    							 • Auto Fan Speed during cooling operation:
     1. Indoor fan will rotate alternately between off and on as shown in below diagram.
     2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
     3. For the first time the compressor operate, indoor fan will be switched to Hi fan speed from Lo- after 70 seconds from the
    start of compressor. This cause the room temperature to achieve the setting temperature quickly.
     4. During compressor stop, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher volume of refrigerant
    in liquidform returning to the compressor.
     5. After the compressor at turn off conditio n for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the room.
    This is to obtain the actual reading of the intake air temperature.
     6. When the compressor resume operation, indoor fan will operate at Me fan speed (after 70 seconds from the restart of
    compressor) to provide comfort and lesser noise environment.
     • Auto Fan Speed during Soft Dry operation:
     1. Indoor fan will rotate alternately between off and Lo-.
     2. At the beginning of each compressor start operation, indoor fan will increase fan speed gradually for deodorizing purpose.
     3. When compressor at turn off conditio n for 6 minutes, indoor fan will start fan speed at Lo- to circulate the air in the room.
    This is to obtain the actual reading of intake air temperature.
    31
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							(Cooling and Soft Dry Operation condition)
     • W hen the vertical airflow direction is set to Auto using the
    remote control, the louver swings up and down as shown in
    the diagram.
     • W hen stop operation using the remote control, the
    discharge vent is reset, and stop at the closing position .
     • During Cooling operation or Soft Dry operation, indoor fan
    motor may stop to rotate at certain periods. At that
    conditio n, the louver will stop swinging and rest at the upper
    limit.
     • During Anti-dew conden sation prevention, Airflow Direction
    Auto-control angle change from 0°-32°to 20°-30°under
    Cooling and Soft Dry operation mode.Cooling and Soft Dry Operation
     • Auto Fan Speed during Heating operation.
     1. Indoor fan will rotate in the range of SLo
    →Me according to the heat exchanger temperature.
    8.6.3. Manual Fan Speed Control
     • Manual fan speed adjustment can be carried out by using the Fan Speed selection button at the remote control.
     • There are 3 types of fan speed settings: Lo, Me, Hi.
    8.7. Outdoor Fan Speed Control
     • There is only one speed for outdoor fan motor.
     • W hen the air conditio ner is turned on, the compressor and the outdoor fan will operate simultaneously .
     • Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
    8.8. Vertical Airflow Direction Control
    8.8.1. AutoControl
    32
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							(Heating Operation condition)
     • W hen the piping air temperature reaches 38°C, the
    louver is changed from upper to lower limit.When the
    piping air temperature falls to 35°C, the louver is
    changed from lower to upper limit.
    Cooling and Soft Dry Operation
    (Cooling and Soft Dry Operation condition)Heating Operation
    Heating Operation
    8.8.2. Manual Control
     • W hen the vertical airflow direction is set to Manua l using the remote control, the automatic airflow is released and the airflow
    direction louver move up and down in the range shown in the diagram.
     • The louver can be adjusted by pressing the button to the desired louver position .
     • W hen stop operation using the remote control, the discharge vent is reset, and stop at the closing position .
     • During Anti-dew conden sation prevention, Airflow Direction Manua l control angle changefrom 10°,15°,20°,26°,32°to 22°,
    24°,26°,28°,30°under Cooling and Soft Dry operation mode.
    8.9. Horizontal Airflow Direction Control
     • The horizontal airflow direction louvers can be adjusted manually by hand.
    8.10. Powerful Operation
     • The Powerful operation is to achieve the setting temperature quickly.
     • W hen Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
    setting temperature (Lower temperature limit: 16°C).
     • This operation automatically will be running under SHi Fan Speed (Cooling).
     • Vertical Airflow Direction:-
    -In“Manual”setting, the vane will automatically shift down 10°lower than previous.
    -In“Auto”setting, the vane will automatically swing up and down. However the lower limit will be shifted 10°downward.
    (Heating Operation condition)
     • W hen Powerful operation is set, the setting temperature will be automatically increased 3°C against the present setting
    temperature (Higher temperature: 30°C).
     • The Fan Speed will shift as shown below:
    33
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							 • Vertical Airflow Direction:-
     − In“Manual”setting, the vane will automatically shift down 5°lower than previous setting.
     − In“Auto”setting, the vane will automatically shift between upper and lower limit depend ing on the intake air temperature
    as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5°downward.
     • Powerful operation stops when:-
     − Powerful operation has operate for 15 minutes.
     − Powerful button is pressed again.
     − Quiet button is pressed.
     − Stopped by OFF/ON operation button.
     − Timer OFF activates.
     − Operating mode is changed.
    34
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							8.11. Quiet Operation
     • The Quiet operation is to provide quiet cooling/heatin g operation conditio n compare to normal operation.
    (Cooling and Soft Dry Operation condition)
     • Once the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
    2 dB(A) for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present sound level operation.
     • Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo
    + 80 rpm). After that, it goes back to QLo+160 (However Quiet LED remains on).
     • Manual Fan Speed: -
     − RPM control during Lo cool
     − RPM control during Hi & Me cool
     • Auto Fan Speed: -
     − Cooling operation
     − Soft Dry operation
    35
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							(Heating Operation condition)
     • W hen the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
    2 dB (Lo) or 3 dB (Hi, Me), against the present sound level operation.
     • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
     • Manual Fan Speed: -
     − Rpm control during Lo, Me & Hi Cool
     • Auto Fan Speed: -
     − Rpm control depend s on the piping air temperature sensor of Indoor heat exchan ger
     • Quiet operation stops when:-
     − Quiet button is pressed again.
     − Powerful button is pressed.
     − Stopped by OFF/ON operation button.
     − Timer OFF activates.
    36
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							8.12. Ionizer Operation
     • The Ionizer operation is to provide fresh air effect to user by producing minus ion in discharge air.
    8.12.1. Operation Control
     1. Ionizer individu al operation
     a. When air-conditioner unit is at“OFF”conditio n (standby) and ION operation button at the remote control is pressed, the
    Ionizer and indoor fan operations will turn on. Only ION LED will illuminates. Power LED maintainoff. (1
    →2)
     b. Ionizer individu al operation can be turned off by pressing the ION button again. (2
    →1)
     c. Fan speed can be adjusted later by customer during this operation.
     d. Vertical airflow direction can be adjusted using remote control during Ionizer individu al operation.
     e. During Ionizer individu al operation, operated mode (Auto, Cool, Dry, Heat) can be activated by turning on the OFF/ON
    operation button. (2
    →4)
     f. If power failure occur during Ionizer individu al operation, after power resume, Ionizer operation will be activated immediately.
     g. When theIonizer circuit feedba ck process error occur for 24 times (about 11hr 30 min.), Ionizer and Air Circulation
    operations will turn off with ION LED blinks continuously.
    (For details, please refer to Ionizer Error detection control)
     2. Operation mode & Ionizer operation.
     a. When air-conditioner unit is at“ON”conditio n and ION operation button at the remote control is pressed, the Ionizer
    operation will turn on. ION & Power LED will illuminate. (3
    →4)
     b. Ionizer operation stops when:
     • ION operation button is press again.
     • Stopped by OFF/ON operation button.
     • Timer OFF activates.
     • Ionizer circuit feedba ck signal shows error.
     c. Ionizer operation status is not memorized when the air conditio ner has been switched off. The air-conditio ner will operate
    without ionizer operation when it is turned on again. However, if power failure occurs during Ionizer operation together with
    Cooling operation, air-conditioner will start to operate at Cooling operation with Ionizer operation when the power is
    resumed.
    37
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							8.12.2. Error Detection Control
     • The error detection control is to inform user that error occurs at ionizer system and repairing job will be needed .
     • There are two types of error detection control:
    a. WhenIonizer is ON
     − If ionizer feedba ck = Lo for 24 times within 11hr 30min, ION LED blinks continuously.
    b. Whenionizer is OFF
     − If ionizer feedba ck = Hi, ION LED blinks continuously.
     • During ionizer at breakdown conditio n, if ionizer feedba ck voltage = Lo (become normal), ION LED will stop blinking.
     • The error detection control can be reset by:
    i) Pressing the OFF/ON operation button to switch the operation OFF.
    ii) Pressing the Auto Operation button to force the operation OFF.
    iii) Setting the OFF Timer to stop the operation (Not applica ble when ionizer is OFF).
    8.13. Timer Control
     • There are 2 types of timer, ON and OFF timer.
     • Both ON and OFF timer can be set by pressing ON or OFF button respectively.
     • By pressing ON/OFF operation button, ON Timer or OFF Timer will not be cancelled.
     • To cancel the previous timer setting, press CANCEL button.
     • To activate the previous timer setting, press SET button once again.
     • If main power supply is switchedoff, the timer setting will be cancelled.
    8.13.1. ON Timer
     • W hen ON Timer is set by using the remote control, the unit will start to operate slightly before the set time, so that the room will
    reach nearly to the set temperature by the set time.
     • For Cooling and Soft Dry operation, the operation will start 15 minutes before the set time.
     • For Heating operation, the operation will start 30 minutes before the set time.
     • For Automatic operation, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
    intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
    8.13.2. OFF Timer
     • W hen OFF Timer is set by using the remote control, the unit will stop operate according to the desired setting.
    8.14. Random Auto Restart Control
     • If there is a power failure during operation, the air conditio ner will automatically restart after 3 to 4 minutes when the power is
    resumed.
     • It will start with previous operation mode and airflow direction.
     • If there are more than one air conditio ner unit in operation and power failure occur, restart time for each unit to operate will be
    decided randomly using 4 parameters:- intake air temperature, setting temperature, fan speed and air swing louver position .
     • This Random Auto Restart Control is not available when Timer is set.
     • This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
    8.15. Remote Control Signal Receiving Sound
     • Long beep sound will be heard when:-
     − Stopping the air conditio ner using OFF/ON operation button.
     − Stopping the Quiet Mode.
     − Stopping the Powerful Mode.
     − Stopping the Ion Mode.
     • Short beep sound will be heard for others setting.
    38
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							9 Operating Instructions
    (GB Standard)
    This sign warns of death 
    or serious injury.
    The appliance is not intended for use by young children or infi rm 
    person without supervision. Young children should be supervised to 
    ensure that they do not play with the appliance.
    Replacement or installation of power plugs shall be performed by 
    authorized/qualifi ed personnel only. The wires in this mains lead are 
    coloured in accordance with the following code: To prevent personal injury, 
    injury to others and property 
    damage, the following 
    instructions must be 
    followed.
    Incorrect operation due to 
    failure to follow instructions 
    will cause harm or damage, 
    the seriousness of which is 
    classifi ed as below:
    Thank you for purchasing Panasonic Air Conditioner
    SAFETY PRECAUTIONS
    This symbol denotes 
    an action that is 
    PROHIBITED.
    These symbols denote 
    actions that are 
    COMPULSORY.
    Warning
     Definition
    This sign warns of injury 
    or damage to property.
    Caution
    The instructions to be 
    followed are classifi ed by 
    the following symbols:
    Safety RegulationOperation Condition (OC)
    Use this air conditioner under the following temperature 
    range.
    DBT: Dry Bulb Temperature
    WBT: Wet Bulb TemperatureIndoor Outdoor
    DBT WBT DBT WBT
    Maximum Temperature (COOL)32 23 43 26
    Maximum Temperature (HEAT)30 – 24 18
    Minimum Temperature (COOL)16 11 16 11
    Minimum Temperature (HEAT)1 6 – - 5 - 6            
    Different countries may have different colour coding for the wires.
    Installation PrecautionsInstallation Precautions
    Caution
    •  Do not pull the cord to 
    disconnect the plug.
    •  Do not wash the unit with water, benzene, 
    thinner or scouring powder.
    •   Do not use for other purposes such as 
    preservation of food.
    •  Do not use any combustible equipment at 
    airfl ow direction.
    •  Do not sit or place anything on the indoor 
    or outdoor unit.
    •  Do not expose directly to cold air for a 
    long period.•  Ventilate the room regularly.
    •  Pay attention as to whether the 
    installation rack is damaged after long 
    period of usage.
    •  Switch off the power supply and unplug 
    before cleaning or servicing.
    •  Turn off the power supply and unplug if 
    the unit is not used for a long period of 
    time.
    OperationOperation Precautions Precautions
    Warning
    Do not install, remove and reinstall the unit by yourself.
    •  Improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or 
    specialist for the installation work.
    Caution
    •  This air conditioner must be earthed. Improper grounding will cause electric shock.
    •  Ensure that the drainage piping is connected properly. Otherwise, water will leak.
    •  Current leakage protection equipment must be installed. Otherwise, electric shock or fi re may 
    occur.
    •  Do not install the unit in a potentially explosive atmosphere.
    •  Insert the power plug properly.
    •  Use specifi ed supply cord.
    •  If the supply cord is damaged or needed 
    to be replaced, it must be replaced by 
    the manufacturer or its service agent or 
    a similarly qualifi ed person in order to 
    avoid a hazard.
    •  Remove the batteries if the unit is not 
    going to be use for a long period of time.
    •  
    New batteries of the same type must be 
    inserted following the polarity stated to 
    prevent malfunction of the remote control.
    •  In case of emergency or abnormal 
    condition (burnt, smell, etc) occurs, turn 
    off the power supply and unplug.
    Warning
    •  Do not share power outlet.
    •  Do not modify power cord.
    •  Do not use an extension cord.
    •  Do not operate with wet hands.
    •  Do not operate or stop the unit by inserting 
    or pulling out the power plug.
    •   Do not insert fi nger or other objects into the 
    indoor or outdoor unit.
    •  Do not attempt to repair the unit by 
    yourself.
    •  Do not use rechargeable (Ni-Cd) batteries.
    •  Keep the remote control away from infants 
    and small children to prevent them from 
    accidentally swallowing the batteries.
    39
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							Q
    UI
    ETPOW
    ER
    FU
    LIO
    NT
    I
    ME
    R
    PO
    W
    ER
    CANCEL
    O
    FF
    TIMERON
    TIMER
    FA N
    SPEED
    AIR
    SW
    INGA
    UTO
    DRY COOL
    MODE
    TIMER
    ON
    123
    OFF
    CL
    OCK RE
    SET
    SE
    T
    CANCEL
    TEMP
    PO
    WE
    RFULFA
    NSPEED
    AIR SWING
    OFF/ON
    QUIET
    QUIETPOWERFULIONSUPERALLERU-BUSTERTIMER POWER
    Air intake
    Airflow direction louver
    Ionizer Air filterFront panelIIndoor Unitndoor Unit
    OutdoorOutdoor Unit Unit
    Air inlet (rear)
    Air outlet
    LCD display
    Off/On
    Fan speed selection
    Clock setting
    Memory resetTemperature setting Powerful operationOperation mode
    Quiet operation
    Timer settingIon operation
    Airflow direction 
    adjustment
    Remote ControlRemote Control
    IndicatorSupersonic air 
    purifying device
    Auto OFF/ON 
    button
    Receiver
    Transmitter Air inlet 
    (side)
    Discharged air
    Do not touch 
    during operation
    Note:  The illustrations in this manual are for explanation purposes only and may differ from the 
    actual unit. It is subjected to change without notice for future improvement.
    PRODUCT OVERVIEW
    Troubleshooting
      Operation delayed for few minutes after restart.
    ➤  This is a normal self protection control.
      Sound like water fl owing during operation.
    ➤  Caused by refrigerant fl ow inside.
      Mist emerges from indoor unit.
    ➤  Condensation effect due to cooling process.
      Noisy during operations.
    ➤  Installation work could be slanted or front panel didn’t close properly.
      Remote control/display does not work.
    ➤  Check whether batteries are correctly inserted or need replacement.
      The unit cannot operate.
    ➤  Check either circuit breaker is tripped, power plug is inserted correctly or 
    timer is used correctly.
      Outdoor unit emits water/steam.
    ➤  Condensation or evaporation happens at piping surface.
    OP
    E
    N
    •  Make sure it is not obstructed.
    •  Maximum distances: 10m.
    •  Certain fluorescent lights may 
    interfere with signal transmission. 
    Consult your dealer.
    Remote Control Preparation
     About
    Remote Control Signal •  Timer operation will be based on 
    current time set.
    •  The batteries can be used for 
    approximately 1 year.
    •  The batteries must be 
    recycled or disposed of 
    properly. 1.  Pull out
    2. Insert batteries
      (AAA or R03)
    3. Press CLOCK button
    4. Set 
    current 
    time
    5. Press again to confi rm
    •  To operate the unit if the 
    remote control is misplaced or 
    malfunctioning.
    ActionOperation 
    mode
    Press once Automatic 
    Operation
    Press until “beep” 
    sound Cooling 
    Operation
    •  To OFF, press again the Auto OFF/
    ON button.
    •  To switch the remote control signal 
    receiving sound off or on.
    1. Press until “beep” sound and 
    release. 
    2. Press again until “beep-beep” 
    sound and release. 
    3. Press to switch the sound off or 
    on.
      (Long “beep” - OFF; short “beep” 
    - ON)
    Auto OFF/ON Button
    40
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						