Panasonic Control Unit BM-ED500 Operating Instructions
Here you can view all the pages of manual Panasonic Control Unit BM-ED500 Operating Instructions. The Panasonic manuals for Security system are available online for free. You can easily download all the documents as PDF.
Page 11
11 INSTALLATIONS AND SETTINGS INSTALLATIONS WARNING The installations described in the figures should be made by qualified service personnel or system installers. ■Caution on Installation Secure the control unit with the supplied mounting bracket to prevent vibration, dropping and injury. Notes: •Keep the unit: ·in the temperature between 0 °C and 40 °C (between 32 °F and 104 °F) and the humidity between 30 % and 80 %. •Keep the unit away from: ·vibration. (It may cause invalid recognition or injury.)...
Page 12
UL Listed NEC type CM or CL2, RG-6/U type Recommended distance: 20 m or less Maximum distance: 100 m ItemUse For communication between iris cameras and the control unit Solder both ends with BNC plugs. DC power cable 12 Item number/Recommended type UL style 1015 or equivalents*1 (resistance of both ends: 0.03 Ω/m or less)Necessary when supplying DC power from the control unit to iris cameras Maximum distance: 20 m Solder both ends of the cable with M3 screw clamp terminals. LAN cable UL style 1666,...
Page 13
13 ■Installation The following is the procedure to mount the control unit over the wall with the supplied mounting bracket. When mounting, follow the procedure. After mounting the plate, secure the control unit to the mounting plate. Otherwise, it may drop and cause damage or injury. Caution: This system must be installed within the protected promise in accordance with the National Electrical Code (NFPA70), and the local authorities having jurisdiction. 1. Attach the anchor into the wall and attach the...
Page 14
3. Connect iris cameras and electric locks as following, and then LAN cable to the Ethernet port. Wrap the supplied ferrite cores around the cables connected to the electric locks and LAN. 14 2. Pass the power cable through the upper cable holes, and then mount the control unit over the wall. Make two holes to attach the supplied bushing or a flexible metal conduit described in the figure. Use a metal conduit. Use a metal conduit. Cable holes 123456789 RESET0MIN +–BZ1 VR1 MAXR1R7R6R4R51 1 9 OFF...
Page 15
15 4. If you make the control unit output alarm signals to external devices and relate them to the alarm signals from the iris cam- eras or the control unit, connect the devices to ALARM OUT 1 to 8. For example, you can start alarm-related recording by connecting ALARM OUT and a recorder’s alarm input connector. Notes: •Alarm-related operations and alarm output timing are configurable through the administration PC. (Refer to the administra- tor’s guide supplied with the administration software.) •The...
Page 16
Enrollment mode Description and setting Operation mode Set to this mode when you make iris cameras enroll people. Set to this mode when you configure the control units operations via the administration PC. (Refer to the administrator’s guide supplied with the administration software .) 16 SETTINGS ■Description To use the control unit, the following settings are necessary with the setting switches or numeric buttons on the setting board. •Setting/confirmation of the operation mode/IP address (Operation...
Page 17
17 ●IP address/Subnet mask/Gateway address setting The following are the factory default settings of IP address and default gateway address. IP address:172.27.1.2 Subnet mask:255.255.255.0 Gateway address:172.27.1.254 Note:You need to change these addresses depending on the classification or condition of LAN, which connects the control unit. If the settings of IP address and default gateway address are not correspondent with those in the LAN classification or condition, you cannot control this unit...
Page 18
Setting Electric lock 1 not connected Locking/Unlocking with continuous electricity Locking/Unlocking with instantaneous/ pulse electricity #1* #2* OFF ON ON OFF ON ON Setting 18 ●Electric lock Setting You can set the lock existence or types of electric locks with DSW 2. Electric lock 1:An electric lock which is connected to GATE 1. The factory default setting is shown in the figure. Existence and types of electric locks They are settable with Switch 1 and 2 of DSW 2. Electric lock 1 *The numeric shows...
Page 19
19 OPERATING PROCEDURES ■Turning the Power On Power switch is inside the control unit. To turn the power on, open the door with the supplied key, and then press the power switch. Close the door within 10 seconds after turn- ing on the control unit. When you turn the power on, POWER will light up, and indi- cators will light up as shown in the figures. Note:When 10 seconds have passed after opening the door with the power turned on, the door sensor detects that the door is opening, and recognition/...
Page 20
20 ■When the Door Trouble is Automatically Unrecoverable When trouble has occurred to the door and it is automati- cally unrecoverable, ALARM and S3 light up to inform you of the trouble status. In this case, turn off and turn on the power again. (Refer to p.19.) ■When the Door Trouble is Unrecoverable When trouble has occurred to the door and it is unrecover- able, all the indicators (POWER, ALARM, and S1 to S3) light up to inform you of the trouble status. In this case, turn off the power immediately...