    							3.3. CS-W12DKR CU-W12DKR
    UnitCS-W12DKRCU-W12DKR
    Cooling CapacitykW (kcal/h)3.60 (3,100) - 3.60 (3,100)
    BTU/h12,300 - 12,300
    Heating CapacitykW (kcal/h)3.90 (3,350) - 3.90 (3,350)
    BTU/h13,300 - 13,300
    Moisture Removall/h (Pint/h)2.1 (4.4)
    PhaseøSingle
    Power SourceVoltageV230 - 240
    CycleHz50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeLom3/min (cfm)Cooling; 6.7 (236) - 6.7 (236)—
    Heating; 7.1 (251) - 7.1 (251)
    Mem3/min (cfm)Cooling; 8.3 (294) - 8.3 (294)—
    Heating; 8.3 (294) - 8.3 (294)
    Him3/min (cfm)Cooling; 9.5 (340) - 9.5 (340)Cooling; 33.0 (1,160) - 33.5 (1,180)
    Heating; 9.7 (340) - 9.7 (340)
    SHim3/min (cfm)Cooling; 9.7 (343) - 9.7 (343)—
    Heating; 9.7 (343) - 9.7 (343)
    dB (A)Cooling; High 39 - 39, Low 29 - 29Cooling; High 49 - 50
    Heating; High 40 - 40, Low 29 - 29Heating; High 49 - 50
    Noise Level
    Power level (dB)Cooling; High 52 - 52Cooling; High 64 - 65
    Heating; High 53 - 53Heating; High 65 - 66
    Electrical DataInputkWCooling; 1.12 - 1.15
    Heating; 1.08 - 1.11
    Running CurrentACooling; 5.1 - 5.2
    Heating; 4.9 - 5.0
    EERW/W (BTU/hW)Cooling; 3.21 - 3.13 (11.0 - 10.7)
    COPW/W (BTU//hW)Heating; 3.61 - 3.51 (12.3 - 12.0)
    Starting CurrentA22.0
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 1/2”
    L ; Half Union 1/4”G ; 3-way valve 1/2”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 1/2”
    L ; (liquid side) 1/4”G ; (gas side) 1/2”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power Cord Length
    Number of core-wirem1.9
    3 (1.5 mm2)—
    —
    11
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							UnitCS-W12DKRCU-W12DKR
    DimensionsHeightinch (mm)11 - 1/32 (280)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)7 - 7/32 (183)11 - 3/8 (289)
    Net Weightlb (kg)20 (9.0)77 (35)
    CompressorDescription—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—900
    Air CirculationDescriptionCross-flow FanPropeller Fan
    MaterialASG20k1PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW4773
    RatedOutputW1533
    Fan SpeedLowrpmCooling; 900 - 900—
    Heating; 960 - 960
    MediumrpmCooling; 1,120 - 1,120—
    Heating; 1,120 - 1,120
    HighrpmCooling; 1,280 - 1,280845 - 860
    Heating; 1,310 - 1,310
    SuperHighrpmCooling; 1,310 - 1,310—
    Heating; 1,310 - 1,310
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×152×24
    FPI2117
    Size (W×H×L)mm610×315×25.4718.4
    689.9×504×36.4
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FV50S (350)
    Refrigerant (R-410A)g (oz)—1,090 (38.5)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 1,175, Heating; 525
    Flow Ratel/min—Cooling; 4.7, Heating; 8.6
    Inner Diametermm—Cooling; 2.6, Heating; 2.6
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—25 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 440VAC2.0 µF, 440VAC
     • 
    Specifica tions are subject to change without notice for further improvement.
    12
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							4 Dimensions
    4.1. Indoor Unit & Remote Control
    4.1.1. CS-W7DKR CS-W9DKR CS-W12DKR
    13
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							4.2. Outdoor Unit
    4.2.1. CU-W7DKR CU-W9DKR
    4.2.2. CU-W12DKR
    14
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							5 Refrigeration Cycle Diagram
    15
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							6 Block Diagram
    16
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							17
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							7 Wiring Diagram
    18
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							19
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						
    							8 Operation Details
    8.1. Heating Operation
     • Heating operation can be set using remote control.
     • This operation is applied to warm the room temperature reaches the setting temperature set on the remote control.
     • The remote control setting temperature, which takes the reading of intake air temperature sensor, can be adjusted from 16°C
    to 30°C.
     • During heating operation, the compressor will stop running and restart as shown in below figure.
    8.1.1. Heating Operation Time Diagram
    20
    CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR 
    						