Panasonic Cs W7dkr Cs W9dkr Cs W7dkr Series Repair Manual
Here you can view all the pages of manual Panasonic Cs W7dkr Cs W9dkr Cs W7dkr Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 41
Operation Details Auto, Heat, Cool, DryAuto, Heat, Cool, Dr y • Enables you to enjoy the cooling effect at your preferred setting temperature. • The range of temperature can be selected from 16°C ~ 30°C. • Enables you to set the desired temperature at low fan speed which provides you with the dehumidifying surroundings. • The range of temperature can be selected from 16°C ~ 30°C. AUTO - Automatic Operation COOL - Cooling Operation DRY - Soft Dr y Operation HOW TO OPERATE Supersonic air...
Page 42
Operations Details • To provide fresh air effect by producing negative ions. • To achieve setting temperature quickly. It will operate for 15 minutes and return to the previous setting. ION POWERFULPowerful, Powerful, Quiet, Quiet, Ion, Fan Speed, Ion, Fan Speed, Air SwingAir Swing • To provide you with the various fan speed selections. • There are 3 levels of fan speed in addition to automatic fan speed. • Automatic fan speed: The speed of the indoor fan is automatically adjusted...
Page 43
Press CLOCK more than 10 seconds to change the time format from 24 hours to AM/PM format. For your convenience, you could set the air conditioner to operate automatically by using both ON and OFF timer. Hint Troubleshooting TIMER indicator always on. ➤ Timer is activated and the setting will repeat itself daily. POWER indicator is blinking 30 minutes before ON timer is activated.➤ The unit is determining the operation mode by sensing the room temperature. This happens when it has been set...
Page 44
CARE & CLEANING • Wipe the unit gently with a soft, dry cloth. • It is recommended to clean the air fi lters once every 2 weeks. • Purchase the replacement fi lter if it is damaged. Part no.: CWD001144 INDOOR UNIT AIR FILTER • It is recommended to clean the fi lter every 6 months. • Replace the fi lter every 3 years or purchase the replacement fi lter if it is damaged. Part no.: CZ-SA13P SUPER ALLERU-BUSTER Clean the fi lter regularly as dirty fi lters will cause unpurifi ed air, low cooling...
Page 45
10 Installation Instructions Required tools for Installation Works 1.Philips screw driver5.Spanner9.Gas leak detector13.Multimeter 2.Level gauge6.Pipe cutter10.Measuring tape14.Torque wrench 18 N.m (1.8 kgf.m) 42 N.m (4.2 kgf.m) 55 N.m (5.5 kgf.m) 3.Electric drill, hole core drill (ø70 mm)7.Reamer11.Thermometer15.Vacuum pump 4.Hexagonal wrench (4 mm)8.Knife12.Megameter16.Gauge manifold 10.1. Safety Precautions • Read the followin g“SAFET Y PRECA UTIONS”carefully before installation. • Electrical work...
Page 46
CAUTION 1.The equipment must be earthed. It may cause electrical shock if grounding is not perfect. 2.Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fire. 3.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture. ATTENTION 1.Selection of the installation location. Select a installation location which is rigid and...
Page 47
Attached access ories Applica ble piping kit CZ-3F5, 7BP (V7DK, V9DK,W7DK, W9DK) CZ-4F5, 7, 10BP (V12DK , W12DK) Select the best location INDOOR UNIT • There should not be any heat source or steam near the unit. • There should not be any obstacles blocking the air circulation. • A place where air circulation in the room is good. • A place where drainage can be easily done. • A place where noise prevention is taken into conside ration. • Do not install the unit near the door way. • Ensure the...
Page 48
10.2.1. SELECT THE BEST LOCATION (Refer to “Select the best location” section) 10.2.2. HOW TO FIX INSTALLATION PLATE The mounting wall is strong and solid enough to prevent itfrom the vibration. The centre of installation plate should be at more than 450 mm at right and left of the wall. The distance from installation plate edge toceiling should more than 67 mm. From installation plate left edge to unit’s left side is 74 mm. From installation plate right edge to unit’s right is 94 mm. : : :For left side...
Page 49
3. For the embedded piping (This can be used for left rear piping & left bottom piping also.) 49 CS-W7DKR CU-W7DKR / CS-W9DKR CU-W9DKR / CS-W12DKR CU- W12DKR
Page 50
10.2.5. CONNECT THECABLE TO THE INDOOR UNIT 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connec ting cable between indoor unit and outdoor unit shall be approved polychl oroprene sheathed 3 (V7DK, V9DK, V12DK ) or 5(W7DK, W9DK, W12DK)×1.5 mm 2 flexible cord, type designa tion 245 IEC 57 or heavier cord. • Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively. • Earth lead wire shall be longer than...