Panasonic Cs W50bd2p Cu V50bbp8 Cu W50bbp8 Repair Manual
Here you can view all the pages of manual Panasonic Cs W50bd2p Cu V50bbp8 Cu W50bbp8 Repair Manual. The Panasonic manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 1
1 SERVICE INFORMATION 2 2 FEATURES 3 3 SPECIFICATION (HEAT PUMP TYPE) 9 4 SPECIFICATION (COOLING ONLY TYPE) 10 5 TECHNICAL DRAWING 11 6 CIRCUITDIAGRAM 13 7 OPERATING INSTRUCTION 22 8 REFRIGERATION CYCLE 24 9 OPERATIO N RANGE 25 10 PIPE LENGTH 26 11 OPERATING CHARACTERISTIC 28 12 FAN PERFORMANCE 29 13 SAFETYDEVICE 30 14 COMPONENT SPECIFICATION 31 © 2002 Matsushita Industrial Corporation. Sdn. Bhd. (11969-T). All rights reserved. Unauthorized copying and distribution is a...
Page 2
1 SERVICE INFORMATION Caution: OPb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). OPb free solder will tend to splash when heated too high (about 1100° F/600°C). Notice of Address setting for NEW Cassette / NEW Outdoor Unit. The new Hide-Away / New Outdoor models are possible to have...
Page 3
2.1. Variety of excellent features 2.1.1. Compact design • • • • The height is only 36cm and can be installe d even where the space is limited. 2.1.2. Automatic restart function • • • • W hen the electric power comes back after a power failure, the unit itself automatically restarts the operation in the pre- failure mode. 2.1.3. Auto fanmode (indoor unit) • • • • Auto fan mode is added beside s Hi, Me and Lo. It automatically adjusts the fan speed according to the indoor...
Page 4
[Product features] 2.2.1. Low-noise design improves in surrounding areas 1. The noise-suppressing winglet fan is a result of new research into vane design theory. The unique curved shape suppresses the generation of vortexes, thus reduces air flow noise. 2. The adoption of double -orifice rings reduces air passage resistance. 3. Strengthening of the noise insulation materials in the compressor and the sealing-in of mechanical noise allows vibration noise to be greatly enclosed and suppressed. 4. The...
Page 5
2.3.1. Pipes that are one size larger can also be connected for renewal • • • • If renewing the system, existing refrigerant pipes can be utilized so that only the indoor units need to be replaced. • • • • For example, liquid and gas pipesfrom 10years ago can be connected to current pipes with the same size for one size larger. Effective utilization of materials reduces working time and trouble. (Adaptor sockets are not supplie d.) 2.3.2. Additional refrigerant charging unnecessary for...
Page 6
2.4.2. Separate indoor/outdoor unit power supplies The power supply can be connected to (1) just the outdoo r units, or (2) to both indoor and outdoor units. 2.4.5. Twin operation • • • • Simultaneous air conditioning of wide spaces and corners is possible. Indoor units of different horsepowers and models can even be used in combination. • • • • Master unit and slave-units can be set automatically in twin systems. No address setting is necessary. • • • • Multiple indoor units...
Page 7
2.5.2.2. Installation 1. Install the sleeve and the insert. 2. Install the indoor unit. 3. Install the refrigerant piping. • • • • Pipe materials • • • • Refrigerant pipes which were previously used to carry R22 must not be re-used. If replacing the indoor and outdoo r units, be sure to replace all refrigerant pipes also. • • • • Check the pipe thickness. • • • • Clean the inside of the pipes. • • • • W hen storing pipes, seal both ends of the pipes and...
Page 8
Q Boiling point at normal atmospheric pressure (reference) RefrigerantHFC32HFC125HFC134a Boiling point-52°C-49°C-26°C • • • • Use a special gauge manifo ld and charging hose. • • • • If refrigerant leaks occur, replace all of the refrigerant (same as for R22). • • • • Note that a R22 leak detector cannot be use to detect leaks. • • • • Refer to the Installation Instructions include d for the correct charging amoun t. • • • • Make a note of additio nal...
Page 9
3 SPECIFICATION (HEAT PUMP TYPE) CS-W50BD2P / CU-W50BBP8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BD2PCU-W50BBP8 Cooling CapacitykW14.00 (BTU/h)(47,700) Heating CapacitykW16.00 (BTU/h)(54,600) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 38- cfmHi 1342 External Static PressurePaHi 98 Me 81 Lo 70- mmAqHi 10 Me 8.3 Lo 7.2 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm360 x (1000 + 100) x 6501220 x 1100 x...
Page 10
4 SPECIFICATION (COOLING ONLY TYPE) CS-W50B D2P / CU-V50BB P8 ITEM / MODELIndoor UnitOutdoor unit Main BodyCS-W50BD2PCU-V50BBP8 Cooling CapacitykW14.00 (BTU/h)(47,700) Refrigerant Charge-lessm30 Standard Air Volume for High Speedm3/minHi 38- cfmHi 1342 External Static PressurePaHi 98 Me 81 Lo 70- mmAqHi 10 Me 8.3 Lo 7.2 Air InletBackward SuctionBack sided Suction Air OutletFront blow-outFront blow-out Outside Dimension (H x W x D)mm360 x (1000 + 100) x 6501220 x 1100 x 320 Net Weightkg (lbs)59 (130)112...