Page 11
3.3. CS-W12DKR CU-W12DKR UnitCS-W12DKRCU-W12DKR Cooling CapacitykW (kcal/h)3.60 (3,100) - 3.60 (3,100) BTU/h12,300 - 12,300 Heating CapacitykW (kcal/h)3.90 (3,350) - 3.90 (3,350) BTU/h13,300 - 13,300 Moisture Removall/h (Pint/h)2.1 (4.4) PhaseøSingle Power SourceVoltageV230 - 240 CycleHz50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeLom3/min (cfm)Cooling; 6.7 (236) - 6.7 (236)— Heating; 7.1 (251) - 7.1 (251) Mem3/min (cfm)Cooling; 8.3 (294) - 8.3 (294)— Heating; 8.3 (294) - 8.3 (294) Him3/min...
Page 12
UnitCS-W12DKRCU-W12DKR DimensionsHeightinch (mm)11 - 1/32 (280)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)7 - 7/32 (183)11 - 3/8 (289) Net Weightlb (kg)20 (9.0)77 (35) CompressorDescription—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—900 Air CirculationDescriptionCross-flow FanPropeller Fan MaterialASG20k1PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW4773 RatedOutputW1533 Fan SpeedLowrpmCooling; 900 - 900— Heating;...
Page 13
4 Dimensions 4.1. Indoor Unit & Remote Control 4.1.1. CS-W7DKR CS-W9DKR CS-W12DKR 13 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
Page 14
4.2. Outdoor Unit 4.2.1. CU-W7DKR CU-W9DKR 4.2.2. CU-W12DKR 14 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
Page 15
5 Refrigeration Cycle Diagram 15 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
Page 20
8 Operation Details 8.1. Heating Operation • Heating operation can be set using remote control. • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control. • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C to 30°C. • During heating operation, the compressor will stop running and restart as shown in below figure. 8.1.1. Heating Operation Time Diagram 20 CS-W7DKR CU-W7DKR...