1 Features 3 2 Functions 4 2.1. Remote Control 4 2.2. Indoor Unit 5 2.3. Outdoor Unit 6 3 Product Specifications 7 3.1. CS-W7DKR CU-W7DKR 7 © 2004 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-W7DKR CU-W7DKR CS-W9DKR CU-W9DKR CS-W12DKR CU-W12DKR 3.2. CS-W9DKR CU-W9DKR 9 3.3. CS-W12DKR CU-W12DKR 11 4 Dimensions 13 4.1. Indoor Unit & Remote Control 13 4.2. Outdoor Unit 14 5 Refrigeration Cycle Diagram 15 6 Block Diagram 16 Air Conditioner CONTENTS Page Page Order No. MAC0411051C3
7 Wiring Diagram 18 8 Operation Details 20 8.1. Heating Operation 20 8.2. Cooling Operation 21 8.3. Soft Dry Operation 22 8.4. Automatic Operation 23 8.5. Operation Control 24 8.6. Indoor Fan Speed Control 30 8.7. Outdoor Fan Speed Control 32 8.8. Vertical Airflow Direction Control 32 8.9. Horizontal Airflow Direction Control 33 8.10. Powerful Operation 33 8.11. Quiet Operation 35 8.12. Ionizer Operation 37 8.13. Timer Control 38 8.14. Random Auto Restart Control 38 8.15. Remote Control Signal Receiving Sound 38 9 Operating Instructions 39 10 Installation Instructions 45 10.1. Safety Precautions 45 10.2. Indoor Unit 48 10.3. Outdoor Unit 52 11 Installation And Servicing Air Conditioner Using R410A 55 11.1. Outline 55 11.2. Tools For Installing/Servicing Refrigerant Piping 56 11.3. Refrigerant Piping Work 60 11.4. Installation, Transferring, Servicing 62 12 Servicing Information 66 12.1. Distinction Of Lead Free (PbF) Printed Circuit Board 66 12.2. Indoor Electronic Controllers Removal Procedures 66 12.3. Indoor Fan Motor And Cross Flow Fan Removal Procedures 67 12.4. Remote Control Reset 68 12.5. Auto OFF/ON Button 69 13 Troubleshooting Guide 70 13.1. Refrigeration Cycle System 70 13.2. Relationship Between The Condition Of The Air Conditioner And Pressure And Electric Current 71 13.3. Diagnosis Methods Of A Malfunction Of A Compressor And 4-way Valve 71 14 Technical Data 72 14.1. Thermostat Characteristics 72 14.2. Sensible Capacity Chart 73 14.3. Operation Characteristics 74 15 Exploded View (Indoor Unit) 77 15.1. CS-W7DKR CS-W9DKR CS-W12DKR 77 16 Replacement Parts List (Indoor Unit) 78 16.1. CS-W7DKR CS-W9DKR CS-W12DKR 78 17 Exploded View (Outdoor Unit) 79 17.1. CU-W7DKR CU-W9DKR 79 17.2. CU-W12DKR 80 18 Replacement Parts List (Outdoor Unit) 81 18.1. CU-W7DKR CU-W9DKR 81 18.2. CU-W12DKR 82 19 Electronic Circuit Diagram 83 19.1. Indoor Unit & Outdoor Unit 83 19.2. Remote Control 89 19.3. Print Pattern Indoor Unit Printed Circuit Board 90 19.4. Print Pattern Indicator & Receiver Printed Circuit Board 92 2 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
• High efficien cy. • Compact design. • W ider range of horizontal discharge air. • Air Filter with function to reduce dust and smoke. • Long installation piping up to 15 meter (CS/CU-W12DK R), 10 meter (CS/CU-W7DKR & CS/CU-W9DKR). • Supersonic Air Purifyin g System with Super Alleru-Buster. − Inactive various harmful airbone elements includin g allergens, viruses and bacteria. − Generated supersonic waves enhanc e the ability to collect dust and dirt in the air. • Quality Improvement − Random auto restart after power failure for safety restart operation. − Gas leakage detection. − Prevent Compressor reverse cycle. − OLP to protect Compressor. − Noise prevention during soft dry operation. − Blue coated Conden ser for high resistance to corrosion. − Anti-dew formation control (Cooling & Soft Dry). − Overload protection control (Heating) − Outdoor fan control. − Compressor high pressure control. • Operation Improvement − Quiet mode to provide quiet operation. − Powerful mode to reach the desired room temperature quickly. − Ionizer control for generating negative ion in discharge air. − 24-hour timer setting. • Servicea bility Improvement − Removable and washable Front Panel. • Environmental Friendly − R410A, which does not contain chlorine , is used as its refrigerant, so there is no danger of damage to the ozone layer in Stratosphere. 1 Features 3 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
2 Functions 2.1. Remote Control Operation Start / StopOFF / ON IRoom Temperature SettingTEMP. Operation Mode Selection •AUTOAutomatic Operation • HEATHeating Operation • COOLCooling Operation • DRYSoft Dry Operation MODE Time / Timer Setting • Hours and minutes setting. Clock Setting • Current time setting. Ionizer Operation Start / Stop Indoor Fan Speed SelectionFAN SPEED •Low Fan Speed • Medium Fan Speed • High Fan Speed • AUTOAutomatic Fan Speed Vertical Airflow Direction Control • 24-hour, OFF / ON Real Timer Setting. ON-TIMER OFF-TIMER Timer Operation Selection SET CANCEL Timer Operation Set / Cancel • ON Timer and OFF Timer setting and cancellation. CLOCK AIR SWING •AUTOAutomatic Vertical Airflow Control. • Manual Vertical Airflow Control (5 stages of adjustment). Powerful Operation Start / StopPOWERFUL Quiet Operation Start / StopQUIET Heating, Cooling, Soft Dry Operation. • Increase or decrease set temperature (16°C to 30°C) Automatic Operation • Operation with 2°C higher than standard temperature. • Operation with standard temperature. • Operation with 2°C lower than standard temperature. CANCEL OFF TIMERON TIMER FA N SPEED AIR SWINGAUTO HEAT DRY COOL MODE TIMER ON 123 OFF CLOCK RESET SET CANCEL TEMP POWERFULFAN SPEED AIR SWING OFF/ON QUIET 4 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
2.2. Indoor Unit Automatic Operation Button •Press for < 5 second to operate Automatic operation mode. Used when the remote control cannot be used. •Press for ≥ 5 second to operate Cooling operation mode and compressor force to on (“beep” sound will heard). Used when test running or servicing. •Within 20 second of Cooling operation, press continuously for 5 second to enter various setting mode. “beep, beep” sound will be heard. (Used to toggle remote control signal receiving sound or select remote control transmission code). AUTO OFF / ON Operation Indication Lamps (LED) 7 Minutes Time Save Control •To reduce the built up humidity inside the room. Anti-Dew Formation Control •Anti-Dew Formation Control for indoor unit discharge area. Timer Operation •Delay OFF/ON Timer control. Powerful Operation •Reaches the desired room temperature quickly. Anti-Freezing Control •To prevent indoor heat exchanger from freezing. Random Auto Restart Control •Unit will be restarted, when resume from power failure, at previous setting. Indoor Fan Speed Control •Manual control fan speed (High, Medium and Low). •Automatic fan speed. •Vertical airflow control can be adjusted automatically or manually by remote control. •Horizontal airflow can be manually adjusted by hand. Airflow Direction Control Time Delay Safety Control •Restarting is inhibited for appro. 3 minutes. Hot-Start Control •To prevent cold air being discharge during Heating operation starts. Starting Current Control •To reduce the starting current. Anti Cold Draft Control •To prevent the cold draft during Heating mode operation in thermo off condition. Operation Mode •Heating, Cooling, Soft Dry and Automatic Operation. 30 Minutes Time Save Control •Heating operation only. Quiet Operation •To provide quiet operation. Ionizer Operation •Generate and discharge negative ion. •POWER (Green) ............. Lights up in operation, blinks in Automatic Operation judging and Hot Start operation. •TIMER (Orange) ............ Lights up in Timer Setting. •QUIET (Orange) ............. Lights up in Quiet Operation. •POWERFUL (Orange) ...... Lights up in Powerful Operation. •ION (Green) .................. Lights up in Ionizer Operation. •SUPER ALLERU-BUSTER (Blue) ... Lights up in operation. 5 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
2.3. Outdoor Unit •To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control •Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector •OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows to compressor. (Refer circuit diagram for OLP characteristic) Compressor Reverse Rotation Protection Control Outdoor Fan Operation Control •Temperature Fuse. 4-Way Valve Control •When the unit is switched to “OFF” during Heating Operation, 4-way valve stays at Heating position for 5 minutes. Overload Protection Control •Outdoor fan stops when indoor heat exchanger temperature rises to 51°C and above, and restarts when the indoor heat exchanger temperature drops to 49°C and below. •Compressor stop when indoor heat exchanger temperature reaches 65°C or above. (Heating Operation Only) Deice Control •To prevent frosting at outdoor heat exchanger. (Only for Heating Operation) • Temperature of outdoor heat exchanger is sensed by TRS (Thermal Reed Switch). TRS OFF temperature 4°C. TRS ON temperature -3°C. Compressor Protection Control •If the outdoor fan motor is not running after compressor starts for 50 secs., compressor will stop. (Cooling and Soft Dry Operation only). 6 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
3 Product Specifications 3.1. CS-W7DKR CU-W7DKR UnitCS-W7DKRCU-W7DKR Cooling CapacitykW (kcal/h)2.30 (1,980) - 2.30 (1,980) BTU/h7,840 - 7,840 Heating CapacitykW (kcal/h)2.45 (2,110) - 2.45 (2,110) BTU/h8,350 - 8,350 Moisture Removall/h (Pint/h)1.5 (3.2) PhaseøSingle Power SourceVoltageV230 - 240 CycleHz50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeLom3/min (cfm)Cooling; 5.8 (203) - 5.8 (203)— Heating; 6.3 (220) - 6.3 (220) Mem3/min (cfm)Cooling; 6.9 (245) - 6.9 (245)— Heating; 7.0 (250) - 7.0 (250) Him3/min (cfm)Cooling; 7.9 (280) - 7.9 (280)Cooling; 26.0 (920) - 27.0 (950) Heating; 9.1 (320) - 9.1 (320) SHim3/min (cfm)Cooling; 9.0 (318) - 9.0 (318)— Heating; 9.0 (318) - 9.0 (318) Noise LeveldB (A)Cooling; High 34 - 34, Low 26 - 26Cooling; High 46 - 47 Heating; High 36 - 36, Low 26 - 26Heating; High 48 - 49 Power level dBCooling; High 47 - 47Cooling; High 61 - 62 Heating; High 49 - 49Heating; High 63 - 64 Electrical DataInputWCooling; 710 - 720 Heating; 675 - 685 Running CurrentACooling; 3.2 - 3.2 Heating; 3.0 - 3.0 EERW/W (BTU/hW)Cooling; 3.24 - 3.19 (11.0 - 10.9) COPW/W (BTU/hW)Heating; 3.63 - 3.58 (12.4 - 12.2) Starting CurrentA12.0 Piping Connection Port (Flare piping)inch inchG ; Half Union 3/8” L ; Half Union 1/4”G ; 3-way valve 3/8” L ; 2-way valve 1/4” Pipe Size (Flare piping)inch inchG ; (gas side) 3/8” L ; (liquid side) 1/4”G ; (gas side) 3/8” L ; (liquid side) 1/4” Drain HoseInner diametermm12— Lengthmm650— 7 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
UnitCS-W7DKRCU-W7DKR Power Cord Length Number of core-wirem1.9 3 (1.5 mm2)— — DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510) Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650) Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230) Net Weightlb (kg)20 (9.0)57 (26) CompressorDescription—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—600 Air CirculationDescriptionCross-flow FanPropeller Fan MaterialASG20k1PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW4768 RatedOutputW1530 Fan SpeedLowrpmCooling; 780 -780— Heating; 840 - 840 MediumrpmCooling; 940 - 940— Heating; 940 - 940 HighrpmCooling; 1,070 - 1,070815 - 830 Heating; 1,220 - 1,220 SuperHighrpmCooling; 1,220 - 1,220— Heating; 1,220 - 1,220 Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium (Blue Coat) Fin TypeSlit FinCorrugate Fin Row / Stage(Plate fin configuration, forced draft) 2×152×23 FPI2117 Size (W × H × L)mm610 × 315 × 25.4585.7 557.1× 483 × 36.4 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—FV50S (300) Refrigerant (R-410A)g (oz)—910 (32.1) ThermostatElectronic Control— Protection Device—Overload Protector Capillary TubeLengthmm—Cooling; 955, Heating; 415 Flow Ratel/min—Cooling; 6.5, Heating; 9.6 Inner Diametermm—Cooling; 2.6, Heating; 2.6 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—20 µF, 400VAC Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC • Specifica tions are subject to change without notice for further improvement. 8 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
3.2. CS-W9DKR CU-W9DKR UnitCS-W9DKRCU-W9DKR Cooling CapacitykW (kcal/h)2.75 (2,370) - 2.75 (2,370) BTU/h9,380 - 9,380 Heating CapacitykW (kcal/h)3.05 (2,620) - 3.05 (2,620) BTU/h10,400 - 10,400 Moisture Removall/h (Pint/h)1.6 (3.4) PhaseøSingle Power SourceVoltageV230 - 240 CycleHz50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeLom3/min (cfm)Cooling; 5.8 (203) - 5.8 (203)— Heating; 6.2 (220) - 6.2 (220) Mem3/min (cfm)Cooling; 7.3 (257) - 7.3 (257)— Heating; 7.3 (257) - 7.3 (257) Him3/min (cfm)Cooling; 8.6 (300) - 8.6 (300)Cooling; 26.0 (920) - 27.0 (950) Heating; 9.7 (340) - 9.7 (340) SHim3/min (cfm)Cooling; 9.7 (343) - 9.7 (343)— Heating; 9.7 (343) - 9.7 (343) dB (A)Cooling; High 36 - 36, Low 26 - 26Cooling; High 48 - 49 Heating; High 39 - 39, Low 26 - 26Heating; High 49 - 50 Noise Level Power level (dB)Cooling; High 49 - 49Cooling; High 63 - 64 Heating; High 52 - 52Heating; High 64 - 65 Electrical DataInputWCooling; 855 - 875 Heating; 845 - 865 Running CurrentACooling; 3.8 - 3.8 Heating; 3.8 - 3.8 EERW/W (BTU/hW)Cooling; 3.22 - 3.14 (11.0 - 10.7) COPW/W (BTU/hW)Heating; 3.61 - 3.53 (12.3 - 12.0) Starting CurrentA17.2 Piping Connection Port (Flare piping)inch inchG ; Half Union 3/8” L ; Half Union 1/4”G ; 3-way valve 3/8” L ; 2-way valve 1/4” Pipe Size (Flare piping)inch inchG ; (gas side) 3/8” L ; (liquid side) 1/4”G ; (gas side) 3/8” L ; (liquid side) 1/4” Drain HoseInner diametermm12— Lengthmm650— Power Cord Length Number of core-wirem1.9 3 (1.5 mm2)— — 9 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
UnitCS-W9DKRCU-W9DKR DimensionsHeightinch (mm)11 - 1/32 (280)20 - 3/32 (510) Widthinch (mm)31 - 15/32 (799)25 - 19/32 (650) Depthinch (mm)7 - 7/32 (183)9 - 1/16 (230) Net Weightlb (kg)20 (9.0)64 (29) CompressorDescription—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—700 Air CirculationDescriptionCross-flow FanPropeller Fan MaterialASG20k1PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW4768 RatedOutputW1530 Fan SpeedLowrpmCooling; 780 - 780— Heating; 840 - 840 MediumrpmCooling; 980 - 980— Heating; 980 - 980 HighrpmCooling; 1,160 - 1,160815 - 830 Heating; 1,310 - 1,310 SuperHighrpmCooling; 1,310 - 1,310— Heating; 1,310 - 1,310 Heat ExchangerDescriptionEvaporatorCondenser Tube materialCopperCopper Fin materialAluminium (Pre Coat)Aluminium (Blue Coat) Fin TypeSlit FinCorrugate Fin Row / Stage(Plate fin configuration, forced draft) 2×152×23 FPI2117 Size (W×H×L)mm610×315×25.4585.7 557.1×483×36.4 Refrigerant Control Device—Capillary Tube Refrigeration Oil(cm3)—FV50S (350) Refrigerant (R-410A)g (oz)—950 (33.5) ThermostatElectronic Control— Protection Device—Overload Protector Capillary TubeLengthmm—Cooling; 475, Heating; 330 Flow Ratel/min—Cooling; 7.2, Heating; 10.7 Inner Diametermm—Cooling; 2.6, Heating; 2.6 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—30 µF, 370VAC Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC • Specifica tions are subject to change without notice for further improvement. 10 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR