Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual
Have a look at the manual Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SCHEMATIC DIAGRAM 2/3 Q03 4.7k 10k e bc T01 5 8 13 2 A52D0022GB75IC01 P72 P73 P74 P75 P64 P65 P66 P67 P40/AD0 P41/AD1 P42/AD2 P43/AD3 P44/AD4 P45/AD5 P46/AD6 P47/AD7 P11/AN1 P12/AN2 P13/AN3 P14/AN4 P15/AN5 P16/AN6 P17/AN7AVss VDD1 P25 P24 P23 P22/SCK P21/S0 P20/S1P36 P51/A9P50/A8 P53/A11P52/A10 P54/A12 P56/A14P55/A13 P57/A15 VDD0Vss0 P31P30 P32 P34 P35P3346 41 42 4344 45 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 40 39 38 37 36 35 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 1615 1413 12119 87 65 432 1 P02/INTP2 P01/INTP1 P00/INTP0P70 P71 P03/INTP3 Vss1 X1 X2 IC XT1 XT2 Reset AVref P10 /ANO AVd0 R10 10k 150kR32 X014.096MHz (47pF X 2) C10 R56 R31 10k R09 JX2 TESTR02 1k R01 10k C06 Q04 c eb R44 1k1.0kR41 GENERATOR POWER CLOCKC16 10k R37C15JX4R38 JX1 Q01 4.7k 10k e bc BZ1BZ 1k R55 51k R34 DISPLAY GROUNDPOWER RESET PIPE TEMP DEICE DETECTION INTAKE AIR TEMP OSC REMOTE-CONTROL POWER CLOCK INPUTDRIVE SIGNALFAN SPEED BUZZER COMMAND INPUT SIGNALDRIVEMOTOR STEPPING RY-PWR DRIVE SIGNAL AUTO OPERATION TEST RUN REMOTE CONTROL SOUND TIMER SHORTEN RY-HOT DRIVE SIGNAL REMOTE CONTROL NO. SHORT SHORT OPEN SHORTSHORT OPEN OPEN OPEN 1 0 3 2JX3 JX4 RX1 10K10K SSR01 34 10 Q02 4.7k 10k e bc SSR02 6.2kR64 6.2kR63 c e b Q07 CN-ION4 321C31 C32D01 AUTO RESTARTERROR FEEDBACK IONIZER ON/OFF CONTROL 81 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
SCHEMATIC DIAGRAM 3/3 IC03 G I16VC115V 12VI G IC04 C1735V (NHG) DB01 C1425V 1k R3650/60Hz AC 220-240V MOTORFAN CN-FM5 4 3 1 CN-FB1(PH-3) RY-PWR 250V 2AAC (WHT) 511U ZNR01 REGULATOR REGULATOR +~ ~ C12400VC-FM C03 SSR01 511U ZNR03 L01 C19 510 R48 39k/2WR47 39k/2WR57 820 R03 4.7kR293.9kR26 3 41 2 PC01 C07 10k R40 JX3 24k R42 RX1 R43 C18c eb R50 100k R49 1kR51 10k c eb6.2kR54 10k R53 6.2kR52 ZD1 7.5EL1 D13 D14 RB501V-40 Q05Q06 50VC21 GENERATION RESET SIGNAL GENERATION RESET SIGNAL 2 FUSE CT01 OO 10k R35 3 21 16V C09+ SSR02 RY-HOTCR02 CR01 FM(BLU) HOT(RED) EH-4PCH1 VIN GND ERR 4 321 F1 C2 C1Q1 Q2Q4 Q5 R2R16 c eb 4.7k 10k e bcC3 R4 R3 R3 D2 Z01D1 c eb C3 D1D3 R14 R13 R9 R15 R10R102-5.7kV R101HV CN2 R12 C5 D6 D5 C10 C9 C6 Z02 c eb R6 T01D101 D102 C* C7 GNDCN3 1 2 3 4 1 2 3 4 COIL REVERSING VALVE ELECTROLYTIC CAPACITOR MAGNETIC RELAY B BL/B BL BL FAN MOTOR CAPACITORCAPACITOR OVER LOAD PROTECTOR COMPRESSOR TRS BLBL 3 314 4 1 28 28 67 567BL/B BL GRY GRY GRY Y Y ROBR BB B B R B B RMAGNETIC RELAY A 82 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
83 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
How to use electronic circuit diagram TIMER TABLE Test Mode NameTime(Whentest pointRemarks Short-circuited) Real Timer1hr.1 min. 10 min.10 sec. 1 min.1 sec. Time Delay Safety Control2 min. 58 sec.0 sec. Forced Operation60 sec.0 sec. Time Save Control7 min.4.2 sec. Anti-Freezing4 min.0 sec. Auto Mode Judgement25 sec.0 sec. Soft DryOFF6 min.36 sec. ON10 min.60 sec.Soft Dry: 10 min. operation Deodorizing Control Cooling40 sec.4 sec. 70 sec.7 sec. 20 sec.2 sec. 180 sec.18 sec. Soft Dry40 sec.4 sec. 360 sec.36 sec. Comp. Reverse Rotation Detection5 min.30 sec.Comp. ON 5 min. and above 2 min.0 sec. Comp./ Fan Motor Delay Timer1.6 sec.0 sec. Powerful Mode Operation15 min.15 sec. Random Auto Restart Control0 ~ 62 sec.0 ~ 6.2 sec. TRS Recovery Detection12 min.72 sec. 6 min.36 sec. 3 min.18 sec. 1 min.6 sec. Time Save Control (Heating)30 min.3 sec. 4 Way Valve Control (Delay)5 min.30 sec. Deice Operation Occurs60 min.6 sec.60 min. after previous deice 4 min.24 sec.Continuously 4 min. Comp. ON 50 sec.0 sec.TRS ON continuously for 50 sec. check Overload Deice Timer1 min.6 sec.Comp. ON continuously for 1 min. check Deice End12 min.72 sec.Max. Operation time 30 sec.3 sec.30 sec. Comp. OFF after deice 10 sec.1 sec.4-Way Valve ON 10 sec. later after deice Deice Operation (Extend)60 sec.0 sec. 120 sec.0 sec. 180 sec.0 sec. Hotstart Finish30 sec.0 sec. Ion OFF Timer10 min.10 sec. 84 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
19.1. REMOTE CONTROL 85 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
19.2. PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD TOP VIEW 86 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5
19.3. PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD BOTTOM VIEW 87 CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 [MAICO] Printed in Malaysia