IMPORTANT These air conditioners employ new refrigerant R410A. Pay special attention when servicing the unit. Wall mounted type CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU< Applicable Indoor Units > TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Product Code No. 1 852 361 24 1 852 361 25 1 852 361 26 REFERENCE NO. SM700877 Capacity at 230V 19,700 BTU/h 25,400 BTU/h 30,600 BTU/hOutdoor Model No. CU-3KS19NBU CU-4KS24NBU...
Page 2
• Before doing repair work, please read the " SAFETY PRECAUTIONS" carefully and fully understand them. • The precautionary items here are divided into " Warning" and " Caution" items. Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly, are included in the " Warning" table. However, even precautionary items identified as " Caution" also have the potential for serious...
Page 3
Warning If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite. If refrigerant gas leaks during the work, ventilate the room. If refrigerant gas catches fire, harmful gas may be generated. Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle. If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle, which may cause a unit breakdown." When the welded section of the...
Page 4
Table of Contents 2 4 6 7 8 17 20 21 24 27 50 56 62 65 69 71 72 73 74 78 .............................................................................................................. ...................................................................................................................... ........................................................................................................
Page 5
79 80 81 81 82 84 85 85 A-1 ......................................................................... ................................................................................................... ................................................................................................ ............................................................................................ .......................................................................................
Page 6
APPLICABLE INDOOR UNITS CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU Multi-Outdoor UnitIndoor Unit3-Room 4-Room 4-Room CS-MKS7NKU YES YES YESYES YES YESYES YES YESYES YES YESNO YES YES CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU Wall Mounted Type CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU Multi-Outdoor UnitIndoor Unit3-Room 4-Room 4-Room CS-MKS9NB4U& CZ-18BT1U YES YES YESYES YES YESYES YES YESCS-MKS12NB4U& CZ-18BT1UCS-KS18NB4UW& CZ-18BT1U Semi-Concealed Type 6
Page 7
95 °F DB / 71 °F WB 67 °F DB / 57 °F WB 1. OPERATING RANGE Maximum Minimum115 °F DB 14 °F DB Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling 7
Page 8
2. SPECIFICATIONS 2-1. Unit Specifications Outdoor UnitCU-3KS19NBU Indoor UnitCS-MKS9NKU × 2 < 230V > DATA SUBJECT TO CHANGE WITHOUT NOTICE. Compressor Refrigerant / Amount charged at shipment Ibs (g) Refrigerant Control6.3 1,420 17,000 5.00( 6,800 to 18,800 ) ( 1.90 to 5.50 ) Shipping VolumeCooling 14,300 2,700 Net Shipping Package Dimensions WeightHeight × Width × Depth Height × Width × Depth Ibs (kg) Ibs (kg) cu.ft (m 3) (mm) inch (mm)3-Room Multi Outdoor Unit Outdoor Unit inch187 to 253 Dimensions...
Page 9
Outdoor UnitCU-3KS19NBU Indoor UnitCS-MKS9NKU × 3 Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKS9NKU 3units Outdoor Unit : CU-3KS19NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Outdoor air temp. 95 °F DB / 75 °F WB < 230V...
Page 10
Outdoor UnitCU-3KS19NBU Indoor UnitCS-MKS9NKU × 3 < 208V > Remarks: 1. The values shown in performance section and electrical rating section above are based on the following unit combination. For other combination unit, please refer to the "Unit Combination Tables" in this manual. Indoor Unit : CS-MKS9NKU 3units Outdoor Unit : CU-3KS19NBU 1unit 2. Rating conditions are: Cooling : Indoor air temp. 80 °F DB / 67 °F WB Outdoor air temp. 95 °F DB / 75 °F...