Page 71
DES Release NotesPanasonic@CPC-EX, Version 1 .O (Preliminary)June lo,1996 Notes lThe Operator Access address applies only to DBS systems using the new (1995) NANP dialing plan (FF7 l# 17# l#), and to TRS types 2-6 (IRS types 0 and 1 do not allow outbound dialing; TRS type 7 allows all dialing). lIf “O-only”, “00-only”, “10XxX0-only “, or “1OlXXXXO-only” calls are restricted (settings 0 or 2), the system will wait 6 seconds before automatically disconnecting the call. However, if the user dials...
Page 72
Panasonic@DES Release Notes June lo,1996CPC-EX, Version 1 .O (Preliminary) Maximum Time Priority Route Tables DescriptionCPC-EX allows a maximum of 8 Time Priority Route Tables to be used during LCR programming. (CPC-AIL/B allows a maximum of 16 Time Priority Route Tables. This number is reduced with CPC-EX since very few systems require more than 3 of these tables and the saved memory space will allow for a planned future enhancement.) The DBS uses Time Priority Route Tables to route calls to the...
Page 73
DBS Release NotesPanasonic@CPC-EX, Version 1 .O (Preliminary)June lo,1996. ISDN Support DescriptionCPC-EX supports ISDN-PR.l (Integrated Services Digital Network -- Primary Rate Interface). This ISDN Interface provides 23 voice channels (“B” channels) and a control channel (“D” channel) over a 4-wire circuit. One program address, for Trunk Circuit Type (FF2 (trunk #)# 21# ), has been modified to allow for ISDN. This modification is described below. In addition, CPC-EX provides several new...
Page 74
Panasonic@DBS Release Notes June lo,1996CPC-EX, Version 1 .O (Preliminary) Modifications to SMDR DescriptionStation Message Detail Recording (SMDR) provides detailed call records of outgoing calls. SMDR records can be output to a printer or an external call accounting system. Additional call record types have been added to the SMDR feature to support network calls and ISDN calls. Figure 17 shows the SMDR format for CPC-EX. New values added for CPC-EX are shaded.Figure 17. SMDR Format for CPC-EX...
Page 75
DBS Release NotesPanasonicQCPC-EX, Version 1 .O (Preliminary)June lo,1996 Setting Modified for SMDR Values have been redefined for the SMDR Start Timer. The following table shows the new values. Note: These new values apply to CPC-EX only. Programming- to specify the SMDR Display Start Timer for CO Calls... FFI 2# 1# 2# (O-1 O)# t 0=4sec6 =16 set 1=6 set7=18sec 2=8 set8 =20 set 3=10 set9 =25 set 4=12 set10 =30 set 5=14 set Related Programming l FFl (System): SMDR Print l FFl (System): Parity Check l FFl...
Page 76
Panasonic@ June lo,1996DBS Release Notes CPC-EX, Version 1 .O (Preliminary) Hardware Requirementsl A printer or external call accounting system is required to receive SMDR data. Considerationsl Unlike other CPC circuit cards, the CPC-EX supports two serial ports. Serial Port 1 is labeled CN4 and is located on the backplane. Serial Port 2 is labeled CN5 and is located on the front of the CPC-EX card. Serial Port 2 requires a special interface cable.. Be sure to select the correct port to output SMDR...
Page 77
DES Release NotesPanasonicBCPC-EX, Version 1 .O (Preliminary)June lo,1996 Modification to Tl Signaling Types DescriptionThe default values for Tl Incoming and Outgoing Signal Types have been changed to set “Wink Start” as the default. This will allow easier programming of E&M trunks. Outgoing Signaling Type Programming FFl 8# 4# 6# (I-64)# 3# (O-2)# f-f Trunk Number (l-64) O=Immediate Start l=Wink Start 2=Dial Tone Start Incoming Signaling Type ‘Programming FFI 8# 4# 6#(l-64)#4# (0 or l)#I Trunk Number...
Page 78
m-111 3amsa Digital Business SystemSection 300 Installation n n n n n n n n q mmm q mmm mmmm n n n n n n n n n n n n Mmmm n n n n mm q mmm ~Klcl Reissueb 5/22/97 Dot. No. DBS-70-30 m m q r-lII 10
Page 79
t contatnwaningsor cautions to Productspowered by electricity should beserviced @repairedoniybyexperienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death. FCC Warning This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used properly, that is, in strict accordance with the instruction manual, may cause interference to radio and...
Page 80
Table of Contents Purpose..................................................................................................................................xRelatedDocuments.............................................................................................................. .x Chapter 1. Requirements. . . . . . . . . . . . ..*.......................I-1Model Numbers......................................................................................................................l-3...