Page 51
Outdoor Unit : CU-3KS19NBU Indoor Unit : CS-MKS12NB4U × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB : Outdoor Ambient Temp. 95 °F (35 °C) DB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation...
Page 52
Outdoor Unit : CU-4KS24NBU Indoor Unit : CS-MKS9NKU × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB : Outdoor Ambient Temp. 95 °F (35 °C) DB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation...
Page 53
Outdoor Unit : CU-4KS24NBU Indoor Unit : CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U Power Supply : 230V Single Phase 60Hz < Cooling Capacity > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB : Outdoor Ambient Temp. 95 °F (35 °C) DB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection...
Page 54
Outdoor Unit : CU-4KS31NBU Indoor Unit : CS-MKS9NKU × 4 Power Supply : 230V Single Phase 60Hz RATING CAPACITY: 30,600 BTU/h AIR FLOW RATE: 1,036 CFM INDOOROUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 65 75 85 95 105 115 (18.3) (23.9) (29.4) (35.0) (40.6) (46.1) TC 30,850 29,770 28,590 27,980 22,750 16,560 72 (22.2) SHC 24,260 23,660 23,260 22,860 20,440 16,560 59 76 (24.4) SHC 27,890 27,280 26,680 26,480 22,750 16,560 (15.0) 80 (26.7) SHC 30,850 29,770 28,590 27,980 22,750...
Page 55
Outdoor Unit : CU-4KS31NBU Indoor Unit : CS-MKS9NB4U × 4 Power Supply : 230V Single Phase 60Hz < Cooling Capacity > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 80 °F (26.7 °C) DB / 67 °F (19.4 °C) WB : Outdoor Ambient Temp. 95 °F (35 °C) DB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation...
Page 56
Outdoor Unit : CU-3KS19NBU Indoor Unit : CS-MKS9NKU × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > 5-3. Cooling Capacity (Low Ambient) TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE RATING CAPACITY: 18,800 BTU/h AIR FLOW RATE: 777 CFM INDOOROUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 19,220 19,090 19,080 19,160 19,010 72 (22.2) SHC 16,390 19,090 16,240 16,390...
Page 57
Outdoor Unit : CU-3KS19NBU Indoor Unit : CS-MKS12NB4U × 3 Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > NOTE RATING CAPACITY: 18,300 BTU/h AIR FLOW RATE: 706 CFM INDOOR OUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) WB DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 18,680 18,570 18,560 18,620 18,490 72 (22.2) SHC 15,180 18,570 15,180 15,180 15,180 59 76 (24.4) SHC 17,510 18,570 17,510 17,510 17,510 (15.0) 80 (26.7) SHC 18,680 18,570 18,560 18,620...
Page 58
Outdoor Unit : CU-4KS24NBU Indoor Unit : CS-MKS9NKU × 3 Power Supply : 230V Single Phase 60Hz NOTE RATING CAPACITY: 25,400 BTU/h AIR FLOW RATE: 777 CFM INDOOR OUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 25,470 25,420 25,470 25,670 25,610 72 (22.2) SHC 19,250 25,420 19,250 19,410 19,410 59 76 (24.4) SHC 21,970 25,420 21,970 22,120 22,120 (15.0) 80 (26.7) SHC 24,840 25,420 24,840 24,840 24,840 84 (28.9) SHC 25,470 25,420...
Page 59
Outdoor Unit : CU-4KS24NBU Indoor Unit : CS-KS18NB4UW + CS-MKS12NB4U + CS-MKS12NB4U Power Supply : 230V Single Phase 60Hz RATING CAPACITY: 24,800 BTU/h AIR FLOW RATE: 812 CFM INDOOROUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 24,890 24,830 24,880 25,090 25,020 72 (22.2) SHC 19,360 24,830 19,360 19,520 19,520 59 76 (24.4) SHC 22,200 24,830 22,200 22,200 22,200 (15.0) 80 (26.7) SHC 24,890 24,830 24,880 25,090 25,020 84 (28.9)...
Page 60
Outdoor Unit : CU-4KS31NBU Indoor Unit : CS-MKS9NKU × 4 Power Supply : 230V Single Phase 60Hz RATING CAPACITY: 30,600 BTU/h AIR FLOW RATE: 1,036 CFM INDOOROUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) WB DB0515 25 35 45 55 (-17.8) (-15.0)(-9.4) (-3.9) (1.7) (7.2) (12.8) TC 30,870 30,760 30,800 31,010 30,890 72 (22.2) SHC 24,260 30,760 24,260 24,260 24,260 59 76 (24.4) SHC 27,890 30,760 27,890 27,890 27,890 (15.0) 80 (26.7) SHC 30,870 30,760 30,800 31,010 30,890 84 (28.9) SHC...