11 OPERATING CHARACTERISTIC HEAT PUMPMODEL ModelMain Power SourceCompressor MotorIndoor Unit Fan MotorOutdoor unit Fan MotorElectrical Data (50Hz) VoltageFrequencyS.C.R.C. (A)IPT (kW)R.C.IPTR.C.IPTF.C.(A)IPT(kW) (v)(Hz)(A)Cool/HeatCool/Heat(A)(kW)(A)(kW)Cool/HeatCool/Heat HEATCS-W50BTP38050698.62 / 8.624.97 / 5.070.740.160.990.229.20 / 9.205.35 / 5.45 PUMPCU-W50BBP840050698.62 / 8.624.95 / 5.050.730.171.020.239.20 / 9.205.35 / 5.45 MODEL41550698.61 / 8.614.93 / 5.030.730.171.040.259.20 / 9.205.35 / 5.45 COOLING ONLY MODEL ModelMain Power SourceCompressor MotorIndoor Unit Fan MotorOutdoor unit Fan MotorElectrical Data (50Hz) VoltageFrequencyS.C.R.C. (A)IPT (kW)R.C.IPTR.C.IPTF.C.(A)IPT(kW) (v)(Hz)(A)CoolCool(A)(kW)(A)(kW)CoolCool COOLINGCS-W50BTP38050698.624.970.740.160.990.229.205.35 ONLYCU-V50BBP840050698.624.950.730.171.020.239.205.35 MODEL41550698.614.930.730.171.040.259.205.35 Legend : S.C. = Starting Current, R.C. = Runnin g Current, IPT = Power Consumption 31
13 SAFETY DEVICE INDOOR UNIT Heat pump model Indoor unitCS-W50BTP Cooling only model For Fan Motor Protection,OFF°C135 Internal Protector (49F)ON°C85 For Control Protection, FuseCUTA3.15 OUTDOOR UNIT Outdoor UnitHeat pump model50HzCU- W50BBP8 Cooling only model50HzCU- V50BBP8 60Hz- For Refrigerant Cycle,OFFMPa (*1)3.1 High Pressure Switch (63H1)ONMPa (*1)2.3 ForOFFA15 Compressor(Heat pump) Over CurrentOFFA15 Protection(Cooling50Hz only)A- 60Hz RESET-Automatic Discharge Temp.Compressor°C120 Protection,OFF Discharge Temp. Thermistor (Th1) Liquid Compression Protection, Crankcase HeaterInput powerW34~41 Compressor Protection,OFF°C 50Hz145 Internal Protector°C 60Hz- ON°C 50Hz61 °C 60Hz- Trip time50Hz3-10sec/ 48A 60Hz- For Fan Motor Protection,OFF°C135 Internal Protector (49F)ON°C85 Heating Control Pressure Switch (Heat pump only) (Fan speed) (63H 2)OFFMPa (*1)2.50 ONMPa (*1)2.05 Cooling Control, Heat Exchanger Outlet Temp. Thermistor (Th2)Control method Th30 degree celcius ----- High speed Th < 30 degree celcius ------5 speed step control For Control Protection, FuseCUTA6.3 (*1) 1MPa = 10.2 kgf/cm2 (*2) Head Thermostat only for W/V28BBP8 & V24BB P8 33
14 COMPONENT SPECIFICATION Compressor ModelHeat pump model50HzCU-W50BBP8 Cooling only50HzCU-V50BBP8 model 60Hz- Compressor Modelsingle-phase- 3-phaseZR68KCE-TFD Compressor TypeSCROLL No. of Cylinders1 Revolutionr/min2,900 Piston Displacementm3/h16.18 Motor TypeStarting MethodDirect on-line Starting Rated OutputkW4.1 Poles2 Insulation ClassE OilTypeMMMAPOE ChargeL1.8 Evaporator ModelsCS-W50BTP Tube MaterialCopper tube Outer Diametermm7.0 Thicknessmm0.27 Row3 No. of Tubes/Row12 Fin MaterialAluminium Thicknessmm0.105 Fin PitchNO./inch19 Fin SurfaceZ Slit fin Total Face Aream20.464 FanTypeSirocco fan No. of /Unit4 Fan MotorStarting MethodDirect on-line Starting Rated OutputkW0.14 Poles4 PhaseSingle-Phase Insulation ClassE Condenser ModelsHeat pumpCU-W50BBP8 model Cooling only modelCU-V50BBP8 Tube MaterialCopper tube Outer Diametermm9.52 Thicknessmm0.3 Row2 No. of Tubes/Row46 Fin MaterialAluminium Thicknessmm0.105 Fin PitchNO./inch14 Fin SurfaceX-Louvre fin Total Face Aream21.05 FanTypePropeller Fan No. of /Unit2 FanStarting MethodDirect on-line Starting MotorRated OutputkW0.055 x 2 Poles6 PhaseSingle-Phase Insulation ClassE 34
15 CAPACITY AND POWER CONSUMPTION 15.1. HEATING PERFORMANCE ModelHeating capacities are based on conditions below. CS-W50BTPO3 phase, 50Hz, 400V OIndoor temperature 20°C D.B.T. OOutdoor temperature 7°C D.B. 6°C W.B.T. OStandard air volume 35m 3/min CU-W50BBP8 Heating capacity 14.0 kW Inlet AirOutdoor Temperatu re (°C W.B.T.) Air Volume (m3/min)Entering Air D.B.T. (°C)-6°C0°C6°C12°C H.C.IPTH.C.IPTH.C.IPTH.C.IPT 1511.683.8214.004.3616.85.1819.56.10 352011.044.0313.204.6316.05.4519.26.32 2510.404.2512.484.9115.25.7218.46.52 H.C. = Heating Capacity IPT = Power Consumption 35
15.2. COOLING PERFORMANCE CS-W50B TP ModelCooling capacities are based on conditions below. CS-W50BTP Cooling capacity 14.0 kWO1 phase, 50Hz, 230V OIndoor temperature 27°C D.B.T. 19°C W.B.T. OOutdoor temperature 35°C D.B.T. OStandard air volume 35m 3/min Cooling capacity IndoorOutdoor Temperatu re (°C D.B.T.) Air2530354043 Temperatu reTCTCTCTCTC D.B.W.B.kWkWkWkWkW 1714.5714.0013.1712.1811.47 231915.3914.9114.1513.1912.52 2216.8116.3615.6114.6013.91 1714.4013.8413.0412.0911.41 251915.4114.8814.0713.1112.42 2216.8016.2915.4914.4313.78 1714.2213.6812.9112.0011.36 271915.4314.8414.0013.0212.32 2216.7916.2215.3714.2813.65 1714.1913.6812.8812.1011.50 291915.4014.8414.0113.1212.47 2216.7216.1515.2714.3013.64 1714.1713.6911.9712.1611.59 321915.3714.8414.0113.1912.57 2216.6716.1015.2614.3113.64 Cooling power consumption IndoorOutdoor Temperatu re (°C D.B.T.) Air2530354043 Temperatu reIPTIPTIPTIPTIPT D.B.W.B.kWkWkWkWkW 174.264.615.025.515.84 23194.514.895.335.846.19 224.885.285.756.316.69 174.264.615.015.485.80 25194.544.905.345.836.18 224.905.295.766.296.67 174.274.605.015.445.77 27194.564.926.355.826.16 224.935.315.786.286.66 174.244.594.955.315.54 29194.534.915.295.685.92 225.005.405.826.256.51 174.234.584.915.235.38 32194.524.905.245.585.75 225.045.475.856.236.57 36
TC = Total Coolin g Capacity IPT = Power Consumption 37