Page 71

DES Release NotesPanasonic@CPC-EX, Version 1 .O (Preliminary)June 
lo,1996
Notes
lThe Operator Access address applies only to DBS systems using the new
(1995) NANP dialing plan (FF7 
l# 17# l#), and to TRS types 2-6 (IRS types 0
and 1 do not allow outbound dialing; TRS type 7 allows all dialing).
lIf “O-only”, “00-only”, “10XxX0-only “, or “1OlXXXXO-only” calls are
restricted (settings 0 or 2), the system will wait 6 seconds before automatically
disconnecting the call. However, if the user dials...

Page 72

Panasonic@DES Release Notes
June 
lo,1996CPC-EX, Version 1 .O (Preliminary)
Maximum Time Priority Route Tables
DescriptionCPC-EX allows a maximum of 8 Time Priority Route Tables to be used during
LCR programming. 
(CPC-AIL/B allows a maximum of 16 Time Priority Route
Tables. This number is reduced with CPC-EX since very few systems require
more than 3 of these tables and the saved memory space will allow for a planned
future enhancement.)
The DBS uses Time Priority Route Tables to route calls to the...

Page 73

DBS Release NotesPanasonic@CPC-EX, Version 
1 .O (Preliminary)June lo,1996. 
ISDN Support
DescriptionCPC-EX supports ISDN-PR.l (Integrated Services Digital Network -- Primary Rate
Interface). This ISDN Interface provides 23 voice channels 
(“B” channels) and a
control channel 
(“D” channel) over a 4-wire circuit.
One program address, for Trunk Circuit Type (FF2 (trunk 
#)# 21# ), has been
modified to allow for ISDN. This modification is described below. In addition,
CPC-EX provides several new...

Page 74

Panasonic@DBS Release Notes
June 
lo,1996CPC-EX, Version 1 .O (Preliminary)
Modifications to SMDR
DescriptionStation Message Detail Recording (SMDR) provides detailed call records of
outgoing calls. SMDR records can be output to a printer or an external call
accounting system. Additional call record types have been added to the SMDR
feature to support network calls and ISDN calls.
Figure 17 shows the SMDR format for CPC-EX. New values added for CPC-EX
are shaded.Figure 17. SMDR Format for CPC-EX...

Page 75

DBS Release NotesPanasonicQCPC-EX, Version 1 .O (Preliminary)June 
lo,1996
Setting Modified for SMDR
Values have been redefined for the SMDR Start Timer. The following table shows the new values.
Note: These new values apply to CPC-EX only.
Programming-
to specify the SMDR Display Start Timer for CO Calls...
FFI 2# 1# 2# (O-1 O)#
t
0=4sec6 =16 set
1=6 set7=18sec
2=8 set8 =20 set
3=10 set9 =25 set
4=12 set10 =30 set
5=14 set
Related Programming
l FFl (System): SMDR Print
l FFl (System): Parity Check
l FFl...

Page 76

Panasonic@
June lo,1996DBS Release Notes
CPC-EX, Version 1 .O (Preliminary)
Hardware Requirementsl
A printer or external call accounting system is required to receive SMDR data.
Considerationsl
Unlike other CPC circuit cards, the CPC-EX supports two serial ports. Serial Port
1 is labeled CN4 and is located on the backplane. Serial Port 2 is labeled 
CN5 and
is located on the front of the CPC-EX card. Serial Port 2 requires a special
interface cable..
Be sure to select the correct port to output SMDR...

Page 77

DES Release NotesPanasonicBCPC-EX, Version 1 .O (Preliminary)June 
lo,1996
Modification to Tl Signaling Types
DescriptionThe default values for Tl Incoming and Outgoing Signal Types have been
changed to set “Wink Start” as the default. This will allow easier programming of
E&M trunks.
Outgoing Signaling Type
Programming
FFl 8# 4# 6# (I-64)# 3# (O-2)#
f-f
Trunk Number (l-64)
O=Immediate Start
l=Wink Start
2=Dial Tone Start
Incoming Signaling Type
‘Programming
FFI 8# 4# 6#(l-64)#4# (0 or l)#I
Trunk Number...

Page 78

m-111
3amsa
Digital Business SystemSection 300
Installation
n n n n
n n n n
q mmm
q mmm
mmmm
n n n n
n n n n
n n n n
Mmmm
n n n n
mm
q mmm
~Klcl
Reissueb 5/22/97
Dot. No. DBS-70-30
m
m
q
r-lII
10 

Page 79

t contatnwaningsor cautions to
Productspowered by electricity
should
beserviced @repairedoniybyexperienced
professional technicians. Any attempt to service or repair the product or products dealt
with in this service information by anyone else could result in serious injury or death.
FCC Warning
This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used properly, that
is, in strict accordance with the instruction manual, may cause interference to radio and...

Page 80

Table of Contents
Purpose..................................................................................................................................xRelatedDocuments..............................................................................................................
.x
Chapter 1. Requirements. . . . . . . . . . . . ..*.......................I-1Model Numbers......................................................................................................................l-3...
Start reading Panasonic Cpc+AII/B Digital Business System Release Notes Manual

Related Manuals for Panasonic Cpc+AII/B Digital Business System Release Notes Manual

All Panasonic manuals