Page 1
1 SERVICE INFORMATION 2 2 FEATURES 3 3 SPECIFICATION (HEAT PUMP TYPE) 9 4 SPECIFICATION (COOLING ONLY TYPE) 10 5 TECHNICAL DRAWING 11 6 CIRCUITDIAGRAM 13 7 OPERATING INSTRUCTION 22 8 REFRIGERATION CYCLE 24 9 OPERATIO N RANGE 25 10 PIPE LENGTH 26 11 OPERATING CHARACTERISTIC 28 12 FAN PERFORMANCE 29 13 SAFETYDEVICE 30 14 COMPONENT SPECIFICATION 31 © 2002 Matsushita Industrial Corporation. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a...
Page 2
1 SERVICE INFORMATION Caution: OPb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). OPb free solder will tend to splash when heated too high (about 1100° F/600°C). Notice of Address setting for NEW Cassette / NEW Outdoor Unit. The new Hide-away / New Outdoor models are possible to have...
Page 3
2.1. Variety of excellent features 2.1.1. Compact design, height 27 cm • • • • The height has been reduced to 27 cm, the equipment can be installe d in limited spaces. 2.1.2. Versatile installation • • • • The indoor unit is designed in order that air will also enter from below, for easier installa tion under different conditions. • • • • The equipment has two drain outlets on the right and left side for adoption to the installa tion conditions in the buildin g. 2.1.3. Easy...
Page 4
[Product features] 2.2.1. Low-noise design improves in surrounding areas 1. The noise-suppressing winglet fan is a result of new research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reduces air flow noise. 2. The adoption of double -orifice rings reduces air passage resistance. 3. Strengthening of the noise insulation materials in the compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed. 4. The...
Page 5
2.3.1. Pipes that are one size larger can also be connected for renewal • • • • If renewing the system, existing refrigerant pipes can be utilized so that only the indoor units and outdoo r units need to be replaced. • • • • For example, liquid and gas pipesfrom 10years ago can be connected to current pipes with the same size for one size larger. Effective utilization of materials reduces working time and trouble. (Adaptor sockets are not supplie d.) 2.3.2. Additional refrigerant...
Page 6
2.3.8. Centralized draining method • • • • Even when multiple outdoo r units are installe d to a wall, the drain outlets can be concentrated into a single drain pipe. This makes installa tion easier and also improve appearance. 2.4. A brand-new control method using the latest in technology 2.4.1. Powersupplywiring is also easier Power supply wiring and other wiring tasks can be carried out more easily. • • • • Twin non-polar wires used to connect indoor and outdoo r units. • • •...
Page 7
Q QQ Q Twin combination table 2.5. New refrigerant Series [R407C] pipe installation 2.5.1. Procedure • • • • The new refrigerant (R407C) has a different composition to the previously-used refrigerant (R22), so some contents and method of pipe installa tion and charging work are different from before. Care should be taken whencarrying out this work. 2.5.2. Installation and precautions 2.5.2.1. Before installation 1. Determine the installa tion division. 2. Check the refrigerant to be used....
Page 8
11. Air-tightness test. For the final check, there should be no pressure drop when 3.3 MPa is applied for 24 hours. 12. Vacuum drying. Vacuum draw time60 min. or more * Vacuum pump capacity 60 l/min. or higher • • • • Drawing the vacuum will remove any moisture. • • • • The pressure after vacuum drawing should be 755 mmHg or less. • • • • Use a special vacuum pump (with backflow-prevention mechanism). • • • • Gas must never be used for air purging. 13. Additio nal...
Page 9
3 SPECIFICATION (HEAT PUMP TYPE) CS-W50BD3P / CU-W50BBP8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BD3PCU-W50BBP8 Cooling CapacitykW14.00 (BTU/h)(47,700) Heating CapacitykW16.00 (BTU/h)(54,600) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 40 cfmHi 1413 External Static PressuremmAqHi 7- PaHi 69 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm270 x (1500 + 100) x 6501220 x 1100 x 320 Net Weightkg (lbs)56...
Page 10
4 SPECIFICATION (COOLING ONLY TYPE) CS-W50B D3P / CU-V50BB P8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BD3PCU-V50BBP8 Cooling CapacitykW14.00 (BTU/h)(47,700) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 40- cfmHi 1413 External Static PressuremmAqHi 7- PaHi 69 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm270 x (1500 + 100) x 6501220 x 1100 x 320 Net Weightkg (lbs)56 (123)112 (247) Piping...