Page 1
1 Features 2 2 Functions 3 3 Product Specifications 6 4 Dimensions 12 5 Refrigeration Cycle Diagram 14 6 Block Diagram 15 7 Wiring Diagram 16 8 Operation Details 17 9 Operating Instructions 39 10 Installation Instructions 44 © 2002 Matsushita Industrial Corp. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-W7CKP CU-W7CKP5 CS-W9CKP CU-W9CKP5 CS-W12CKP CU-W12CKP5 11 Installation and Servicing Air Conditioner Using R410A 54 12...
Page 2
• High Efficiency • Compact Design • Comfort Environment − Ionizer control for generate negative ion in discharge air − Air filter with function to reduce dust and smoke − W ider range of horizontal discharge air • Auto Restart − Random auto restart after power failure for safety restart operation • Removable and Washa ble Front Panel • Remote Control Self-illuminating Button • Catechin Air Purifying Filter − Trap dust, tobacco smoke and tiny particles − Prevent the growth of bacteria and...
Page 3
2 Functions Remote Control Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP. Operation Mode Selection •AUTOAutomatic Operation Mode • HEATHeating Operation Mode • COOLCooling Operation Mode • DRYSoft Dry Operation Mode MODE TIMETime / Timer Setting • Hours and minutes setting. Clock Setting • Current time setting. Indoor Fan Speed SelectionFAN SPEED •FAN Low Fan Speed • FAN Medium Fan Speed • FAN High Fan Speed • AUTOAutomatic Fan SpeedFAN Vertical Airflow Direction Control • 24-hour, OFF / ON...
Page 4
Indoor Unit Random Auto Restart Control •Operation is restarted randomly after power failure at previous setting mode. Anti-Freezing Control •Anti-Freezing control for indoor heat exchanger. (Cooling and Soft Dry) Ionizer Control •Ionizer control for generate negative ion in discharge air. Indoor Fan Speed Control •High, Medium and Low. •Automatic Fan Speed Mode –Heating : Fan speed varies from Me → SSLo in accordance with indoor heat exchanger. –Cooling : Fan rotates at Hi, Me and SLo speed. Deodorizing...
Page 5
Outdoor Unit •To protect compressor from reverse rotation when there is a instantaneous power failure. 60 Secs. Forced Operation Control •Once the compressor is activated, it does not stop within the first 60 secs. However, it stops immediately with remote control stop signal. Overload Protector •2-Stage OLP to protect the compressor. Overload Protector will trip when – Temperature of compressor increases to 120°C. – High temperature or high current flows to compressor. (Refer circuit diagram for OLP...
Page 6
3 Product Specifications UnitCS-W7CKPCU-W7CKP5 Cooling CapacitykW (kcal/h)2.38 (2,050) BTU/h8,120 Heating CapacitykW (kcal/h)2.45 (2,110) BTU/h8,350 Moisture Removall/h (Pint/h)1.5 (3.2) PhaseSingle Power SourceV230 Cycle50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.4 (230)— Heating; 7.0 (250) Indoor Air (Me)m3/min (cfm)Cooling; 7.6 (270)— Heating; 7.7 (270) Indoor Air (Hi)m3/min (cfm)Cooling; 8.5 (300)Cooling; 34.5 (1,220) Heating; 9.9 (350) Indoor Air...
Page 7
UnitCS-W7CKPCU-W7CKP5 DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540) Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780) Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289) Net Weightlb (kg)20 (9.0)71 (32) CompressorType—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—670 Air CirculationTypeCross-flow FanPropeller Fan MaterialAS + Glass Fiber 20%PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW49.263.0 RatedOutputW1529 Fan SpeedLowrpmCooling; 780— Heating; 840...
Page 8
UnitCS-W9CKPCU-W9CKP5 Cooling CapacitykW (kcal/h)2.90 (2,490) BTU/h9,890 Heating CapacitykW (kcal/h)3.14 (2,700) BTU/h10,700 Moisture Removall/h (Pint/h)1.7 (3.6) PhaseSingle Power SourceV230 Cycle50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.8 (240)— Heating; 7.0 (250) Indoor Air (Me)m3/min (cfm)Cooling; 8.3 (290)— Heating; 8.0 (280) Indoor Air (Hi)m3/min (cfm)Cooling; 9.9 (350)Cooling; 34.5 (1,220) Heating; 10.2 (360) Indoor Air (SHi)m3/min...
Page 9
UnitCS-W9CKPCU-W9CKP5 Net Weightlb (kg)20 (9.0)73 (33) CompressorType—Rotary (1 cylinder) rolling pistontype MotorType—Induction (2-poles) RatedOutputW—780 Air CirculationTypeCross-flow FanPropeller Fan MaterialAS + Glass Fiber 20%PP Resin MotorTypeInduction (4-poles)Induction (6-poles) InputW49.263.0 RatedOutputW1529 Fan SpeedLowrpmCooling; 780— Heating; 840 MediumrpmCooling; 960— Heating; 960 HighrpmCooling; 1,140820 Heating; 1,230 SuperHighrpmCooling; 1,230— Heating; 1,230 Heat...
Page 10
UnitCS-W12CKPCU-W12CKP5 Cooling CapacitykW (kcal/h)3.74 (3,220) BTU/h12,800 Heating CapacitykW (kcal/h)4.09 (3,520) BTU/h14,000 Moisture Removall/h (Pint/h)2.2 (4.6) PhaseSingle Power SourceV230 Cycle50 Airflow MethodOUTLET INTAKE SIDEVIEWTOP VIEW Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 7.3 (260)— Heating; 7.8 (270) Indoor Air (Me)m3/min (cfm)Cooling; 9.1 (320)— Heating; 9.1 (320) Indoor Air (Hi)m3/min (cfm)Cooling; 10.2 (360)Cooling; 33.0 (1,160) Heating; 10.6 (370) Indoor Air (SHi)m3/min...