Panasonic Cs W50btp Cu W50bbp8 Cu V50bbp8 Repair Manual
Have a look at the manual Panasonic Cs W50btp Cu W50bbp8 Cu V50bbp8 Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1 SERVICE INFORMATION 3 2 FEATURES 4 3 SPECIFICATION (HEAT PUMP TYPE ) 9 4 SPECIFICATION (COOLING ONLY TYPE ) 10 5 TECHNICAL DRAWING 11 6 CIRCUITDIAGRAM 13 7 OPERATING INSTRUCTION 25 8 REFRIGERATION CYCLE 27 9 OPERATIO N RANGE 28 10 PIPE LENGTH 29 11 OPERATING CHARACTERISTIC 31 12 FAN PERFORMANCE 32 © 2002 Matsushita Industrial Corporation. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law. CS-W50BTP CU-V50BBP8 CS-W50BTP CU-W50BBP8 13 SAFETYDEVICE 33 14 COMPONENT SPECIFICATION 34 15 CAPACITY AND POWERCONSUMPTION 35 16 DISCHARGE AND SUCTION PRESSURE 38 17 REACHING DISTANCE 39 18 SOUNDDATA 40 19 TWIN AND TRIPLE 42 20 WIRING MISTAKE PREVENTION 47 21 TEST OPERATIO N AND SELF DIAGNOSIS 48 22 SETTING OF SAVEENERGY AND THERMISTOR SWITCH 52 23 GROUP CONTROL 53 24 TROUBLESHOOTING 54 AIR CONDITIONER CONTENTS Page Page ORDER NO. MAC0210059C2
25 EMERGENCY OPERATIO N 59 26 CONTROL 60 27 WIRED REMOTE CONTROLINSTALLA TION MANUAL 70 28 WIRELESS REMOTE CONTROLINSTALLA TION MANUAL 75 29 INSTALLA TION (INDOOR UNIT) 82 30 INSTALLA TION (OUTDOOR UNIT) 92 31 REPLACEMENT PARTS 104 2
1 SERVICE INFORMATION Caution: OPb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). OPb free solder will tend to splash when heated too high (about 1100° F/600°C). Notice of Address setting for NEW Ceiling / NEW Outdoor Unit. The new Ceiling / new Outdoor models are possible to have address setting fortwin / triplecontrol or group control automatically when main powersupply is switched on. (Manual address setting is also possible by usingDSW1 switch on the indoor unit P.C. board.) However,this address setting is onlypossible when proper wiring connection is made and indoor unit must be of original unit . 1.1. Example of trouble during test operation If the below phenomenon is found during test operation, wrong address setting is possible. Theref ore, please inspect the address setting. 1. LCD display of the wiredremote control is not illuminated although the main powersupply switch is ‘on’. 2. LCD display had indicated as normal illumination when power supply switch is ‘on’, however outdoo r unit cannot be operated. (But, it is necessary to take 3 to 5 minutes for outdoor unit to start from the timing of remote control OFF/ON button is ‘on’.) (For normal operation, the outdoor unit will only start its operation after 3 to 5 minutes upon pressing the OFF/ON button.) 3. P.C. board had memorized wrong setting information. a. If main power supply is switched on with the wrong connection. b. Whenchanging the connection or combination of units due to re-installation etc. • • • • W hen changing the system from twin to triple (triple to twin). • • • • W hen changing the system from group control to normal one to one system. • • • • W hen making the replacement of units of master and slave etc. 1.2. Caution during test operation Do not touch the remote control button and do not change any wirings for one minute when the main powersupply switch is ‘on’. (Because the unit is having automatic address setting during the first one minute.) 1.3. Caution during automatic address setting When the mainpower supply switch is ‘on’, the P.C. board willautomatically memorize the connecting system. Consequently , when initial power supply is ‘on’, there mustn’t be any interchanging of units even of the same type andsame capacity unit. Theref ore, connection of the unit to another system is prohibited. 3
2.1. New design 2.1.1. Gentle curved styling • • • • The base has gentle curves which express a functional beauty . It spreads the air quietly over a wide area. 2.2. Such quietness! 2.2.1. Several new mechanism add up to low 49 dB noise (W50BT - High Fan Speed) 1. Delta throat fan A delta throat (projection) has been attached to the fan outlet to suppress the generation of vortexes. This helps maintain air flow speed even at lower fan speeds and is effective in reducing noise. 2. Reflux orifice The orifice at the intake port is equipped with an air flow guide which minimizes the flow disturbances which occur at the orifice and inside the impeller. This reduces pressure losses inside the casing and also helps reduce noise. 3. Adoption of wing-shaped vanes • • • • The vanes of the fan have been changed to “aerodynamic ” shaped vanes, so that the air flow more smoothly over the vane surfaces and noise is thus suppressed. • • • • Side filters have been adopted in the pipe partitions. These allow the air intake space to be increased and also further reduce noise. 2.2.2. Automaticswinging louvre • • • • The horizon tal air flow angle is a wide 100 degrees (manual). The louvre can swing automatically (through 70 degrees vertically) using theremote control. This increases the area of comfortable air flow and warms the air even to floor level. 2.2.3. Newly-shaped louvre • • • • The newly-shaped louvre and air outlet effectively distribute the air flow. During cooling, this stops warm air from collecting near the louvre, and prevents freezing. 2 FEATURES 4
2.3. Easy installation 2.3.1. Easy suspension • • • • A suspension bolt fixing bracket with 4-point support is attached to the main unit, which increases the space available for installa tion. 2.3.2. Two installation methods : standard andwall • • • • In additio n to the standard (1) ceiling installa tion, a wall (2) installa tion method (using a wall-hanging bracket) is available for cases where the ceiling is too high for the main unit to be suspended. 2.4. Piping 2.4.1. 3-direction pipe lead-out • • • • The refrigerant piping can lead out in one of three directions (right, rear-right and top-right), and the drain pipe direction can be selected from four directions (right, rear-right, left and rear-left). 2.5. Easy maintenance 2.5.1. Long life filter (standard equipment) • • • • In general office environments, cleanin g (maintenance ) is not required until after approximately 2,500 hours of operation, thus reducing maintenance work. • • • • For optimum comfort, it is recommended to clean the air filter every 1-1/2 months. 2.5.2. Maintenance is possible from underneath the unit. • • • • If the bottom panel is detached, the drain pan can then be removed and installe d from underneath the unit, and inspection and servicing of component such as the control panel also becomes easier. 2.6. Auto fan mode (indoor unit) • • • • Auto fan mode is added beside s high, medium and low. It automatically adjusts the fan speed according to the indoor unit’s temperature. 2.7. Hot start system (heat pump models) 2.8. Automatic changeover function (heat pump models) • • • • The unit automatically switches between cooling and heating in accordance with operating load in order to maintain a comfortable indoor temperature. 5
2.9.1. Product features • • • • Low-noise design improves comfort in surrounding areas 1. The noise-suppressing winglet fan is a result of new research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reducing air flow noise. 2. The adoption of double -orifice rings reduces air passage resistance. 3. Strengthening of the noise insulation materials in the compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed. 4. The heat exchan ger has an L-shaped design to allow air to flow more smoothly. 5. Noise is automatically reduced further during night-time operation with lower outdoor air temperatures. 2.10. Greatly improved workability increases system renewal capability • • • • Pipes that are one size larger can also be connected for renewal. − − − − If renewing the system, existing refrigerant pipes can be utilized so that only the indoor and outdoo r units need to be replaced. − − − − For example, liquid and gas pipesfrom 10years ago can be connected to current pipes with the same size or one size larger. Effective utilization of materials reduces working time and trouble. (Adaptor sockets are not supplie d.) 2.9. Low-noise outdoor units 6
• • • • Additional refrigerant charging unnecessary for 30 m − − − − All models do not require any additio nal charging of refrigerant for 30 m of pipe length. This makes installa tion much easier. • • • • Drain water dripping-prevention structure − − − − The base of the outdoo r unit is provided with a single drain hole in order to prevent drain water from leaking out of the unit. By connecting a drain elbow and a discharge pipe, water leakages can be prevented even when the unit is installe d to a wall. • • • • Save space design allows units to be installed side-by- side continuously − − − − Servicing after installa tion can be carried out by removing the front covers. • • • • Long pipe design for refrigerant pipes − − − − Maximum piping length of 50m for all models. • • • • Internal pipe connection − − − − Pipes are connected inside the units (inside the side covers), making the final appearance more attractive. − − − − Pipes can be diverted outward in any of four directions (forward, right, down, rear). − − − − Small liquid pipe diameters of 9.52mm for 50BB models, making installa tion work much easier. • • • • Centralized draining method − − − − Even when multiple outdoo r units are installe d to a wall, the drain outlets can be concentrated into a single drain pipe. This makes installa tion easier and also improves appearance. 2.11. A brand-new control method using the latest in technology • • • • Easier power supply wiring connection Power supply wiring and other wiring tasks can be carried out more easily. − − − − Twin non-polar wires used to connect indoor and outdoor units. − − − − Adoption of connection error prevention circuits for drive wires and signal wires. If a connection error is made, the relay does not operate and current does not flow to the circuit boards. • • • • Twin and Triple operation − − − − Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of different horsepowers can even be used in combination. − − − − Master unit and slave-units can be set automatically in twin and triple systems. No address setting is necessary. − − − − Multiple indoor units can be operated simultaneousl y with a single remote control. Note that individual operation is not possible. • • • • Separate indoor/outdoor unit power supplies The power supply can be connected to (1) just the outdoo r units, or (2) to both the indoor and outdoor units. • • • • Easy test operation Test operation can be carried out for both indoor and outdoor units. • • • • Automatic setting initialization function (Remote control and Indoor unit) In accordance with the indoor and outdoor units connected and the connection methods, conditions such as the connection configuration (twin or triple format) and remote- control functions such as automatic louvre operation and cooling or heating mode are automatically detected and set instantly. 7
2.12. Wired Remote Control • • • • The new design include s an easily- visible red pilot lamp. The power can be turned on and off at a single touch, without openin g the cover. • • • • Has a built-in thermistor, allowing indoor temperature detection in accordance with indoor conditions by switching with main unit thermistor. • • • • Twin non-polar wires make installa tion work easy. (10 m cable supplie d as accessory.) 2.13. Wireless Remote Control • • • • New design with compact size. (Operation range within approximately 8 m.) • • • • Built-in timer with ON/OFF timer setting (within 24 hours) WiredWireless Heat PumpCZ-RD51PCZ-RL51P CoolingCZ-RD51PCZ-RL01P NOTE: Both of the above remote control is packed separately from the indoor unit. 2.14. Group Control Equipment 8
3 SPECIFICATION (HEAT PUMP TYPE ) CS-W50BTP / CU-W50BBP8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BTPCU-W50BBP8 RemoteCZ-RD51P (Wired) ControlCZ-RL51P (Wireless) Cooling CapacitykW14.0 BTU/h47,700 Heating CapacitykW16.0 BTU/h54,600 Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/min35 cfm1236 Outside Dimension (H x W x D)mm250 x 1600 x 7001220 x 1100 x 320 inch9-27/32 x 62-31/32 x 27-9/1648-1/24 x 43-5/16 x 12-19/32 Net Weightkg47115 lbs104254 Piping ConnectionRefrigerantGasmm (inch)O.D Ø 19.05 (3/4) Flared Type Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type DrainmmO.D Ø 20I.D Ø 20 x 1 CompressorType, Number of Set-Hermetic-1 (Scroll), 1 Starting Method-Direct on-line starting MotorType-2-pole 3-phase induction motor Rated OutputkW-4.10 FanType, Number of SetSirocco fanPropeller fan MotorType4-pole single phase induction motor6-pole single phase induction motor Rated OutputkW0.140.055 x 2 Air-heat ExchangerSlit-fin typeX-Louvre-fintype Refrigerant ControlCoolCapillary tube- Heat-Capillary tube Refrigerant Oil (Charged)litre-MMMAPOE Refrigerant (Charged)kg-R407C (4.4) (oz)(155) Running AdjustmentControl SwitchWireless or Wired RemoteControl- Room Temperatu reThermosta t (Main Body)- Safety DevicesInternal protector for compressor, Internal thermostat for fan motor, Crankcase heater, High and heating pressure switch, Current transformer Noise LeveldB (A)Hi 49 Lo 45Cooling 56, Heating 58 Power level dBCooling : Hi 66 Lo 62 Heating : Hi 66 Lo 62Cooling 69, Heating 71 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.) 2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.), 6°CW.B.(42.8°F W.B.) ELECTRICAL DATA (50Hz) ITEM / MODELCS-W50BTP, CU-W50BBP8 Condition by JIS B 8615 VoltsV380400415 Phase3N3N3N Power ConsumptionkWCool5.355.355.35 Heat5.455.455.45 Running CurrentACool9.29.29.2 Heat9.29.29.2 Starting CurrentA696969 Power Factor%Cool888481 Heat908682 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz 9
4 SPECIFICATION (COOLING ONLY TYPE ) CS-W50B TP / CU-V50BB P8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BTPCU-V50BBP8 RemoteCZ-RD51P (Wired) ControlCZ-RL01P (Wireless) Cooling CapacitykW14.0 BTU/h47,700 Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/min35 cfm1236 Outside Dimension (H x W x D)mm250 x 1600 x 7001220 x 1100 x 320 inch9-27/32 x 62-31/32 x 27-9/1648-1/24 x 43-5/16 x 12-19/32 Net Weightkg47112 lbs104247 Piping ConnectionRefrigerantGasmm (inch)O.D Ø 19.05 (3/4) Flared Type Liquidmm (inch)O.D Ø 9.52 (3/8) Flared Type DrainmmO.D Ø 20I.D Ø 20 x 1 CompressorType, Number of Set-Hermetic-1 (Scroll), 1 Starting Method-Direct on-line starting MotorType-2-pole 3-phase induction motor Rated OutputkW-4.10 FanType, Number of SetSirocco fanPropeller fan MotorType4-pole single phase induction motor6-pole single phase induction motor Rated OutputkW0.140.055 x 2 Air-heat ExchangerSlit-fin typeX-Louvre-fintype Refrigerant ControlCapillary tubeCapillary tube Refrigerant Oil (Charged)litre-MMMAPOE Refrigerant (Charged)kg-R407C (4.4) (oz)(155) Running AdjustmentControl SwitchWireless or Wired RemoteControl- Room Temperatu reThermosta t (Main Body)- Safety DevicesInternal protector for compressor, Internal thermostat for fan motor, Crankcase heater, High pressure switch, Current transformer Noise LeveldB (A)Hi 49 Lo 4556 Power level dBHi 66 Lo 6269 1. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air temperature of 35°C D.B. (95°F D.B.), 24°CW.B.(75.2°F W.B.) ELECTRICAL DATA (50Hz) ITEM / MODELCS-W50BTP, CU-V50BBP8 Condition by JIS B 8615 VoltsV380400415 Phase3N3N3N Power ConsumptionkWCool5.355.355.35 Running CurrentACool9.29.29.2 Starting CurrentA696969 Power Factor%Cool888481 *Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor. PanasonicPower sourceAC, 3N~380V, 400V, 415V 50Hz 10