Page 121
Chapter 3. Cabinet InstallationSection 3004nstallation Test Phone Guidelines lThe test terminal (CN3) on the DBS Connector Panel can be used to connect a display phone for programming. The test terminal can be used for initial programming before extension cabling is completed. lThe test terminal is turned on by flipping SW1 on the Connector Panel to the “Test” position. When SW 1 is in the test position, extension ports 7 and 8 are connected through the test terminal. When SW1 is not in the test...
Page 122
Section 300~installationChapter 3. Cabinet Installation ‘igure 3-18. Test telephone connection Test PhoneDSS ConsoleSW1 TEST=Ports 7 and 8 are connected through CN3 Note: Port 7 must be assigned as extension 101 and the DSS/72 assigned as telephone type 13 for the DSW72 to operate. Two-Conductor Cable (Port 7)Two-Conductor Cable (Port 8)ST-TEST ST=Ports 7 and 8 are connected through the MDF 1 / To the I/telephone DBS-70-300DBS Manual - Issued 8/l/953-19
Page 123
Chapter 4. Trunks and Lines This chapter describes trunk and line installation. Some peripheral equipment also requires trunk and/or line interfaces (for example, door phones or power failure units). See Chapter 5 for instructions on connecting peripheral equipment through trunks or lines. This chapter covers the following topics:: Topic Trunks Page Loop-S tart TrunksI 4-7 Ground Start and DID ‘$X%nks4-9 Tl Interface/4-11 Lines/4-3 1 Analog Extensions4-37 Digital Extensions4-40 DSS/724-40 EM/244-42...
Page 125
Section 300~InstallationChapter 4. Trunks and Lines Trunks Trunk Connectors Each DBS cabinet is provided with one main trunk connector, labeled CN 1. In addition, a trunk expansion connector (VB-43120) can be added to the DBS to provide eight additional trunk connections. (The trunk expansion connector is also labeled CNl.) Figure 4- 1 shows the maximum number of trunks that can be connected when both trunk connectors are used with a DBS 96. imre4-l.DBS trunk connedions (DBS 96)MDF 0 coDBS-70-300DBS...
Page 126
The number of trunks that can be connected through the main trunk connector depends on the type of system you have and the number of trunk cards installed. Table 4-l shows the main trunks and expansion trunks available with each system type. Chapter 6 includes trunk maximums for two-cabinet systems. Table 4-l.Main trunks and expansion trunks provided with each system type Sys tern TypeMain Trunk NumbersExpansion Trunk Numbers DBS 401-89-16 DBS 721-1617-24 DBS 96 l-2425-32Trunk Connector Pinouts Table...
Page 127
Section 300~Installation Table 4-2.Pinouts and trunk numbers for the main trunk connector.Chapter 4. Trunks and Lines BR-BK BK-SL SLBK YL-BL BLYL YL-OR. 14 40 15 41 16 42 14R 15T 15R 16T 16R 17T Trunk I5 Trunk16 Trunk !7.a lDBS 96 only, 1. Tmnks connections for a trunk card iostallcd in the EC/IRK slot appear on the Trunk Port Expansion ccmwctor as described on the next page. DBS-70-300DBS Manual - Issued 8/l/954-5
Page 128
Chapter 4. Trunks and LinesSection 300~Installation Table 4-3.Pinouts and trunk numbers for trunk expansion connector CNITrunk Slot Color PinDesig.Trunk Assignments According to CodeNo.’ System Type DES40DBSl?DBS96 EGTRKW-H-BL26ITTN&TrunkTrunk BL-WH11R91725 WH-OR 272TTN&Trunk Trunk OR-WH22R101826 WH-Gti283TTrunkTrunkTrunk 1. Only the first 8 pairs on the trunk expansion connector are used. 4-6DBS Manual - Issued 8/l/95DBS-70-300
Page 129
Section 300~InstallationChapter 4. Trunks and Lines Loop-Start Trunks Guidelines lTwo versions of the loop-start trunk are available: the four-port version (IQ-435 10) and the eight-port version (VB-43511). lThe following procedure covers loop-start trunk installation using the main trunk connector. For instructions on using the expansion trunk connector, see “Trunk and Line Expansion” on page 4-43 lFor pinouts and color codes for the main trunk connector, see Table 4-2 on lnstalla tion page 4-5....
Page 130
Chapter 4. Trunks and Lines Section 3004nstallation 2.Install the loop-start trunk in a trunk slot. 3.Use a standard 50-pin cable to connect the trunks from the MDF to the main trunk connector CNl. Installation with Caller ID 1.Remove the cover from the L-TRK card (VB-435 11A). This cover should be set aside since it cannot be reinstalled with a Caller ID Board installed. 2.Cut strap Jl on the L-TRK card as shown in Figure 4-2. 3.Set switches SW1 through SW8 on the L-‘IRK card (VB-43511A) to OFF.A...