 32 41 50 59 68
    Resistance (k ohm)
    0
    32 50 68 86 104 122 140 158 176 194 40 60 80 100 120 140 160 180 200
    20
    Resistance (k ohm)
    (0) (10) (20) (30) (40) (50) (60) (70) (80) (90)
    Temperature  F (  C)
    2-3.  Other Component Specifications
    CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU Sensor Name
    Compressor temp sensor TKS293BModel No.
    of sensor
    11Quantity of Sensor
    1
    Outdoor air temp sensor
    Outdoor heat exchanger sensor
    AW / AN sensor
    BW / BN sensor
    CW / CN sensor
    DW / DN sensorTKS295B
    TKS292B
    TKS292B
    TKS292B
    TKS292B
    TKS292B Model No.
    of sensor Sensor Name
    1
    1
    1 / 1
    1 / 1
    1 / 1
    0Quantity of Sensor
    1
    1
    1 / 1
    1 / 1
    1 / 1
    1 / 1 1
    1
    1 / 1
    1 / 1
    1 / 1
    1 / 1 CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU
    20 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cu 3ks19nbucu 4ksxxnbu Technical Service Manual