Page 31
11 OPERATING CHARACTERISTIC HEAT PUMPMODEL ModelMain Power SourceCompressor MotorIndoor Unit Fan MotorOutdoor unit Fan MotorElectrical Data (50Hz) VoltageFrequencyS.C.R.C. (A)IPT (kW)R.C.IPTR.C.IPTF.C.(A)IPT(kW) (v)(Hz)(A)Cool/HeatCool/Heat(A)(kW)(A)(kW)Cool/HeatCool/Heat HEATCS-W50BTP38050698.62 / 8.624.97 / 5.070.740.160.990.229.20 / 9.205.35 / 5.45 PUMPCU-W50BBP840050698.62 / 8.624.95 / 5.050.730.171.020.239.20 / 9.205.35 / 5.45 MODEL41550698.61 / 8.614.93 / 5.030.730.171.040.259.20 / 9.205.35 / 5.45...
Page 33
13 SAFETY DEVICE INDOOR UNIT Heat pump model Indoor unitCS-W50BTP Cooling only model For Fan Motor Protection,OFF°C135 Internal Protector (49F)ON°C85 For Control Protection, FuseCUTA3.15 OUTDOOR UNIT Outdoor UnitHeat pump model50HzCU- W50BBP8 Cooling only model50HzCU- V50BBP8 60Hz- For Refrigerant Cycle,OFFMPa (*1)3.1 High Pressure Switch (63H1)ONMPa (*1)2.3 ForOFFA15 Compressor(Heat pump) Over CurrentOFFA15 Protection(Cooling50Hz only)A- 60Hz RESET-Automatic Discharge Temp.Compressor°C120...
Page 34
14 COMPONENT SPECIFICATION Compressor ModelHeat pump model50HzCU-W50BBP8 Cooling only50HzCU-V50BBP8 model 60Hz- Compressor Modelsingle-phase- 3-phaseZR68KCE-TFD Compressor TypeSCROLL No. of Cylinders1 Revolutionr/min2,900 Piston Displacementm3/h16.18 Motor TypeStarting MethodDirect on-line Starting Rated OutputkW4.1 Poles2 Insulation ClassE OilTypeMMMAPOE ChargeL1.8 Evaporator ModelsCS-W50BTP Tube MaterialCopper tube Outer Diametermm7.0 Thicknessmm0.27 Row3 No. of Tubes/Row12 Fin MaterialAluminium...
Page 35
15 CAPACITY AND POWER CONSUMPTION 15.1. HEATING PERFORMANCE ModelHeating capacities are based on conditions below. CS-W50BTPO3 phase, 50Hz, 400V OIndoor temperature 20°C D.B.T. OOutdoor temperature 7°C D.B. 6°C W.B.T. OStandard air volume 35m 3/min CU-W50BBP8 Heating capacity 14.0 kW Inlet AirOutdoor Temperatu re (°C W.B.T.) Air Volume (m3/min)Entering Air D.B.T. (°C)-6°C0°C6°C12°C H.C.IPTH.C.IPTH.C.IPTH.C.IPT 1511.683.8214.004.3616.85.1819.56.10 352011.044.0313.204.6316.05.4519.26.32...
Page 36
15.2. COOLING PERFORMANCE CS-W50B TP ModelCooling capacities are based on conditions below. CS-W50BTP Cooling capacity 14.0 kWO1 phase, 50Hz, 230V OIndoor temperature 27°C D.B.T. 19°C W.B.T. OOutdoor temperature 35°C D.B.T. OStandard air volume 35m 3/min Cooling capacity IndoorOutdoor Temperatu re (°C D.B.T.) Air2530354043 Temperatu reTCTCTCTCTC D.B.W.B.kWkWkWkWkW 1714.5714.0013.1712.1811.47 231915.3914.9114.1513.1912.52 2216.8116.3615.6114.6013.91 1714.4013.8413.0412.0911.41...