Outdoor Unit : CU-4KS31NBU Indoor Unit : CS-MKS9NB4U × 4 Power Supply : 230V Single Phase 60Hz RATING CAPACITY: 28,600 BTU/h AIR FLOW RATE: 883 CFM INDOOR OUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 28,890 28,790 28,810 28,990 28,870 72 (22.2) SHC 22,560 28,790 22,560 22,730 22,560 59 76 (24.4) SHC 25,980 28,790 25,810 25,980 25,980 (15.0) 80 (26.7) SHC 28,890 28,790 28,810 28,990 28,870 84 (28.9) SHC 28,890 28,790 28,810...
Page 62
6. ELECTRICAL DATA 6-1. Electric Wiring Diagrams Outdoor Unit CU-3KS19NBU 8FA2-5251-11800-1 62
Page 65
7. FUNCTIONS 7-1. Explanation of Functions The numerical values such as temperature, frequency, time and current in parentheses are an example of CU-4KS31NBU and the values are different from the other models. Control/conditions INITIAL Breaker is ON. Power is supplied to the indoor and outdoor unit control circuits, however the unit remains stopped. Positioning of the outdoor unit electric expansion valve is performed. The ON/OFF operation button on the remote controller is pressed.If automatic...
Page 66
Control/conditions COOL The ON/OFF operation button on the remote controller is pressed. The room temperature has reached the desired temperature.The outdoor unit does not operate for 3 minutes even after the breaker is turned ON. This is in order to stabilize the return of oil to the compressor. The outdoor unit starts. (Compressor and the outdoor fan start.) When the frequency reaches Hz, frequency increases are stopped for a period of seconds. (Refer to Table 1.) If the indoor and...
Page 67
Control/conditions SENSOR DRY (1/f fluctuation fan) The ON/OFF operation button on the remote controller is pressed.The outdoor unit does not operate for 3 minutes even after the breaker is turned ON. This is in order to stabilize the return of oil to the compressor. The outdoor unit starts. (Compressor and the outdoor fan start.) When the frequency reaches Hz, frequency increases are stopped for a period of seconds. (Refer to Table 1.) DRY B operation If the indoor and outdoor temperatures...
Page 68
< Low Ambient Cooling Operation > When the mode is switched from cooling opration to low ambient cooling operation, the compressor is stopped for 150 seconds temporarily. Outdoor fan speed [ rpm ] Outdoor air temperature32 °F ( °C ) When the mode has been switched to low ambient cooling operation, the outdoor fan speed is lowered as the outdoor air temperature falls. When the outdoor air temperature reaches 57.2 °F (14 °C ) or less during the cooling operation, the operation mode is switched to low...
Page 69
7-2. Protective Functions The numerical values such as temperature, frequency, time and current in parentheses are an example of CU-4KS31NBU and the values are different from the other models.NOTE 7-2-1. Current Control The operating current may rise as a result of causes including increasing cooling loads or decreases in power voltage. In these cases, the operating frequency is automatically reduced, or operation is stopped, in order to control the operating current so that it is (20 A) or less....
Page 70
Current(A) Frequency (Hz) Trip Hz reduction Hz increase prohibitHz reduction Hz increase prohibit Hz reduction Hz increase prohibit (16) (15.6) 0 (30)Example of operation during cooling The operating frequency upper limits shown in the figure below are established for frequency reduction and increase-prohibit. (2) Current control (230) (223) (212)Trip 5Hz every 30 sec. reduction 2Hz every 30 sec. reduction No controlIncrease prohibit range (Hz reduction) (°F) Compressor discharge temperature(194) Within...