    							31
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							 1. Vertical Airflow Direction
     • The louver swings up and down as shown above.
     • The louver does not swing when the Indoor Fan stops
    during operation at the upper limit.
    Heating Mode
     • W hen the intake air temp. reaches 38°C, the louver is
    changed from upper to lower limit.When theintake air
    temp falls to 35°C, the louver is changed from lower to
    upper limit.
     2. Horizontal Airflow Direction
     • The louver can be selected between 14°-36°(as
    shown above) when pressing Manua l Airflow Direction
    Selection Button.
     • The louver can be selected between 0°-61°(as shown
    above) when pressing Manua l Airflow Direction
    Selection Button.
    8.9. Airflow Direction Control
    Cooling, Ion and Soft Dry Mode
     • The left and right airflow direction louvers can be adjusted manually.
    32
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							8.10. Powerful Mode Operation
    Purpose of this operation is to be obtain the setting temperature quickly.
     1. Cooling and Soft Dry Mode
     • W hen the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
    temperature (Lower temperature: 16°C). This operation automatically will be running under SHi Fan speed (cooling), Lo-
    Fan Speed (Soft Dry).
     • Vertical Airflow Direction:-
    In“Manual”setting, the vane will automatically shift down 10°lower than previous setting.
    In“Auto”setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
    downward.
     2. Heating Mode
     • W hen the Powerful Mode is set, the set temperature will be automatically increased 3°C against the present setting
    temperature (Higher temperature: 30°C).
     • The Fan Speed will shift as shown below:
     • Vertical Airflow Direction:-
    In“Manual”setting, the vane will automatically shift down 5°lower than previous setting.
    In“Auto”setting, the vane will automatically shift between upper and lower limit depend ing on the intake air temperature as
    Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5°downward.
     3. Powerful modewilloperate for 15 minutes only.
     4. Powerful Mode willstop if:
     • Powerful mode button is pressed again.
     • Stopped by ON / OFF switch.
     • Timer-off activates.
     • Quiet mode button is pressed.
     • Operating mode is changed.
    33
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							8.11. Ionizer Operation
    Purpose
    To provide fresh air effect to user by producing minus ion in discharge air.
    Control Condition
    a. Ionizer Only Operation.
     1. When air-conditioner unit is at“OFF”conditio n (standby) and ION operation button at remocon is pressed.
    Fan & ionizer on, ION LED illuminates, but power LED maintain off. (1
    →2)
    However, fan speed can be adjusted later by customer during this operation.
    Air flow direction (Horizontal Vane) control:
    Follow vane direction control at cooling mode.
    Horizontal vane can be changed by customer during ion only operation.
     2. Ion only operation can be off by pressed ION button again. (2
    →1)
     3. It can be changed to previous operated mode (Auto, Heat, Cool, Dry) + ion operation by OFF/ON switch. (2
    →4)
     4. During ion only operation, if power failure occur, after power resume, ionizer & air-conditioner resumes immediately.
     5. After error = 24 times, (about 11h 30 min.), ion & fan off with Ion LED blinks continuously.
    (Detail refer to Ionizer Error detection control.)
    b. Operation Mode + Ionizer Operation.
     1. Ionising Operation Start Condition
    When air-conditioner unit is in“ON”conditio n (Heat, Cool, Dry, Auto mode) and ION operation button at remote controller
    is pressed. Ionizer on & ION LED illuminates. (3
    →4)
    Power LED also illuminates.
     2. Ionising Operation Stop Condition
    When one of thefollowin g conditio n is satisfied, ION operation stops.
     a. Stoppe d by ON/OFF switch.
     b. Timer OFF activates.
     c. ION operation button is pressed again.
     d. ION feedba ck signal shows error.
    34
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							Case 1a: Ionizer only operation (12h delaytimer ON)
    Case 2a: Ionizer only operation (24h real time timer ON)
    Case 1b: Ionizer only operation (12h delaytimer OFF)
    Case 2b: Ionizer only operation (24h real time timer OFF)
     3. Ionizer operation status is not memorised after off. After OFF,when operation is“ON”again, air-conditio ner operates without
    ionizer operation.
    However, during Cool mode etc. + ionizer operation, if there is a power failure & then power resume, A/con shall on at that
    mode + ionizer operation.
    c. Timer during ionizer operation
    Refer to case study in next page for detail.
    8.11.1. Ionizer Error Detection Control
    A. Purpose
    To inform user that error occurs at ionizer system so that repairing job can be carried out.
    B. Two type oferror detection control:
    (a) WhenIonizer is ON (example case: Ionizer shorted, ionizer over current protection)
     • During ionizer ON operation, when feed back voltage = Lo (micon input) is detected, Ion is OFF. If feedba ck = Lo for 11
    hrs 30 min, ION LED blinks continuously.
     • To cancel ion LED blinking, press ion button at remocon (or forcible operation sw at a/con unit). If ion button is pressed
    again, ion LED blinks again.
     • The error can be reset by:
    i) Operation ON/OFF button press to operation OFF.
    ii) Forcible switch press to operation OFF.
    iii) Operation OFF due to Timer OFF reach.
    iv) Timer set ON & operation from ON to OFF (only applica ble to 12 hrs timer models).
    (b) WhenIonizer is OFF (example case: ionizer connecting wire loose)
     • During air conditio ner is at standby or ON operation and ionizer at OFF conditio n, if ionizer feed back voltage = Hi (micon
    input) is detected, Ionizer breakdown detection control is activated and ion LED immediately blinks.
     • To cancel Ion LED blinking, press ion button at remocon (or forcible operation sw at a/con unit). If ion button is pressed
    again, ion LED blinks again.
     • During ionizer at breakdown conditio n, if ionizer feedba ck voltage = Lo (become OK), ion LED will stop blinking.
    8.11.2. Ionizer Operation case study
    35
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							Case 3a: Operation Mode + Ionizer (12h delaytimer ON)
    Case 4a: Operation Mode + Ionizer (24h real time timer ON)
    Case 5a: Ionizer only operation (24h real time timer ON)
    Case 6a: Ionizer only operation (12 delaytimer ON)
    Case 7a: Operation Mode + Ionizer (12 delaytimer ON)
    Case 3b: Operation Mode + Ionizer (12h delaytimer OFF)
    Case 4b: Operation Mode + Ionizer (24h real time timer OFF)
    Case 5b: Ionizer only operation (24h real time timer OFF)
    Case 6b: Ionizer only operation (24h real time timer ON)
    Case 7b: Operation Mode + Ionizer (24h real time timer ON)
    Case 8: Ionizer only operation (Auto Fan) & shift to Cool Mode
    36
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							Note:
     1. 24 times checking: Actual Ion ON for 10s & OFF for 1s 30 min continuously for 24 times.
     2. 24 times count will be cleared when followin g conditio ns happen .
    a) 24 times count over, b) Ionizer cancel if press Ion button or power reset, c) Ion f/b sgnl OK.
     3. Error protection will be cleared when followin g conditio ns happen .
    a) Power reset, b) Remocon operation ON/OFF button press, c) Forcible operation press, d) Opt OFF due to Timer OFF
     4. Ion auto restart: Ion will auto restart if Actual Ion was ON with no error protection control before power shutdown. Otherwise
    Ion will not auto restart.
     5. Ion LED blinking can ON/OFF during error protection by followin g conditio ns:
    a) Press remocon ion button
    b) Press emergency opt SW to OFF blinking.
    37
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							38
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							9 Operating Instructions
    SAFETY PRECAUTIONS
    Before operating, please read the following
    “Safety Precautions” carefully.
    To prevent personal injury, injury to others and
    property damage, the following instructions must be
    followed.
    Incorrect operation due to failure to follow instructions
    will cause harm or damage, the seriousness of which
    is classified as follow:
    ! WarningThis sign warns of death or serious injury.
    ! CautionThis sign warns of damage to property.
    The instructions to be followed are classified by the
    following symbols:
    This symbol (with a white background) denotes an
    action that is PROHIBITED.
    These symbols (with a black background) denote
    actions that are COMPULSORY.
    OFF
    Installation Precautions
    ! Warning
    This room air conditioner must be
    earthed.
    Improper grounding could cause
    electric shock.
    Ensure that the drainage piping is
    connected properly.
    Otherwise, water will leak out.
    Do not install the unit in a
    potentially explosive atmosphere.
    Gas leak near the unit could cause
    fire.
    Do not install, remove and reinstall the unit by
    yourself.
    Improper installation will cause leakage, electric
    shock or fire. Please engage an authorized dealer
    or specialist for the installation work.
    ! Caution
    Operation Precautions
    ! WarningThis sign warns of death or serious injury.
    Do not share outlet.
    Do not insert plug to operate the unit. Do not
    pull out plug to stop the unit.
    Do not operate with wet hands.
    Do not damage or modify the power cord.
    Do not insert finger or other objects into the
    indoor or outdoor units.
    Do not expose directly to cold air for a long
    period.
    Plug in properly.
    Use specified power cord.
    If abnormal condition (burnt smell, etc.)
    occurs, switch off and unplug the power
    supply.
    ! CautionThis sign warns of injury.Do not pull the cord to disconnect the plug.
    Do not wash the unit with water.
    Do not use for other purposes such as
    preservation.
    Do not use any combustible equipment at
    airflow direction.
    Do not sit or place anything on the outdoor
    unit.
    Switch off the power supply before cleaning.
    Ventilate the room regularly.
    Pay attention as to whether the installation
    rack is damaged after long period of usage.
    Switch off the power supply if the unit is not
    used for a long period.
    O
    F
    F
    OFF
    NAME OF EACH PART
    Indoor Unit
    1Front Panel
    2Air Intake Vent
    3Power Supply Cord
    4Air Outlet Vent
    5Vertical Airflow Direction Louver
    6Horizontal Airflow Direction Louver
    (manually adjusted)
    7Indicator Panel
    1Auto Operation Button
    (when the front panel is opened)
    2Powerful Mode Indicator–ORANGE
    3Ionizer Mode Indicator–GREEN
    4Power Indicator–GREEN
    5Quiet Mode Indicator–ORANGE
    6Timer Mode Indicator–ORANGEIndoor Unit
    (when the front panel is opened)
    1Front Panel
    2Air Filters
    3Air Purifying Filter
    Outdoor Unit
    1Air Intake Vents
    2Ground Terminal
    (Inside cover)
    3Piping
    4Connecting Cable
    5Drain Hose
    6Air Outlet Vents
    Accessories Remote Control
     Remote Control Indication Sticker
     Remote Control Holder
     Two RO3 (AAA) dry-cell batteries or equivalent
     Air Purifying Filter
    C
    H
    E
    C
    K
    TEMPAUTAUTOONO
    F
    FAU
    TAUTOD
    RDRYFA
    NANC
    OO
    LCOOLFANANAUTAUTO
    R
    E
    S
    E
    TB
    A
    T
    T
    E
    R
    Y
    C
    L
    O
    C
    K
    MODESLEEPECONOMYFA
    N S
    PE
    E
    DAIR SWINGOFFC
    A
    N
    C
    E
    LONSETS
    te
    p12
    3T
    IM
    E
    R+
    H
    E
    AHEAT
    O
    F
    F
    /
    O
    N
    1
    2
    3
    4 5 76
    213
    1
    62
    3
    4
    5
    123 65 4
    (Catechin Air
    Purifying Filter)(Triple Deodorizing
    Filter)
    39
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    							NAME OF EACH PART
    Remote Control
    Remote Control Signal.
    Make sure it is not obstructed.
    Maximum distance : 10 m.
    Signal received sound.
    One short beep or one long beep.
    Notes for Remote Control.
    Do not throw or drop.
    Do not get it wet.
    Certain type of fluorescent lamps may affect
    signal reception. Consult your dealer.
    CHECK
    TEMPAUTOONOFF
    AUT
    AUTODR
    DRYFAN
    ANCOOL
    COOL
    FAN AUTO
    RESETCLOCK
    MODEPOWERFULQUIET
    FAN SPEEDAIR SWING
    OFFCANCELONSET12
    3
    TIMER
    OFF/ON
    AUTOMANUAL
    # !
    $
    %^
    $
    * &
    3
    5
    87
    9
    0
    6 4
    (
    2
    1
    HEAHEAT
    How  to Insert the Batteries
    1Slide down the remote control cover completely
    2Insert the batteries
    –Be sure the direction is correct
    –12.00 at display - flashing
    Set the current time (CLOCK) immediately to
    prevent battery exhaustion.
    About the batteries
    Can be used for approximately one year.
    Observe the following when replacing the
    batteries
    Replace with new batteries of the same type.
    Do not use rechargeable batteries (Ni-Cd).
    Remove the batteries if the unit is not going to be
    used for a long period. 1Signal Transmitter
    2Operation Display
    3Ionizer Mode Operation Button
    4Room Temperature Setting Button
    (illuminating button)
    5Operation Mode Selection Button
    6Quiet Mode Operation Button
    7Auto Airflow Direction Button
    8ON-Timer Button
    9OFF-Timer Button
    0Reset Point
    (Press with fine-tipped object to clear the memory)
    !OFF/ON Button
    (illuminating button)
    @Powerful Mode Operation Button
    #Fan Speed Selection Button
    $Manual Airflow Direction Selection Button
    %Timer Set Button
    ^Timer Cancellation Button
    &Time-Setting Button
    *Clock Button
    (Remote Control Cover
    CHECK
    AUTOOFAUTO HEATDRY
    FA N COOL
    FA NAUTO
    AUTO
    RESETCLOCK
    AIR 
    SWI
    NGOFF
    CANCEL
    12
    3
    TIMER
    POWERFUL
    AUTO
    MANUALECONO
    MYSLEO
    N
    SETFAN SPEED
    MODE
    2
    1
    1.5V1.5V
    PREPARATION BEFORE OPERATION
    Indoor Unit
    1Connect the power supply cord to an independent
    power supply
    2Open the front panel
    3Remove the air filters
    4Fit the air purifying filters in place
    5Insert the air filters
    6Close the front panel
    Remote Control–To set the current time
    1Press 1.2Then press 2 to increase or decrease the time.3Press 1 again.
    Set time at display will light up.
    CHECK
    AUTO
    AUTO HEAT DRY FANCOOL
    FA NAUTO
    RESETCLOCK
    FAN SPEEDAIR SWING
    OFFCANCELONSET12
    3
    TIMER
    AUTOMANUAL
    1 2
    621
    4 5 3
    Setting TemperaturePress 3 to increase or decrease the temperature.
    The temperature can be set between 16°C ~ 30°C.
    Recommended temperature:
    During AUTO Operation, press 3 to select:-
    Operation with 2°C higher than the standard
    temperature.
    Operation with the standard temperature.
    Operation with 2°C lower than the standard
    temperature.
    Standard Temperature
    Cooling Model
    Once the Automatic Operation is selected, the indoor
    temperature sensor operates automatically to select
    the desired operation mode with Cooling or Soft Dry.
    After the operation mode has been selected, the
    mode does not change.
    Heat Pump Model
    At the beginning of the automatic operation, Heating,
    Cooling or Soft Dry is automatically selected according
    to the indoor temperature.
    The operation mode changes every hour, when
    necessary.
    Operation
    Cooling
    Soft DryStandard
    temperature
    25°C
    22°C Indoor
    temperature
    23°C
    HOW TO  OPERATE
    To start the operation
    Press 1.
    POWER indicator (green) on the indoor unit will light
    up.
    To stop, press once more.
    Setting Mode
    Press 2 to select:-
    Cooling Model
    AUTO–Automatic Operation
    COOL–Cooling Operation
    DRY–Soft Dry Operation
    FAN–Air Circulation Operation
    Heat Pump Model
    AUTO–Automatic Operation
    HEAT–Heating Operation
    COOL–Cooling Operation
    DRY–Soft Dry Operation
    Operation
    Cooling
    Soft Dry
    HeatingStandard
    temperature
    25°C
    22°C
    21°C Indoor
    temperature
    23°C
    20°C
    Heat Pump Model
    COOL–> 26°C ~ 28°C
    DRY–>   1°C ~   2°C
    lower than the
    room temperature
    HEAT–> 20°C ~ 24°C
    Cooling Model
    COOL–> 26°C ~ 28°C
    DRY–>   1°C ~   2°C
    lower than the
    room temperatureO
    F
    FONHEA
    HEATDR
    DRY
    FAN
    AN COOL
    COOL
    CHECK
    T
    E
    MP
    AUT
    AUTO
    A
    UT AUTO
    FA
    N AN A
    U
    T AUTO
    RESETCLOCK
    A
    IR
     S
    W
    IN
    GOFF
    C
    A
    NC
    E
    L
    12
    3
    TIM
    ER
    OFF/ONAUTO
    MANUALQU
    IETPOWERFULON
    S
    E
    TFAN SPEED
    MODE
    2
    3
    5
    1
    6
    4
    40
    CS-W7CKP CU-W7CKP 5 / CS-W9CKP CU-W9CKP 5 / CS-W12CKP CU-W12CKP5 
    						
    All Panasonic manuals Comments (0)

    Related Manuals for Panasonic Cs W7ckp Cs W9ckp Cs W7ckp Series Repair Manual