    							 1 Features 2
     2 Functions 
    3
     3 Product Specifications 
    6
     4 Dimensions 
    12
     5 Refrigeration Cycle Diagram 
    14
     6 Block Diagram 
    15
     7 Wiring Diagram 
    16
     8 Operation Details 
    17
     9 Operating Instructions 
    39
     10  Installation Instructions  
    44
    © 2002 Matsushita Industrial Corp. Sdn. Bhd.
    (11969-T). All rights reserved. Unauthorized copying
    and distribution is a violation of law.
    CS-W7CKP CU-W7CKP5
    CS-W9CKP CU-W9CKP5
    CS-W12CKP CU-W12CKP5
     11  Installation and Servicing Air Conditioner Using R410A 54
     12  Servicing Information 
    65
     13  Troubleshooting Guide 
    69
     14  Technical Data 
    71
     15  Exploded View 
    76
     16  Replacement Parts List 
    77
     17  Exploded View 
    78
     18  Replacement Parts List 
    79
     19  Electronic Circuit Diagram 
    80
    Room Air Conditioner
    CONTENTS
     Page  Page
    Order No. MAC0210044C2 
    						
    							 • High Efficiency
     • Compact Design
     • Comfort Environment
     − Ionizer control for generate negative ion in discharge air
     − Air filter with function to reduce dust and smoke
     − W ider range of horizontal discharge air
     • Auto Restart
     − Random auto restart after power failure for safety restart
    operation
     • Removable and Washa ble Front Panel
     • Remote Control Self-illuminating Button
     • Catechin Air Purifying Filter
     − Trap dust, tobacco smoke and tiny particles
     − Prevent the growth of bacteria and viruses trapped
     • Triple Deodorizing Filter
     − Absorb odours produced by wall paper, construction
    material and living environment • Quality Improvement
     − Gas leakage protection
     − Prevent compressor reverse cycle
     − 2-stage OLP to protect compressor
     − Noise prevention during soft dry operation.
     − Compressor Protection Control (Cooling & Soft Dry)
     − Overload Protection Control (Heating)
     − Outdoor Fan Control
     − Compressor High Pressure Control
     − Blue Coated Conden ser
     − High resistance to corrosion.
     • Operation Improvement
     − Quiet mode to provide extra quiet operation
     − Powerful mode to reach the desired room temperature
    quickly
     • Long Installation Piping
     − CS/CU-W7CK, CS/CU-W9CK,long piping up to 10
    meter
     − CS/CU-W12CK, long piping up to 15 meter
     • 24-hour Timer Setting
     • Environmental Friendly
     − R410A, which does not contain chlorine , is used as its
    refrigerant, so there is no danger of damage to the
    ozone layer in Stratosphere.
    1 Features
    2
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							2 Functions
    Remote Control
    Operation OFF / ONOFF / ON IRoom Temperature SettingTEMP.
    Operation Mode Selection
    •AUTOAutomatic Operation Mode
    •
    HEATHeating Operation Mode
    •
    COOLCooling Operation Mode
    •
    DRYSoft Dry Operation Mode
    MODE
    TIMETime / Timer Setting
    • Hours and minutes setting.
    Clock Setting
    • Current time setting.
    Indoor Fan Speed SelectionFAN SPEED
    •FAN Low Fan Speed
    •
    FAN Medium Fan Speed
    •
    FAN High Fan Speed
    •
    AUTOAutomatic Fan SpeedFAN
    Vertical Airflow Direction Control
    • 24-hour, OFF / ON Real Timer Setting.
    ON-TIMER
    OFF-TIMER
    Timer Operation Selection
    SET
    CANCEL
    Timer Operation Set / Cancel
    • ON Timer and OFF Timer setting and
    cancellation.
    CLOCK
    AIR SWING
    •AUTOAutomatic Vertical Airflow
    Direction Control
    •
    MANUALVertical Airflow Direction
    Manual Control (5 stages of
    adjustment)
    Powerful Mode Operation OFF/ONPOWERFUL
    Quiet Mode Operation OFF/ONQUIET
    Heating, Cooling, Soft Dry Operation.
    • Temperature Setting (16°C to 30°C)
    Automatic Operation
    •
    Operation with 2°C higher than
    standard temperature.
    • Operation with standard temperature.
    •
    Operation with 2°C lower than
    standard temperature.
    Self illuminating
    button
    Ionizer Operation OFF / ON
    3
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							Indoor Unit
    Random Auto Restart Control
    •Operation is restarted randomly after power
    failure at previous setting mode.
    Anti-Freezing Control
    •Anti-Freezing control for indoor heat
    exchanger. (Cooling and Soft Dry)
    Ionizer Control
    •Ionizer control for generate negative ion in
    discharge air.
    Indoor Fan Speed Control
    •High, Medium and Low.
    •Automatic Fan Speed Mode
    –Heating : Fan speed varies from Me →
    SSLo in accordance with
    indoor heat exchanger.
    –Cooling : Fan rotates at Hi, Me and SLo
    speed. Deodorizing control is
    available.
    –Soft Dry : Fan rotates at Lo- speed.
    Deodorizing control is
    available.
    •Automatic air swing and manual adjusted
    by remote control for vertical airflow.
    •Manually adjusted by hand for horizontal
    airflow.
    Airflow Direction Control
    Automatic Operation Button
    •Press for < 5s to operate Automatic
    operation mode.
    (Used when the remote control cannot be used.)
    •Press continuously for 5s or < 10s  to
    operate Test Run/Pump down. “Beep”
    sound will be heard at the 5th second.
    (Used when test running or servicing.)
    •Press continuously for 10s and above to
    omit or resume the remote control signal
    receiving sound. “Beep, beep” sound will
    be heard at the 10th second.
    AUTO
    OFF / ON
    Operation Indication Lamps (LED)
    •POWER (Green) ......... Lights up in operation,
    blinks in Automatic
    Operation Mode judging.
    •QUIET (Orange) ......... Lights up in Quiet Mode
    Operation.
    •TIMER (Orange) ......... Lights up in Timer
    Setting.
    •POWERFUL (Orange) ... Lights up in Powerful
    Mode Operation.
    • (Green) ............ Lights up in Ionizer
    Mode Operation.
    Operation Mode
    •Heating, Cooling, Soft Dry and Automatic
    Mode.
    Powerful Operation
    •Reaches the desired room temperature
    quickly.
    Time Delay Safety Control
    •Restarting is inhibited for appro. 3 minutes.
    Starting Current Control
    Quiet Operation
    •To provide extra quiet operation.
    7 Minutes Time Save Control
    •Cooling Operation only.
    •Fan motor is delayed for 1.6 seconds when
    compressor starts simultaneously.
    30 Minutes Time Save Control
    •Heating Operation only.
    Hot-Start Control
    •At Heating Operation the indoor fan will
    operate at SLo speed when indoor heat
    exchanger temperature reaches 30°C.
    Anti Cold Draft Control
    •The indoor fan operates at SSLo when the
    indoor heat exchanger temperature is low.
    (During Heating mode thermal off)
    4
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							Outdoor Unit
    •To protect compressor from reverse
    rotation when there is a instantaneous
    power failure.
    60 Secs. Forced Operation Control
    •Once the compressor is activated, it
    does not stop within the first 60 secs.
    However, it stops immediately with
    remote control stop signal.
    Overload Protector
    •2-Stage OLP to protect the compressor.
    Overload Protector will trip when
    – Temperature of compressor increases
    to 120°C.
    – High temperature or high current flows
    to compressor.
    (Refer circuit diagram for OLP
    characteristic)
    Compressor Reverse Rotation
    Protection Control
    Outdoor Fan Operation Control
    •Temperature Fuse.
    4-Way Valve Control
    •When the unit is switched to “OFF”
    during Heating Operation, 4-way valve
    stays at Heating position for 5 minutes.
    Overload Protection Control
    •Outdoor fan stops when indoor heat
    exchanger temperature rises to 51°C
    and above, and restarts when the indoor
    heat exchanger temperature drops to
    49°C and below.
    •Compressor stop when indoor heat
    exchanger temperature reaches 65°C or
    above. (Heating Operation Only)
    Deice Control
    •To prevent frosting at outdoor heat
    exchanger. (Only for Heating Operation)
    •
    Temperature of outdoor heat exchanger
    is sensed by TRS (Thermal Reed Switch).
    TRS OFF temperature 4°C.
    TRS ON temperature -3°C.
    Compressor Protection Control
    •If the outdoor fan motor is not running
    after compressor starts for 50 secs.,
    compressor will stop. (Cooling and Soft
    Dry Operation only).
    5
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							3 Product Specifications
    UnitCS-W7CKPCU-W7CKP5
    Cooling CapacitykW (kcal/h)2.38 (2,050)
    BTU/h8,120
    Heating CapacitykW (kcal/h)2.45 (2,110)
    BTU/h8,350
    Moisture Removall/h (Pint/h)1.5 (3.2)
    PhaseSingle
    Power SourceV230
    Cycle50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.4 (230)—
    Heating; 7.0 (250)
    Indoor Air (Me)m3/min (cfm)Cooling; 7.6 (270)—
    Heating; 7.7 (270)
    Indoor Air (Hi)m3/min (cfm)Cooling; 8.5 (300)Cooling; 34.5 (1,220)
    Heating; 9.9 (350)
    Indoor Air (SHi)m3/min (cfm)Cooling; 9.9 (350)—
    Heating; 9.9 (350)
    Noise LeveldB (A)Cooling; High 34, Low 26Cooling; High 46
    Heating; High 36, Low 26Heating; High 48
    Power level dBCooling; High 47Cooling; High 61
    Heating; High 49Heating; High 63
    Electrical DataInputWCooling; 660
    Heating; 595
    Running CurrentACooling; 3.0
    Heating; 2.7
    EERW/W (BTU/hW)Cooling; 3.61 (12.3)
    COPW/W (BTU/hW)Heating; 4.12 (14.0)
    Starting CurrentA12.5
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 3/8”
    L ; Half Union 1/4”G ; 3-way valve 3/8”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 3/8”
    L ; (liquid side) 1/4”G ; (gas side) 3/8”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power Cord Length
    Number of core-wirem1.9
    3 (1.0 mm2)—
    —
    6
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							UnitCS-W7CKPCU-W7CKP5
    DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
    Net Weightlb (kg)20 (9.0)71 (32)
    CompressorType—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—670
    Air CirculationTypeCross-flow FanPropeller Fan
    MaterialAS + Glass Fiber 20%PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW49.263.0
    RatedOutputW1529
    Fan SpeedLowrpmCooling; 780—
    Heating; 840
    MediumrpmCooling; 920—
    Heating; 920
    HighrpmCooling; 1,030820
    Heating; 1,190
    SuperHighrpmCooling; 1,190—
    Heating; 1,190
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×151×20
    FPI2117
    Size (W × H × L)mm610 × 315 × 25.4841 × 508 × 22
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FVC68D (330)
    Refrigerant (R-410A)g (oz)—970 (34.2)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 970, Heating; 610
    Flow Ratel/min—Cooling; 5.0, Heating; 6.5
    Inner Diametermm—Cooling; 1.2, Heating; 1.2
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—25 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
     • 
    Specifica tions are subject to change without notice for further improvement.
    7
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							UnitCS-W9CKPCU-W9CKP5
    Cooling CapacitykW (kcal/h)2.90 (2,490)
    BTU/h9,890
    Heating CapacitykW (kcal/h)3.14 (2,700)
    BTU/h10,700
    Moisture Removall/h (Pint/h)1.7 (3.6)
    PhaseSingle
    Power SourceV230
    Cycle50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 6.8 (240)—
    Heating; 7.0 (250)
    Indoor Air (Me)m3/min (cfm)Cooling; 8.3 (290)—
    Heating; 8.0 (280)
    Indoor Air (Hi)m3/min (cfm)Cooling; 9.9 (350)Cooling; 34.5 (1,220)
    Heating; 10.2 (360)
    Indoor Air (SHi)m3/min (cfm)Cooling; 10.2 (360)—
    Heating; 10.2 (360)
    dB (A)Cooling; High 36, Low 26Cooling; High 48
    Heating; High 39, Low 26Heating; High 49
    Noise Level
    Power level (dB)Cooling; High 49Cooling; High 63
    Heating; High 52Heating; High 64
    Electrical DataInputWCooling; 850
    Heating; 780
    Running CurrentACooling; 3.7
    Heating; 3.5
    EERW/W (BTU/hW)Cooling; 3.41 (11.6)
    COPW/W (BTU/hW)Heating; 4.03 (13.7)
    Starting CurrentA15.9
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 3/8”
    L ; Half Union 1/4”G ; 3-way valve 3/8”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 3/8”
    L ; (liquid side) 1/4”G ; (gas side) 3/8”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power Cord Length
    Number of core-wirem1.9
    3 (1.0 mm2)—
    —
    DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
    8
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							UnitCS-W9CKPCU-W9CKP5
    Net Weightlb (kg)20 (9.0)73 (33)
    CompressorType—Rotary (1 cylinder)
    rolling pistontype
    MotorType—Induction (2-poles)
    RatedOutputW—780
    Air CirculationTypeCross-flow FanPropeller Fan
    MaterialAS + Glass Fiber 20%PP Resin
    MotorTypeInduction (4-poles)Induction (6-poles)
    InputW49.263.0
    RatedOutputW1529
    Fan SpeedLowrpmCooling; 780—
    Heating; 840
    MediumrpmCooling; 960—
    Heating; 960
    HighrpmCooling; 1,140820
    Heating; 1,230
    SuperHighrpmCooling; 1,230—
    Heating; 1,230
    Heat ExchangerDescriptionEvaporatorCondenser
    Tube materialCopperCopper
    Fin materialAluminium (Pre Coat)Aluminium (Blue Coat)
    Fin TypeSlit FinCorrugate Fin
    Row / Stage(Plate fin configuration, forced draft)
    2×151×20
    FPI2117
    Size (W×H×L)mm610×315×25.4841×508×22
    Refrigerant Control Device—Capillary Tube
    Refrigeration Oil(cm3)—FVC68D (330)
    Refrigerant (R-410A)g (oz)—940 (33.2)
    ThermostatElectronic Control—
    Protection Device—Overload Protector
    Capillary TubeLengthmm—Cooling; 970, Heating; 720
    Flow Ratel/min—Cooling; 5.0, Heating; 7.5
    Inner Diametermm—Cooling; 1.2, Heating; 1.3
    Air FilterMaterial
    StyleP.P.
    Honeycomb—
    Capacity ControlCapillary Tube
    Compressor CapacitorµF, VAC—30 µF, 370VAC
    Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC
     • 
    Specifica tions are subject to change without notice for further improvement.
    9
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							UnitCS-W12CKPCU-W12CKP5
    Cooling CapacitykW (kcal/h)3.74 (3,220)
    BTU/h12,800
    Heating CapacitykW (kcal/h)4.09 (3,520)
    BTU/h14,000
    Moisture Removall/h (Pint/h)2.2 (4.6)
    PhaseSingle
    Power SourceV230
    Cycle50
    Airflow MethodOUTLET
    INTAKE
    SIDEVIEWTOP VIEW
    Air VolumeIndoor Air (Lo)m3/min (cfm)Cooling; 7.3 (260)—
    Heating; 7.8 (270)
    Indoor Air (Me)m3/min (cfm)Cooling; 9.1 (320)—
    Heating; 9.1 (320)
    Indoor Air (Hi)m3/min (cfm)Cooling; 10.2 (360)Cooling; 33.0 (1,160)
    Heating; 10.6 (370)
    Indoor Air (SHi)m3/min (cfm)Cooling; 10.6 (370)—
    Heating; 10.6 (370)
    dB (A)Cooling; High 39, Low 29Cooling; High 49
    Heating; High 40, Low 29Heating; High 49
    Noise Level
    Power level (dB)Cooling; High 52Cooling; High 64
    Heating; High 53Heating; High 65
    Electrical DataInputkWCooling; 1.10
    Heating; 1.07
    Running CurrentACooling; 4.9
    Heating; 4.8
    EERW/W (BTU/hW)Cooling; 3.40 (11.6)
    COPW/W (BTU//hW)Heating; 3.82 (13.1)
    Starting CurrentA17.8
    Piping Connection Port
    (Flare piping)inch
    inchG ; Half Union 1/2”
    L ; Half Union 1/4”G ; 3-way valve 1/2”
    L ; 2-way valve 1/4”
    Pipe Size
    (Flare piping)inch
    inchG ; (gas side) 1/2”
    L ; (liquid side) 1/4”G ; (gas side) 1/2”
    L ; (liquid side) 1/4”
    Drain
    HoseInner diametermm12—
    Lengthmm650—
    Power Cord Length
    Number of core-wirem1.9
    3 (1.0 mm2)—
    —
    DimensionsHeightinch (mm)10 - 13/16 (275)21 - 1/4 (540)
    Widthinch (mm)31 - 15/32 (799)30 - 23/32 (780)
    Depthinch (mm)8 - 9/32 (210)11 - 3/8 (289)
    10
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						