11 INSTALLATIONS AND SETTINGS INSTALLATIONS WARNING The installations described in the figures should be made by qualified service personnel or system installers. ■Caution on Installation Secure the control unit with the supplied mounting bracket to prevent vibration, dropping and injury. Notes: •Keep the unit: ·in the temperature between 0 °C and 40 °C (between 32 °F and 104 °F) and the humidity between 30 % and 80 %. •Keep the unit away from: ·vibration. (It may cause invalid recognition or injury.) ·noise. (for example, places near air conditioners or ventilators) ·electricity. •This unit is for indoor use only. Coaxial cable(BNC)Coaxial cable(BNC) Camera power cable General-purpose power supply (24V DC,UL listed)BM-ET500 (For identification) BM-ET500 (For identification) *UL not verified Camera 1 Camera 2 System Instruction (Maximum System) OK NG OK NG OK NG (For enrollment) Administration PC* LAN cableElectric lock* Camera 3 BM-ET500 BM-ED500 POWER ALARMS3 S2 S1

UL Listed NEC type CM or CL2, RG-6/U type Recommended distance: 20 m or less Maximum distance: 100 m ItemUse For communication between iris cameras and the control unit Solder both ends with BNC plugs. DC power cable 12 Item number/Recommended type UL style 1015 or equivalents*1 (resistance of both ends: 0.03 Ω/m or less)Necessary when supplying DC power from the control unit to iris cameras Maximum distance: 20 m Solder both ends of the cable with M3 screw clamp terminals. LAN cable UL style 1666, CSA-FT4 or equivalents 10Base-T/100Base-TX (Category 5) *2 Necessary for communication between the administration PC and the control unit Anchor bolt M8 Necessary for mounting the control unit over the wall with the unicorn anchor Unicorn anchor UC-830 or equivalents Necessary for mounting the control unit over the wall ■Preparation Prepare the following items before the installation. The necessary items and their lengths differ depending on condition. ●Preparing the necessary items *2 Cables with connector covers are unusable. Note:When you use ALARM IN/OUT, GATE 1, you need another cable suited for the connectors of the external device or con- trol unit. Use the UL style 1571 or equivalents, AWG 22 -16 wire. *1 Flexible Metal Conduit (According to NEC)Coaxial cable Total area: 1.277 in. 2/100 % Trade size: 1-1/4 in. Total number of iris cameras connected 1 2Dimension and percent area of conduit and tubing 0.677 in. 2/53 % 0.396 in. 2/31 %

13 ■Installation The following is the procedure to mount the control unit over the wall with the supplied mounting bracket. When mounting, follow the procedure. After mounting the plate, secure the control unit to the mounting plate. Otherwise, it may drop and cause damage or injury. Caution: This system must be installed within the protected promise in accordance with the National Electrical Code (NFPA70), and the local authorities having jurisdiction. 1. Attach the anchor into the wall and attach the supplied mounting bracket to the anchor. Use an anchor bolt which meets the standards shown in the following figure. 10 mm (2/5 in.) or less Wall Mounting bracket 2 mm (2/25 in.) (D) Hit the anchor into the wall by referring the following figure. 30250362.4 2-4M 8 9342 280324.2 13 13 4-φ20 4-R4.5 13 The unit of length: mm Wall Type Screw Type Concrete wallTAPMARK concrete screw anchors Part No. 21230, Size 1/4 x 2-1/4 in. Plaster wallTAPMARK concrete screw anchors Part No. 21240, Size 1/4 x 2-3/4 in.

3. Connect iris cameras and electric locks as following, and then LAN cable to the Ethernet port. Wrap the supplied ferrite cores around the cables connected to the electric locks and LAN. 14 2. Pass the power cable through the upper cable holes, and then mount the control unit over the wall. Make two holes to attach the supplied bushing or a flexible metal conduit described in the figure. Use a metal conduit. Use a metal conduit. Cable holes 123456789 RESET0MIN +–BZ1 VR1 MAXR1R7R6R4R51 1 9 OFF FSK2345678# To electric locks To the hub or router (Connecting to the administration PC via LAN) To iris camerasTo electric locks POWER ALARMS3 S2 S1CN1IC11 IC13 D21 E2 E1 SW1CN1 L1 L2C7C8 C55 D1AC-IN Q1 C56 T1C35 C40 C41C47 CN2CN4CN3 MED50JRZ3A F1T6,3AL 250V IC12 C34 C32 C31L25L29 L23 IC102 E102 E101 CN504 CN503 CN903 CN901CN906 CN905 CNCN912 CNCN911 CNCN904 CN201 CN101 10BASE-T/ 100BASE-TX CAMERA 3CAMERA 2CAMERA 1 CNT/TRM_2ALARM OUT +32V – – DC-OUT +32V E4E5 E10 E10 GATE 1 GATE 2ALARM IN 19 20 E90119 20 E901 G8G7G6G5G4 G9 8 7 6 54321 G3G2G1 (L) (N) E6 E13 123456789 RESET0*#MIN +–BZ1 VR1 MAXR1R7R6R4R51 1 9 OFF FSK2345678 1 1 9 OFF FSK23456781 9 3 OFF FSK2345678 987654321 GATE1 Coaxial cable (with BNC connectors) Lock controlLock control groundGate statusGate status ground Lock status (locking)Lock status (unlocking)Lock status groundUnlocking in emergencyUnlocking in emergency ground Flexible metal conduit Trade size mm (In.)Internal diameter mm (In.)Total area 100 % mm 2(In.2)2 wires 31 % mm2(In.2)Over 2 wires 40 % mm2(In.2)1 wire 53 % mm2(In.2) 19 (3/4) 25.4 (1) 32 (1-1/4)21 (0.82) 26 (1.02) 32 (1.28) 13.5 (0.53) 21 (0.82) 32 (1.28)4.2 (0.17) 6.4 (0.25) 10 (0.40)5.4 (0.21) 8.3 (0.33) 13 (0.51)7.2 (0.28) 11 (0.43) 17 (0.68) Note:Use metal conduits when designated by the electrical regulation.

15 4. If you make the control unit output alarm signals to external devices and relate them to the alarm signals from the iris cam- eras or the control unit, connect the devices to ALARM OUT 1 to 8. For example, you can start alarm-related recording by connecting ALARM OUT and a recorder’s alarm input connector. Notes: •Alarm-related operations and alarm output timing are configurable through the administration PC. (Refer to the administra- tor’s guide supplied with the administration software.) •The alarm output connectors are not UL verified. 5. After removing the power board’s cover, connect the camera power cable to the control unit, as described in the figure. ALARM OUT G8G7G6G5G4G3G2G1 POWER ALARMS3 S2 S1CN1IC11 IC13 D21 E2 E1 SW1CN1 L1 L2C7C8 C55 D1AC-IN Q1 T1C35 C40 C41C47 CN2CN4CN3MED50JRZ3A F1T6,3AL 250V IC12 C34 C32 C31L25L29 L23 IC102 E102 E101 CN504 CN503 CN903 CN901CN906 CN905 CNCN904 CN201 CN101 10BASE-T/ 100BASE-TX CAMERA 3CAMERA 2CAMERA 1 CNT/TRM_2ALARM OUT +32V — — DC-OUT +32V E4E5E10 E10 GATE 1GATE 2ALARM IN 19 20 E90119 20 E901 G8G7G6G5G4 G987654321 G3G2G1(L) (N) E6 E13 12345*6789 RESET0#MIN+—BZ1 VR1MAXR1R7R6R4R51 1 9 OFF FSK2345678 1 1 9 OFF FSK23456781 9 3 OFF 2345678 SW1 C7 AC-IN F1 T6,3AL 25 10BASE-T/ 100BASE-TX G2G1 (L) (N) E6 E13 +32V 0V To iris cameras +32 V connectors To iris cameras 0 V connectors Camera power cable connection Start setting after finishing the installation.Secure 4 points with the supplied clamping tools. The AC socket should be installed near the equipment. Tighten the cables (except the AC power cable) and the clamping bar with two clamping tools. Use a clamping tool to separate the AC cable from other cables. Note:Connect the power cable and camera power cable after connecting electric locks and LAN cables to the control unit. The cables should be covered to prevent from pulling and pushing.

Enrollment mode Description and setting Operation mode Set to this mode when you make iris cameras enroll people. Set to this mode when you configure the control units operations via the administration PC. (Refer to the administrator’s guide supplied with the administration software .) 16 SETTINGS ■Description To use the control unit, the following settings are necessary with the setting switches or numeric buttons on the setting board. •Setting/confirmation of the operation mode/IP address (Operation mode switches) •Electric lock setting (DSW 2) You will set the existence, type, polarity and unlocking timer of electric locks. •IP address You will set if you connect the control unit to the PC via LAN and control this unit from the PC. In addition to these settings, you need the configuration through the administration PC. (Refer to the administrator’s guide of the administration software.) Note:When you set the control units operations through the administration PC, you need to change the opera- tion mode to the SETUP mode. ■To Do Setting without the Buzzer Sound When you open the door, the buzzer will beep to notify you that the door is open. Then, the recognition procedures with iris cameras will be unavailable. If you open the door for maintenance, etc., do the following procedure. 1. Open the door with the supplied key. The buzzer will beep and recognition is stopped. 2. Pull the door sensor. 3. Restart the recognition from the administration PC. You can do setting without the buzzer sound and you can continue the recognition with iris camera during the setting. (Setting changes will not be reflected until turn- ing on the power again.) 4. After the setting, close the door. The buzzer will beep again. 5. Restart the recognition from the administration PC. When you open the door again for setting, do steps 1 to 3 again. ■Operation Mode Setting The control unit has four operation modes. They are config- urable with 1 to 3 of the operation mode switches. (The fac- tory default setting is shown in the figure.) Notes: •Change the operation mode after turning off the power of the control unit. When you change the mode while power is on, the setting will not be reflected to the con- trol unit until turning on the power again. •To turn the power off, refer to p.19. POWER ALARM S3 S2 S1CN1 12345 6789 RESET0#MIN +–BZ1 VR1 MAX R1R7R6R4R51 1 9 OFF FSK2345678 Door sensor Pull this immediately after opening the door. Operation mode switches (DSW3) POWER ALARM S3 S2 S1CN1 IC102 E102 E101 CN504 CN503 CN101 12345 6789 RESET0MIN DSW1 DSW2 +—BZ1 VR1 MAX R1R7R6R4R51 1 9 OFF FSK2345678 1 1 9 OFF FSK2345678 1 9 3 OFF FSK23456781 OFF2345678 Unsettable (Do not change these positions. Error may occur.)Operation mode setting IP setting mode This is the mode to set/confirm the IP address/gateway address of the control unit. 1 1 9 OFF FSK2345678 1 1 9 OFF FSK2345678 1 1 9 OFF FSK2345678 SETUP mode Recognition modeSet to this mode when you make iris cameras recognize people. 1 1 9 OFF FSK2345678

17 ●IP address/Subnet mask/Gateway address setting The following are the factory default settings of IP address and default gateway address. IP address:172.27.1.2 Subnet mask:255.255.255.0 Gateway address:172.27.1.254 Note:You need to change these addresses depending on the classification or condition of LAN, which connects the control unit. If the settings of IP address and default gateway address are not correspondent with those in the LAN classification or condition, you cannot control this unit through the administration PC. IP address, subnet mask, or gateway address is change- able through the following procedure. 1. Turn off the power of the control unit, and then change the operation mode switches to the IP setting mode. 2. Turn on the power. Wait until the Setup indicator changes from “8” to “0”. 3. Enter the command with the numeric keys to select the address setting. IP address setting command:“113✽002#” Subnet mask setting command:“113✽003#” Gateway address setting command:“113✽004#” 4. Enter 12-digit numbers without period. (The address is composed of numbers up to 255.) Note:Enter “0” before the numerics from 0 to 99 to make it 3-digit. Example: When you enter an IP address “192.168.1.20”, enter “192168001020”. 5. Enter the address check command “113✽000#”. Address will be checked. After the checking, the result will appear on the Setup indicator. Completed:0 Failed:1 (The address may be wrong.) Parameter error:E (The digits may be wrong./✽or # may be used in the address.) 6. Turn off the power of the unit. The address will become available when you turn on the power again.Note:Before turning on the power again, change the operation mode switch to recognition or enrollment mode. ●IP address/Subnet mask/Gateway address confirmation The following is the procedure to confirm the IP address and default gateway address with the Setup indicator. 1. Turn off the power of the control unit, and then change the operation mode switches to the IP setting mode. 2. Turn on the power. Wait until the Setup indicator changes from “8” to “0”. 3. Enter the command with the numeric buttons. IP address setting command:“112✽002#” Subnet mask setting command:“112✽003#” Gateway address setting command:“112✽004#” 4. The address will appear on the LED display. The display will be switched every second to show the address. 5. Turn off the power of the unit. Note:Before turning on the power again, change the operation mode switch to recognition or enrollment mode. During the mode settingWaiting an entry During the mode settingWaiting an entry

Setting Electric lock 1 not connected Locking/Unlocking with continuous electricity Locking/Unlocking with instantaneous/ pulse electricity #1* #2* OFF ON ON OFF ON ON Setting 18 ●Electric lock Setting You can set the lock existence or types of electric locks with DSW 2. Electric lock 1:An electric lock which is connected to GATE 1. The factory default setting is shown in the figure. Existence and types of electric locks They are settable with Switch 1 and 2 of DSW 2. Electric lock 1 *The numeric shows the setting switch number. Be sure to set either one of #1 or #2 to ON. Solenoid polarity setting of electric locks It is settable with Switch 2 and 3 of DSW 2. Electric lock 1 POWER ALARM S3 S2 S1CN1 IC102 E102 E101 CN504 CN503 CN201 CN101 12345 6789 RESET0#MIN DSW1 DSW2 +—BZ1 VR1 MAX R1R7R6R4R51 1 9 OFF FSK2345678 1 1 9 OFF FSK2345678 1 9 3 OFF FSK2345678 1 OFF FSK2345678 DSW 2 Electric lock 1: Existence and type of the electric lock Electric lock 1: Solenoid polarity Electric lock 1: Unlocking timer Unsettable Unsettable Unsettable Do not change these positions. Error may occur. *The numeric shows the setting switch number. Unlocking timer activation/deactivation setting When you activate the unlocking timer of an electric lock, set Switch 4 of DSW 2 to ON. Electric lock 1 *The numeric shows the setting switch number. #3* Positive/Fail Secure ON Negative/Fail Safe OFF Setting #4* Unlocking timer activated ON Unlocking timer deactivatedOFF

19 OPERATING PROCEDURES ■Turning the Power On Power switch is inside the control unit. To turn the power on, open the door with the supplied key, and then press the power switch. Close the door within 10 seconds after turn- ing on the control unit. When you turn the power on, POWER will light up, and indi- cators will light up as shown in the figures. Note:When 10 seconds have passed after opening the door with the power turned on, the door sensor detects that the door is opening, and recognition/ enrollment becomes unavailable. This condition is not recoverable by closing the door or turning on the power switch again. (Refer to the administrator’s guide supplied with the administration software for troubleshooting.) ■Turning the Power Off 1. To turn the power off, open the door with the supplied key. The buzzer will beep and recognition will be stopped. 2. Pull the door sensor. 3. To reset the door-closed state, send the signal for oper- ation start from the administration PC. 4. Confirm the door-closed state has been reset and READY is lighting on the iris camera. 5. Turn off the control unit and close the door. Notes: •When the power of the control unit is turned off, no power is supplied to the electric lock. In this case, the status may vary depending on the lock type. If you are using a “Fail Safe” type (refer to p.18), the door can be opened with the lock deactivation. However, be careful when you are using a “Fail Secure” type (refer to p.18). The door cannot be opened with the lock activation. •Refer to the administrators guide of the administra- tion software for how to turn on/off the system. E2 E1 SW1CN1L1 L2C7C8 D1AC-IN F1T6,3AL 250V 03CN901CN906 CN905 CNCN91210BASE-T/ 100BASE-TX 6G5G4 G9 8 7 6 54321 G3G2G1 (L) (N) E6 E13 E2 E1 SW1CN1L1 L2C7C8 D1F1T6,3AL 250V 03CN901CN906 CN905 10BASE-T/ 100BASE-TX 6G5G4 G9 8 7 6 54321 G3G2G1 E6 E2 E1 SW1 F1 Power switch POWERStatus indicatorsS3 S2 S1 Power off Power on Self-diagnosis Initializing Ready This indicator is lighting. This indicator is not lighting.

20 ■When the Door Trouble is Automatically Unrecoverable When trouble has occurred to the door and it is automati- cally unrecoverable, ALARM and S3 light up to inform you of the trouble status. In this case, turn off and turn on the power again. (Refer to p.19.) ■When the Door Trouble is Unrecoverable When trouble has occurred to the door and it is unrecover- able, all the indicators (POWER, ALARM, and S1 to S3) light up to inform you of the trouble status. In this case, turn off the power immediately and refer to service personnel. (Refer to p.19 for how to turn on/off the power.) Note:When door trouble has occurred, the electric lock control will be stopped. In this case, the status may be different depending on the lock type. If you are using a “Fail Safe” type (refer to p.18), the door can be opened with the lock deactivation. However, be careful when you are using a “Fail Secure” type (refer to p.18). The door cannot be opened with the lock activation. POWER ALARMStatus indicatorsS3 S2 S1 Alarm status POWERALARM All indicators are lighting.Status indicators S3 S2 S1 Trouble status