Home > Panasonic > Air Conditioner > Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual

Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual

Here you can view all the pages of manual Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 1

 1 Features 2
 2 Functions 
3
 3 Product Specifications 
6
 4 Dimensions 
12
 5 Refrigeration Cycle Diagram 
14
 6 Block Diagram 
15
 7 Wiring Diagram 
16
 8 Operation Details 
17
 9 Operating Instructions 
39
 10  Installation Instructions  
44
© 2002 Matsushita Industrial Corp. Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
CS-W7CKP CU-W7CKP5
CS-W9CKP CU-W9CKP5
CS-W12CKP CU-W12CKP5
 11  Installation and Servicing Air Conditioner Using R410A 54
 12...

Page 2

 • High Efficiency
 • Compact Design
 • Comfort Environment
 − Ionizer control for generate negative ion in discharge air
 − Air filter with function to reduce dust and smoke
 − W ider range of horizontal discharge air
 • Auto Restart
 − Random auto restart after power failure for safety restart
operation
 • Removable and Washa ble Front Panel
 • Remote Control Self-illuminating Button
 • Catechin Air Purifying Filter
 − Trap dust, tobacco smoke and tiny particles
 − Prevent the growth of bacteria and...

Page 3

2 Functions
Remote Control
Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP.
Operation Mode Selection
•AUTOAutomatic Operation Mode
•
HEATHeating Operation Mode
•
COOLCooling Operation Mode
•
DRYSoft Dry Operation Mode
MODE
TIMETime / Timer Setting
• Hours and minutes setting.
Clock Setting
• Current time setting.
Indoor Fan Speed SelectionFAN SPEED
•FAN Low Fan Speed
•
FAN Medium Fan Speed
•
FAN High Fan Speed
•
AUTOAutomatic Fan SpeedFAN
Vertical Airflow Direction Control
• 24-hour, OFF / ON...

Page 4

Indoor Unit
Random Auto Restart Control
•Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
•Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
•Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
•High, Medium and Low.
•Automatic Fan Speed Mode
–Heating : Fan speed varies from Me →
SSLo in accordance with
indoor heat exchanger.
–Cooling : Fan rotates at Hi, Me and SLo
speed. Deodorizing...

Page 5

Outdoor Unit
•To protect compressor from reverse
rotation when there is a instantaneous
power failure.
60 Secs. Forced Operation Control
•Once the compressor is activated, it
does not stop within the first 60 secs.
However, it stops immediately with
remote control stop signal.
Overload Protector
•2-Stage OLP to protect the compressor.
Overload Protector will trip when
– Temperature of compressor increases
to 120°C.
– High temperature or high current flows
to compressor.
(Refer circuit diagram for OLP...

Page 6

3 Product Specifications
UnitCS-W7CKPCU-W7CKP5
Cooling CapacitykW (kcal/h)2.38 (2,050)
BTU/h8,120
Heating CapacitykW (kcal/h)2.45 (2,110)
BTU/h8,350
Moisture Removall/h (Pint/h)1.5 (3.2)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.4 (230)—
Heating; 7.0 (250)
Indoor Air (Me)m3/min (cfm)Cooling; 7.6 (270)—
Heating; 7.7 (270)
Indoor Air (Hi)m3/min (cfm)Cooling; 8.5 (300)Cooling; 34.5 (1,220)
Heating; 9.9 (350)
Indoor Air...

Page 7

UnitCS-W7CKPCU-W7CKP5
DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
Net Weightlb (kg)20 (9.0)71 (32)
CompressorType—Rotary (1 cylinder)
rolling pistontype
MotorType—Induction (2-poles)
RatedOutputW—670
Air CirculationTypeCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW49.263.0
RatedOutputW1529
Fan SpeedLowrpmCooling; 780—
Heating; 840...

Page 8

UnitCS-W9CKPCU-W9CKP5
Cooling CapacitykW (kcal/h)2.90 (2,490)
BTU/h9,890
Heating CapacitykW (kcal/h)3.14 (2,700)
BTU/h10,700
Moisture Removall/h (Pint/h)1.7 (3.6)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.8 (240)—
Heating; 7.0 (250)
Indoor Air (Me)m3/min (cfm)Cooling; 8.3 (290)—
Heating; 8.0 (280)
Indoor Air (Hi)m3/min (cfm)Cooling; 9.9 (350)Cooling; 34.5 (1,220)
Heating; 10.2 (360)
Indoor Air (SHi)m3/min...

Page 9

UnitCS-W9CKPCU-W9CKP5
Net Weightlb (kg)20 (9.0)73 (33)
CompressorType—Rotary (1 cylinder)
rolling pistontype
MotorType—Induction (2-poles)
RatedOutputW—780
Air CirculationTypeCross-flow FanPropeller Fan
MaterialAS + Glass Fiber 20%PP Resin
MotorTypeInduction (4-poles)Induction (6-poles)
InputW49.263.0
RatedOutputW1529
Fan SpeedLowrpmCooling; 780—
Heating; 840
MediumrpmCooling; 960—
Heating; 960
HighrpmCooling; 1,140820
Heating; 1,230
SuperHighrpmCooling; 1,230—
Heating; 1,230
Heat...

Page 10

UnitCS-W12CKPCU-W12CKP5
Cooling CapacitykW (kcal/h)3.74 (3,220)
BTU/h12,800
Heating CapacitykW (kcal/h)4.09 (3,520)
BTU/h14,000
Moisture Removall/h (Pint/h)2.2 (4.6)
PhaseSingle
Power SourceV230
Cycle50
Airflow MethodOUTLET
INTAKE
SIDEVIEWTOP VIEW
Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 7.3 (260)—
Heating; 7.8 (270)
Indoor Air (Me)m3/min (cfm)Cooling; 9.1 (320)—
Heating; 9.1 (320)
Indoor Air (Hi)m3/min (cfm)Cooling; 10.2 (360)Cooling; 33.0 (1,160)
Heating; 10.6 (370)
Indoor Air (SHi)m3/min...