Home > Panasonic > Air Conditioner > Panasonic Cs W50btp Cu W50bbp8 Cu V50bbp8 Repair Manual

Panasonic Cs W50btp Cu W50bbp8 Cu V50bbp8 Repair Manual

Here you can view all the pages of manual Panasonic Cs W50btp Cu W50bbp8 Cu V50bbp8 Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.

Page 31

11 OPERATING CHARACTERISTIC
HEAT PUMPMODEL
ModelMain Power SourceCompressor MotorIndoor Unit
Fan MotorOutdoor unit
Fan MotorElectrical Data (50Hz)
VoltageFrequencyS.C.R.C. (A)IPT (kW)R.C.IPTR.C.IPTF.C.(A)IPT(kW)
(v)(Hz)(A)Cool/HeatCool/Heat(A)(kW)(A)(kW)Cool/HeatCool/Heat
HEATCS-W50BTP38050698.62 / 8.624.97 / 5.070.740.160.990.229.20 / 9.205.35 / 5.45
PUMPCU-W50BBP840050698.62 / 8.624.95 / 5.050.730.171.020.239.20 / 9.205.35 / 5.45
MODEL41550698.61 / 8.614.93 / 5.030.730.171.040.259.20 / 9.205.35 / 5.45...

Page 32

12 FAN PERFORMANCE
32 

Page 33

13 SAFETY DEVICE
INDOOR UNIT
Heat pump model
Indoor unitCS-W50BTP
Cooling only model
For Fan Motor Protection,OFF°C135
Internal Protector (49F)ON°C85
For Control Protection, FuseCUTA3.15
OUTDOOR UNIT
Outdoor UnitHeat pump model50HzCU- W50BBP8
Cooling
only
model50HzCU- V50BBP8
60Hz-
For Refrigerant Cycle,OFFMPa
(*1)3.1
High Pressure Switch (63H1)ONMPa
(*1)2.3
ForOFFA15
Compressor(Heat pump)
Over CurrentOFFA15
Protection(Cooling50Hz
only)A-
60Hz
RESET-Automatic
Discharge Temp.Compressor°C120...

Page 34

14 COMPONENT SPECIFICATION
Compressor
ModelHeat pump model50HzCU-W50BBP8
Cooling only50HzCU-V50BBP8
model
60Hz-
Compressor Modelsingle-phase-
3-phaseZR68KCE-TFD
Compressor TypeSCROLL
No. of Cylinders1
Revolutionr/min2,900
Piston Displacementm3/h16.18
Motor TypeStarting MethodDirect on-line Starting
Rated OutputkW4.1
Poles2
Insulation ClassE
OilTypeMMMAPOE
ChargeL1.8
Evaporator
ModelsCS-W50BTP
Tube MaterialCopper tube
Outer Diametermm7.0
Thicknessmm0.27
Row3
No. of Tubes/Row12
Fin MaterialAluminium...

Page 35

15 CAPACITY AND POWER CONSUMPTION
15.1. HEATING PERFORMANCE
ModelHeating capacities are based on conditions below.
CS-W50BTPO3 phase, 50Hz, 400V
OIndoor temperature 20°C D.B.T.
OOutdoor temperature 7°C D.B. 6°C W.B.T.
OStandard air volume 35m
3/min
CU-W50BBP8
Heating capacity 14.0 kW
Inlet AirOutdoor Temperatu re (°C W.B.T.)
Air Volume (m3/min)Entering Air
D.B.T. (°C)-6°C0°C6°C12°C
H.C.IPTH.C.IPTH.C.IPTH.C.IPT
1511.683.8214.004.3616.85.1819.56.10
352011.044.0313.204.6316.05.4519.26.32...

Page 36

15.2. COOLING PERFORMANCE
CS-W50B TP
ModelCooling capacities are based on conditions below.
CS-W50BTP Cooling
capacity 14.0 kWO1 phase, 50Hz, 230V
OIndoor temperature 27°C D.B.T. 19°C W.B.T.
OOutdoor temperature 35°C D.B.T.
OStandard air volume 35m
3/min
Cooling capacity
IndoorOutdoor Temperatu re (°C D.B.T.)
Air2530354043
Temperatu reTCTCTCTCTC
D.B.W.B.kWkWkWkWkW
1714.5714.0013.1712.1811.47
231915.3914.9114.1513.1912.52
2216.8116.3615.6114.6013.91
1714.4013.8413.0412.0911.41...

Page 37

TC = Total Coolin g Capacity
IPT = Power Consumption
37 

Page 38

16 DISCHARGE AND SUCTION PRESSURE
38 

Page 39

17 REACHING DISTANCE
39 

Page 40

18 SOUNDDATA
40 