Outdoor Unit : CU-4KE31NBU Indoor Unit : CS-MKE9NB4U × 4 Power Supply : 230V Single Phase 60Hz < Cooling Capacity (Low Ambient) > TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h) NOTE RATING CAPACITY: 28,600 BTU/h AIR FLOW RATE: 883 CFM INDOOROUTDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B DB 15 25 35 45 55 (-9.4) (-3.9) (1.7) (7.2) (12.8) TC 28,890 28,790 28,810 28,990 28,870 72 (22.2) SHC 22,560 28,790 22,560 22,730 22,560 59 76 (24.4) SHC 25,980 28,790 25,810 25,980 25,980 (15.0) 80 (26.7) SHC 28,890 28,790 28,810 28,990 28,870 84 (28.9) SHC 28,890 28,790 28,810 28,990 28,870 88 (31.1) SHC 28,890 28,790 28,810 28,990 28,870 TC 29,170 29,150 29,320 29,660 29,650 72 (22.2) SHC 18,440 29,150 18,440 18,610 18,610 63 76 (24.4) SHC 21,700 29,150 21,700 21,870 21,870 (17.2) 80 (26.7) SHC 25,130 29,150 25,130 25,300 25,300 84 (28.9) SHC 28,390 29,150 28,390 28,560 28,560 88 (31.1) SHC 29,170 29,150 29,320 29,660 29,650 TC 29,210 29,310 29,650 30,210 30,330 72 (22.2) SHC 14,160 29,310 14,330 14,500 14,500 67 76 (24.4) SHC 17,410 29,310 17,580 17,760 17,930 (19.4) 80 (26.7) SHC 20,840 29,310 21,010 21,180 21,360 84 (28.9) SHC 24,100 29,310 24,270 24,440 24,610 88 (31.1) SHC 27,360 29,310 27,530 27,870 27,870 TC 28,970 29,200 29,760 30,580 30,860 72 (22.2) SHC 9,700 29,200 9,870 10,210 10,210 71 76 (24.4) SHC 12,960 29,200 13,130 13,470 13,640 (21.7) 80 (26.7) SHC 16,380 29,200 16,560 16,900 17,070 84 (28.9) SHC 19,640 29,200 19,810 20,160 20,330 88 (31.1) SHC 22,900 29,200 23,240 23,410 23,580 TC 28,440 28,820 29,620 30,720 31,170 75 76 (24.4) SHC 8,500 28,820 9,010 9,360 9,530 (23.9) 80 (26.7) SHC 11,930 28,820 12,440 12,780 12,960 84 (28.9) SHC 15,360 28,820 15,700 16,040 16,210 88 (31.1) SHC 18,610 28,820 18,960 19,300 19,470 1. 2. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Freeze Prevention Protection during cooling operation into account. For this reason, the value may vary from the actual cooling characteristics. 61
Outdoor Unit : CU-3KE19NBU Indoor Unit : CS-MKE9NKU × 3 Power Supply : 230V Single Phase 60Hz < Heating Capacity > 5-4. Heating Capacity TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 24,800 BTU/h AIR FLOW RATE: 847 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 13,820 13,790 13,750 13,710 13,660 3 (-16.1) TH 14,280 14,250 14,220 14,170 14,120 8 (-13.3) TH 15,390 15,360 15,320 15,280 15,220 13 (-10.6) TH 16,540 16,510 16,470 16,420 16,360 18 (-7.8) TH 17,810 17,780 17,740 17,680 17,620 23 (-5.0) TH 19,150 19,110 19,070 19,010 18,930 28 (-2.2) TH 20,540 20,500 20,450 20,380 20,310 33 (0.6) TH 21,980 21,940 21,880 21,810 21,730 38 (3.3) TH 23,400 23,360 23,300 23,220 23,130 43 (6.1) TH 24,920 24,870 # 24,800 24,720 24,620 48 (8.9) TH 26,450 26,400 26,330 26,240 26,130 53 (11.7) TH 28,000 27,940 27,870 27,770 27,660 58 (14.4) TH 29,500 29,440 29,360 29,250 29,130 63 (17.2) TH 31,050 30,980 30,890 30,780 30,660 65 (18.3) TH 31,650 31,580 31,490 31,380 31,250 62
Outdoor Unit : CU-3KE19NBU Indoor Unit : CS-MKE12NB4U × 3 Power Supply : 230V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 24,000 BTU/h AIR FLOW RATE: 803 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 13,310 13,300 13,270 13,240 13,200 3 (-16.1) TH 13,760 13,740 13,720 13,690 13,650 8 (-13.3) TH 14,830 14,820 14,790 14,760 14,720 13 (-10.6) TH 15,950 15,930 15,910 15,870 15,830 18 (-7.8) TH 17,180 17,160 17,130 17,090 17,040 23 (-5.0) TH 18,470 18,450 18,420 18,380 18,320 28 (-2.2) TH 19,820 19,800 19,770 19,720 19,660 33 (0.6) TH 21,220 21,190 21,160 21,100 21,040 38 (3.3) TH 22,610 22,580 22,540 22,480 22,410 43 (6.1) TH 24,080 24,050 # 24,000 23,940 23,860 48 (8.9) TH 25,580 25,540 25,490 25,420 25,340 53 (11.7) TH 27,090 27,050 27,000 26,920 26,830 58 (14.4) TH 28,560 28,520 28,460 28,380 28,280 63 (17.2) TH 30,090 30,040 29,970 29,880 29,780 65 (18.3) TH 30,680 30,630 30,560 30,470 30,360 63
Outdoor Unit : CU-4KE24NBU Indoor Unit : CS-MKE9NKU × 3 Power Supply : 230V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 29,200 BTU/h AIR FLOW RATE: 847 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 16,550 16,540 16,510 16,470 16,420 3 (-16.1) TH 17,100 17,080 17,050 17,010 16,960 8 (-13.3) TH 18,390 18,370 18,340 18,300 18,250 13 (-10.6) TH 19,730 19,710 19,680 19,640 19,580 18 (-7.8) TH 21,200 21,180 21,150 21,100 21,040 23 (-5.0) TH 22,740 22,720 22,680 22,630 22,570 28 (-2.2) TH 24,330 24,310 24,270 24,220 24,150 33 (0.6) TH 25,970 25,950 25,900 25,850 25,770 38 (3.3) TH 27,580 27,560 27,510 27,450 27,370 43 (6.1) TH 29,280 29,250 # 29,200 29,130 29,050 48 (8.9) TH 30,990 30,950 30,900 30,830 30,740 53 (11.7) TH 32,690 32,650 32,600 32,520 32,270 58 (14.4) TH 34,320 34,280 34,220 34,140 32,580 63 (17.2) TH 35,970 35,930 35,860 35,420 32,770 65 (18.3) TH 36,600 36,560 36,500 35,460 32,800 64
Outdoor Unit : CU-4KE24NBU Indoor Unit : CS-KE18NB4UW + CS-MKE12NB4U + CS-MKE12NB4U Power Supply : 230V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 28,400 BTU/h AIR FLOW RATE: 918 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 16,030 16,040 16,050 16,040 16,020 3 (-16.1) TH 16,550 16,560 16,570 16,560 16,540 8 (-13.3) TH 17,790 17,810 17,820 17,810 17,790 13 (-10.6) TH 19,080 19,100 19,110 19,100 19,090 18 (-7.8) TH 20,500 20,520 20,530 20,530 20,510 23 (-5.0) TH 21,990 22,010 22,020 22,010 22,000 28 (-2.2) TH 23,530 23,560 23,570 23,560 23,540 33 (0.6) TH 25,130 25,150 25,160 25,150 25,130 38 (3.3) TH 26,700 26,730 26,740 26,730 26,700 43 (6.1) TH 28,360 28,390 # 28,400 28,390 28,360 48 (8.9) TH 30,050 30,070 30,080 30,070 30,040 53 (11.7) TH 31,740 31,770 31,780 31,770 31,530 58 (14.4) TH 33,370 33,400 33,410 33,400 32,030 63 (17.2) TH 35,050 35,080 35,090 35,070 32,450 65 (18.3) TH 35,700 35,730 35,740 35,400 32,570 65
Outdoor Unit : CU-4KE31NBU Indoor Unit : CS-MKE9NKU × 4 Power Supply : 230V Single Phase 60Hz < Heating Capacity > TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 32,000 BTU/h AIR FLOW RATE: 1,130 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 17,980 17,970 17,950 17,910 17,870 3 (-16.1) TH 18,570 18,560 18,540 18,510 18,460 8 (-13.3) TH 19,990 19,980 19,950 19,920 19,870 13 (-10.6) TH 21,450 21,440 21,420 21,380 21,330 18 (-7.8) TH 23,060 23,050 23,030 22,990 22,940 23 (-5.0) TH 24,760 24,750 24,720 24,680 24,620 28 (-2.2) TH 26,520 26,510 26,480 26,430 26,370 33 (0.6) TH 28,340 28,330 28,300 28,250 28,180 38 (3.3) TH 30,140 30,130 30,100 30,040 29,970 43 (6.1) TH 32,050 32,040 # 32,000 31,940 31,870 48 (8.9) TH 33,990 33,970 33,930 33,870 33,790 53 (11.7) TH 35,940 35,920 35,880 35,820 35,730 58 (14.4) TH 37,820 37,800 37,760 37,690 37,600 63 (17.2) TH 39,770 39,750 39,700 39,630 39,530 65 (18.3) TH 40,520 40,500 40,460 40,380 40,290 66
Outdoor Unit : CU-4KE31NBU Indoor Unit : CS-MKE9NB4U × 4 Power Supply : 230V Single Phase 60Hz TH : Total Heating Capacity (BTU/h) 1. Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB : Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB 2. 3. Above data represents the value when the operation frequency of a compressor is fixed.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics. NOTE RATING CAPACITY: 32,000 BTU/h AIR FLOW RATE: 1,000 CFM OUTDOORINDOOR ENT. TEMP. oF (oC) AMBIENT TEMP. oF (oC) W B 60 65 70 75 80 (15.6) (18.3) (21.1) (23.9) (26.7) 0 (-17.8) TH 17,910 17,890 17,850 17,810 17,750 3 (-16.1) TH 18,510 18,480 18,450 18,400 18,340 8 (-13.3) TH 19,940 19,920 19,880 19,830 19,770 13 (-10.6) TH 21,420 21,400 21,360 21,310 21,240 18 (-7.8) TH 23,050 23,030 22,980 22,930 22,860 23 (-5.0) TH 24,760 24,730 24,690 24,630 24,550 28 (-2.2) TH 26,540 26,510 26,460 26,390 26,310 33 (0.6) TH 28,380 28,340 28,290 28,220 28,130 38 (3.3) TH 30,190 30,150 30,090 30,020 29,920 43 (6.1) TH 32,110 32,060 # 32,000 31,920 31,810 48 (8.9) TH 34,050 34,000 33,930 33,840 33,720 53 (11.7) TH 36,000 35,940 35,870 35,770 35,650 58 (14.4) TH 37,870 37,810 37,730 37,630 37,500 63 (17.2) TH 39,790 39,730 39,640 39,530 39,390 65 (18.3) TH 40,540 40,480 40,390 40,270 40,130 < Heating Capacity > 67
6. ELECTRICAL DATA 6-1. Electric Wiring Diagrams Outdoor Unit CU-3KE19NBU 8FA2-5251-11700-1 68