Page 61
26.2. Freezing prevention control 1. Operation During cooling mode operation, after 9 minutes have passed since the compressor turned on, the outdoor unit will stop its operation when the temperature detected by the indoor unit pipe temperature sensor is 2°C or lower. The indoor unit continues operating at the fan speed set by the remote control. (The remote controldisplay does not change.) 2. Cancelling This control is cancelled when the temperature detected by the indoor unit pipe temperature sensor...
Page 62
(*2) Outdoor unit fan control during heating mode operation When the compressor is on during heating mode operation (except during defrosting and when the liquid bypass valve is on), the outdoor unit fan is controlled by means of input (CN2) indicating whether the contact of the heating pressure switch on the outdoor unit circuit board is open or closed. (At the start of heating mode operation, the fan operates at HI speed.) 26.4. Hot starting 1. Whenheating mode operation starts a. Start Hot start...
Page 63
2. Whendefrosting is completed a. Start Hot start control commences when defrosting is completed. b. Operation “PREHEAT” appears on the remote controldisplay . (Other display s remain unchanged) The indoor unit fan stops. In additio n, during hot starting, the louvre stays at the horizon tal position (angle 0°C). c. Cancelling Hot starting will be cancelled when the temperature detected by the indoor unit pipe temperature sensor is 18°C or higher, or after a maximum 1 minute has passed since...
Page 64
26.5. Indoor unit fan control when thermostat is off during heating mode operation When the thermostat of the indoor unit turns off during heating mode operation, the indoor unit fan operates for 2 minutes at LOW and then stops. In additio n, 5 minutes after the thermostat of the indoor unit turns off, the indoor unit fan operates at LOW for 10 seconds, and at 3 minutes interval after that, it switches back to LOW operation for another 10 seconds. 26.6. Excess heat dissipation for indoor unit The indoor...
Page 65
26.7. Defrost mode operation time chart 1. Start and completion of defrosting a. Start During heating mode operation (including automatic heating), after the 45 minutes of defrostingcycle time has passed, defrosting starts if the temperature detected by the outdoor unit heat exchan ger outlet sensor is 2°C or lower continuously for 5 minutes. However, if the outdoor unit fan is stopped, the start of defrosting will be delaye d by 5 minutes. Then, the defrosting cycle will be 50 minutesfrom the start of...
Page 66
NOTE:If the remote control display setting temperature (To) is 29°C or higher, the heating thermostat turns on when the room temperature is 31°C. 2. Thermostat characteristics during dry mode. During dry mode operation, cooling mode operation is carried out in accordance with the indoor temperature as shown in the table below. *When modes (2) and (3) are active, dry mode operation starts when the cooling thermostat turns on. When modes (2) and (3) have been stopped, the 10 min./5 min. times have no...
Page 67
c. Thermostat characteristics during cooling mode and heating operation The thermostat on/off characteristics in both operation modes are given in the table below. 67
Page 68
26.9. Indoor unit fan control 1. Fixing at LO, MED or HI When LO, MED or HI isset, the relay switches and operation is carried out at that setting. 2. Automatic fan speed When set toAUTO, the indoor unit fan operation changes as shown in the table below. (Indoor temperature) - (Setting temperature) (Units: K) Mode / Fan SpeedHIMEDLO Cooling+3 or higher+1.5 ~ 3Less than +1.5 Heating-3 or lower-1.6 ~ - 3More than -1.5 FanMED irrespective of temperature 26.10. Forced operation during restart The...
Page 69
26.12. Outdoor unit fan excess heat dissipation control 1. When theoperation is stopped while the compressor is in operation, the outdoo r fan will run at SUPER HI fan speed for approximately 60 seconds and then stops. 26.13. Discharge temperature control 1. Operation When thedischarge temperature sensor detects a temperature of 100°C or higher during cooling mode operation, the liquid bypass valve will be turned on. 2. Cancelling When thedischarge temperature sensor detects a temperature of 70°C or...