    INSTALLATIONS AND SETTINGS
    INSTALLATIONS
    WARNING
    The installations described in the figures should be made by qualified service personnel or system installers.
    ■Caution on Installation
    Secure the control unit with the supplied mounting bracket to prevent vibration, dropping and injury.
    Notes: 
    •Keep the unit:
    ·in the temperature between 0 °C and 40 °C (between 32 °F and 104 °F) and the humidity between 30 % and 80 %.
    •Keep the unit away from:
    ·vibration. (It may cause invalid recognition or injury.)
    ·noise. (for example, places near air conditioners or ventilators)
    ·electricity.
    •This unit is for indoor use only.
    Coaxial cable(BNC)Coaxial cable(BNC)
    Camera power cable
    General-purpose
    power supply
    (24V DC,UL listed)BM-ET500
    (For identification)
    BM-ET500
    (For identification)
    *UL not verified
    Camera 1
    Camera 2
    System Instruction (Maximum System)
    OK
    NG
    OK
    NG
    OK
    NG
    (For
    enrollment)
    Administration PC*
    LAN cableElectric lock*
    Camera 3
    BM-ET500
    BM-ED500
    POWER ALARMS3 S2 S1 
    						
    							UL Listed NEC type CM or
    CL2, RG-6/U type
    Recommended distance: 20 m or less
    Maximum distance: 100 m ItemUse
    For communication between iris
    cameras and the control unit
    Solder both ends with BNC plugs. DC power cable
    12
    Item number/Recommended type
    UL style 1015 or equivalents*1
    (resistance of both ends: 0.03 Ω/m or
    less)Necessary when supplying DC power
    from the control unit to iris cameras
    Maximum distance: 20 m Solder both ends of the cable with M3
    screw clamp terminals.
    LAN cable
    UL style 1666, CSA-FT4 or equivalents
    10Base-T/100Base-TX (Category 5)
    *2
    Necessary for communication between
    the administration PC and the control
    unit
    Anchor bolt M8
    Necessary for mounting the control unit
    over the wall with the unicorn anchor 
    Unicorn anchor  UC-830 or equivalents Necessary for mounting the control unit
    over the wall
    ■Preparation
    Prepare the following items before the installation. The necessary items and their lengths differ depending on condition.
    ●Preparing the necessary items
    *2 Cables with connector covers are unusable.
    Note:When you use ALARM IN/OUT, GATE 1, you need another cable suited for the connectors of the external device or con-
    trol unit. Use the UL style 1571 or equivalents, AWG 22 -16 wire.
    *1 Flexible Metal Conduit (According to NEC)Coaxial cable
    Total area: 1.277 in.
    2/100 %
    Trade size: 1-1/4 in.
    Total number of 
    iris cameras connected
    1
    2Dimension and percent area of 
    conduit and tubing
    0.677 in.
    2/53 %
    0.396 in.
    2/31 % 
    						
    							13
    ■Installation
    The following is the procedure to mount the control unit over the wall with the supplied mounting bracket.
    When mounting, follow the procedure. After mounting the plate, secure the control unit to the mounting plate. Otherwise, it may
    drop and cause damage or injury.
    Caution: This system must be installed within the protected promise in accordance with the National Electrical Code
    (NFPA70), and the local authorities having jurisdiction.
    1. Attach the anchor into the wall and attach the supplied mounting bracket to the anchor.
    Use an anchor bolt which meets the standards shown in the following figure.
    10 mm (2/5 in.) or less
    Wall
    Mounting bracket
    2 mm (2/25 in.) (D) 
    Hit the anchor into the wall by referring the following figure.
    30250362.4
    2-4M
    8 9342
    280324.2
    13
    13
    4-φ20
    4-R4.5
    13
    The unit of length: mm
    Wall Type Screw Type
    Concrete wallTAPMARK concrete screw anchors 
    Part No. 21230, Size 1/4 x 2-1/4 in.
    Plaster wallTAPMARK concrete screw anchors 
    Part No. 21240, Size 1/4 x 2-3/4 in. 
    						
    							3. Connect iris cameras and electric locks as following, and then LAN cable to the Ethernet port.
    Wrap the supplied ferrite cores around the cables connected to the electric locks and LAN.
    14
    2. Pass the power cable through the upper cable holes, and then mount the control unit over the wall.
    Make two holes to attach the supplied bushing 
    or a flexible metal conduit described in the figure.
    Use a metal conduit.         
    Use a metal conduit.
    Cable holes
    123456789
    RESET0MIN
    +–BZ1
    VR1
    MAXR1R7R6R4R51
    1
    9
    OFF FSK2345678#
    To electric locks
    To the hub or router
    (Connecting to the administration PC via LAN) To iris camerasTo electric locks
    POWER ALARMS3 S2 S1CN1IC11 IC13
    D21
    E2 E1
    SW1CN1
    L1
    L2C7C8
    C55
    D1AC-IN
    Q1 C56
    T1C35
    C40
    C41C47
    CN2CN4CN3
    MED50JRZ3A
    F1T6,3AL 250V
    IC12
    C34
    C32
    C31L25L29
    L23
    IC102
    E102 E101 CN504 CN503
    CN903 CN901CN906 CN905
    CNCN912
    CNCN911
    CNCN904
    CN201
    CN101
    10BASE-T/
    100BASE-TX
    CAMERA 3CAMERA 2CAMERA 1
    CNT/TRM_2ALARM OUT
    +32V
    –
    – DC-OUT
    +32V
    E4E5
    E10
    E10
    GATE 1
    GATE 2ALARM IN
    19
    20
    E90119
    20
    E901
    G8G7G6G5G4
    G9 8 7 6 54321
    G3G2G1
    (L) (N)
    E6
    E13
    123456789
    RESET0*#MIN
    +–BZ1
    VR1
    MAXR1R7R6R4R51
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK23456781
    9
    3
    OFF FSK2345678
    987654321
    GATE1
    Coaxial cable (with BNC connectors)
    Lock controlLock control groundGate statusGate status ground Lock status (locking)Lock status (unlocking)Lock status groundUnlocking in emergencyUnlocking in emergency ground
    Flexible metal conduit
    Trade size
    mm (In.)Internal
    diameter
    mm (In.)Total area
    100 %
    mm
    2(In.2)2 wires
    31 %
    mm2(In.2)Over 2
    wires
    40 %
    mm2(In.2)1 wire
    53 %
    mm2(In.2)
    19 (3/4)
    25.4 (1)
    32 (1-1/4)21 (0.82)
    26 (1.02)
    32 (1.28)
    13.5 (0.53)
    21 (0.82)
    32 (1.28)4.2 (0.17)
    6.4 (0.25)
    10 (0.40)5.4 (0.21)
    8.3 (0.33)
    13 (0.51)7.2 (0.28)
    11 (0.43)
    17 (0.68)
    Note:Use metal conduits when designated by the electrical regulation. 
    						
    							15
    4. If you make the control unit output alarm signals to external devices and relate them to the alarm signals from the iris cam-
    eras or the control unit, connect the devices to ALARM OUT 1 to 8. For example, you can start alarm-related recording by
    connecting ALARM OUT and a recorder’s alarm input connector. 
    Notes: 
    •Alarm-related operations and alarm output timing are configurable through the administration PC. (Refer to the administra-
    tor’s guide supplied with the administration software.)
    •The alarm output connectors are not UL verified.
    5. After removing the power board’s cover, connect the camera power cable to the control unit, as described in the figure.
    ALARM OUT
    G8G7G6G5G4G3G2G1
    POWER ALARMS3 S2 S1CN1IC11 IC13
    D21
    E2 E1
    SW1CN1
    L1
    L2C7C8
    C55
    D1AC-IN
    Q1
    T1C35
    C40
    C41C47
    CN2CN4CN3MED50JRZ3A
    F1T6,3AL 250V
    IC12
    C34
    C32
    C31L25L29
    L23
    IC102
    E102 E101 CN504 CN503
    CN903 CN901CN906 CN905
    CNCN904
    CN201
    CN101
    10BASE-T/
    100BASE-TX
    CAMERA 3CAMERA 2CAMERA 1
    CNT/TRM_2ALARM OUT
    +32V
    —
    — DC-OUT
    +32V
    E4E5E10
    E10
    GATE 1GATE 2ALARM IN
    19
    20
    E90119
    20
    E901
    G8G7G6G5G4
    G987654321
    G3G2G1(L) (N)
    E6
    E13
    12345*6789
    RESET0#MIN+—BZ1
    VR1MAXR1R7R6R4R51
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK23456781
    9
    3
    OFF          2345678
    SW1
    C7
    AC-IN
    F1
    T6,3AL 25
    10BASE-T/
    100BASE-TX
    G2G1
    (L) (N)
    E6
    E13
    +32V
    0V
    To iris cameras  
    +32 V connectors
    To iris cameras  
    0 V connectors Camera power cable connection
    Start setting after finishing the installation.Secure 4 points 
    with the supplied 
    clamping tools.
    The AC socket should be installed near the equipment.
    Tighten the cables (except the AC power cable)
    and the clamping bar with two clamping tools.          
    Use a clamping tool to separate 
    the AC cable from other cables.
    Note:Connect the power cable and camera power cable after connecting electric locks and LAN cables to the control
    unit. The cables should be covered to prevent from pulling and pushing. 
    						
    							Enrollment mode
    Description and setting Operation mode
    Set to this mode when you make iris
    cameras enroll people. Set to this mode when you configure
    the control units operations via the
    administration PC. (Refer to the
    administrator’s guide supplied with
    the administration software
    .)
    16
    SETTINGS
    ■Description
    To use the control unit, the following settings are necessary
    with the setting switches or numeric buttons on the setting
    board.
    •Setting/confirmation of the operation mode/IP address
    (Operation mode switches)
    •Electric lock setting (DSW 2)
    You will set the existence, type, polarity and unlocking
    timer of electric locks.
    •IP address
    You will set if you connect the control unit to the PC via
    LAN and control this unit from the PC.
    In addition to these settings, you need the configuration
    through the administration PC. (Refer to the administrator’s
    guide of the administration software.)
    Note:When you set the control units operations through
    the administration PC, you need to change the opera-
    tion mode to the SETUP mode.
    ■To Do Setting without the
    Buzzer Sound
    When you open the door, the buzzer will beep to notify you
    that the door is open. Then, the recognition procedures with
    iris cameras will be unavailable. If you open the door for
    maintenance, etc., do the following procedure.
    1. Open the door with the supplied key.
    The buzzer will beep and recognition is stopped. 
    2. Pull the door sensor.
    3. Restart the recognition from the administration PC. 
    You can do setting without the buzzer sound and you
    can continue the recognition with iris camera during the
    setting. (Setting changes will not be reflected until turn-
    ing on the power again.)
    4. After the setting, close the door.
    The buzzer will beep again. 
    5. Restart the recognition from the administration PC. 
    When you open the door again for setting, do steps 1 to
    3 again.
    ■Operation Mode Setting
    The control unit has four operation modes. They are config-
    urable with 1 to 3 of the operation mode switches. (The fac-
    tory default setting is shown in the figure.)
    Notes:
    •Change the operation mode after turning off the power
    of the control unit. When you change the mode while
    power is on, the setting will not be reflected to the con-
    trol unit until turning on the power again.
    •To turn the power off, refer to p.19.
    POWER ALARM S3 S2 S1CN1
    12345
    6789
    RESET0#MIN
    +–BZ1
    VR1
    MAX
    R1R7R6R4R51
    1
    9
    OFF FSK2345678
    Door sensor
    Pull this immediately after 
    opening the door.
    Operation mode switches 
    (DSW3)
    POWER ALARM S3 S2 S1CN1
    IC102
    E102 E101 CN504 CN503
    CN101
    12345
    6789
    RESET0MIN
    DSW1
    DSW2
    +—BZ1
    VR1
    MAX
    R1R7R6R4R51
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK2345678
    1
    9
    3
    OFF FSK23456781
    OFF2345678
    Unsettable
    (Do not change these positions. Error may occur.)Operation mode 
    setting
    IP setting mode This is the mode to set/confirm the IP
    address/gateway address of the
    control unit.
    1
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK2345678
    SETUP mode
    Recognition
    modeSet to this mode when you make iris
    cameras recognize people.
    1
    1
    9
    OFF FSK2345678 
    						
    							17
    ●IP address/Subnet mask/Gateway
    address setting
    The following are the factory default settings of IP address
    and default gateway address.
    IP address:172.27.1.2
    Subnet mask:255.255.255.0
    Gateway address:172.27.1.254
    Note:You need to change these addresses depending on
    the classification or condition of LAN, which connects
    the control unit. If the settings of IP address and default
    gateway address are not correspondent with those in
    the LAN classification or condition, you cannot control
    this unit through the administration PC.
    IP address, subnet mask, or gateway address is change-
    able through the following procedure.
    1. Turn off the power of the control unit, and then change
    the operation mode switches to the IP setting mode.
    2. Turn on the power.
    Wait until the Setup indicator changes from “8” to “0”.
    3. Enter the command with the numeric keys to select the
    address setting.
    IP address setting command:“113✽002#”
    Subnet mask setting command:“113✽003#”
    Gateway address setting command:“113✽004#”
    4. Enter 12-digit numbers without period.
    (The address is composed of numbers up to 255.)
    Note:Enter “0” before the numerics from 0 to 99 to
    make it 3-digit.
    Example: When you enter an IP address
    “192.168.1.20”, enter “192168001020”.
    5. Enter the address check command “113✽000#”.
    Address will be checked. After the checking, the result
    will appear on the Setup indicator. 
    Completed:0
    Failed:1 (The address may be wrong.)
    Parameter error:E (The digits may be wrong./✽or #
    may be used in the address.)
    6. Turn off the power of the unit.
    The address will become available when you turn on
    the power again.Note:Before turning on the power again, change the
    operation mode switch to recognition or enrollment
    mode.
    ●IP address/Subnet mask/Gateway
    address confirmation
    The following is the procedure to confirm the IP address
    and default gateway address with the Setup indicator.
    1. Turn off the power of the control unit, and then change
    the operation mode switches to the IP setting mode.
    2. Turn on the power.
    Wait until the Setup indicator changes from “8” to “0”.
    3. Enter the command with the numeric buttons.
    IP address setting command:“112✽002#”
    Subnet mask setting command:“112✽003#”
    Gateway address setting command:“112✽004#”
    4. The address will appear on the LED display.
    The display will be switched every second to show the
    address.
    5. Turn off the power of the unit.
    Note:Before turning on the power again, change the
    operation mode switch to recognition or enrollment
    mode.
    During the 
    mode settingWaiting an entry
    During the 
    mode settingWaiting an entry 
    						
    							Setting
    Electric lock 1 not connected
    Locking/Unlocking with continuous
    electricity
    Locking/Unlocking with instantaneous/
    pulse electricity #1* #2*
    OFF ON
    ON OFF
    ON ON
    Setting
    18
    ●Electric lock Setting
    You can set the lock existence or types of electric locks with DSW 2.
    Electric lock 1:An electric lock which is connected to GATE 1.
    The factory default setting is shown in the figure.
    Existence and types of electric locks
    They are settable with Switch 1 and 2 of DSW 2.
    Electric lock 1
    *The numeric shows the setting switch number. Be sure
    to set either one of #1 or #2 to ON.
    Solenoid polarity setting of electric locks
    It is settable with Switch 2 and 3 of DSW 2.
    Electric lock 1
    POWER ALARM S3 S2 S1CN1
    IC102
    E102 E101 CN504 CN503
    CN201
    CN101
    12345
    6789
    RESET0#MIN
    DSW1
    DSW2
    +—BZ1
    VR1
    MAX
    R1R7R6R4R51
    1
    9
    OFF FSK2345678
    1
    1
    9
    OFF FSK2345678
    1
    9
    3
    OFF FSK2345678
    1
    OFF FSK2345678
    DSW 2
    Electric lock 1: Existence and type of the electric lock
    Electric lock 1: Solenoid polarity
    Electric lock 1: Unlocking timer
    Unsettable
    Unsettable
    Unsettable
    Do not change these positions.
     Error may occur.
    *The numeric shows the setting switch number.
    Unlocking timer activation/deactivation setting
    When you activate the unlocking timer of an electric lock,
    set Switch 4 of DSW 2 to ON.
    Electric lock 1
    *The numeric shows the setting switch number.
    #3*
    Positive/Fail Secure ON
    Negative/Fail Safe OFF
    Setting #4*
    Unlocking timer activated ON
    Unlocking timer
    deactivatedOFF 
    						
    							19
    OPERATING PROCEDURES
    ■Turning the Power On
    Power switch is inside the control unit. To turn the power
    on, open the door with the supplied key, and then press the
    power switch. Close the door within 10 seconds after turn-
    ing on the control unit.
    When you turn the power on, POWER will light up, and indi-
    cators will light up as shown in the figures.
    Note:When 10 seconds have passed after opening the
    door with the power turned on, the door sensor
    detects that the door is opening, and recognition/
    enrollment becomes unavailable. This condition is
    not recoverable by closing the door or turning on
    the power switch again. (Refer to the administrator’s
    guide supplied with the administration software for
    troubleshooting.)
    ■Turning the Power Off
    1. To turn the power off, open the door with the supplied
    key. The buzzer will beep and recognition will be
    stopped. 
    2. Pull the door sensor.
    3. To reset the door-closed state, send the signal for oper-
    ation start from the administration PC.
    4. Confirm the door-closed state has been reset and
    READY is lighting on the iris camera.
    5. Turn off the control unit and close the door.
    Notes: 
    •When the power of the control unit is turned off, no
    power is supplied to the electric lock. In this case,
    the status may vary depending on the lock type. If
    you are using a “Fail Safe” type (refer to p.18), the
    door can be opened with the lock deactivation.
    However, be careful when you are using a “Fail
    Secure” type (refer to p.18). The door cannot be
    opened with the lock activation.
    •Refer to the administrators guide of the administra-
    tion software for how to turn on/off the system.
    E2 E1
    SW1CN1L1
    L2C7C8
    D1AC-IN
    F1T6,3AL 250V
    03CN901CN906 CN905
    CNCN91210BASE-T/
    100BASE-TX
    6G5G4
    G9 8 7 6 54321
    G3G2G1
    (L) (N)
    E6
    E13
    E2 E1
    SW1CN1L1
    L2C7C8
    D1F1T6,3AL 250V
    03CN901CN906 CN905
    10BASE-T/
    100BASE-TX
    6G5G4
    G9 8 7 6 54321
    G3G2G1
    E6
    E2 E1
    SW1 F1
    Power switch
    POWERStatus indicatorsS3 S2 S1
    Power off
    Power on
    Self-diagnosis
    Initializing
    Ready
    This indicator is lighting.
    This indicator is not lighting. 
    						
    							20
    ■When the Door Trouble is
    Automatically Unrecoverable
    When trouble has occurred to the door and it is automati-
    cally unrecoverable, ALARM and S3 light up to inform you
    of the trouble status. In this case, turn off and turn on the
    power again. (Refer to p.19.)
    ■When the Door Trouble is
    Unrecoverable
    When trouble has occurred to the door and it is unrecover-
    able, all the indicators (POWER, ALARM, and S1 to S3) light
    up to inform you of the trouble status. In this case, turn off
    the power immediately and refer to service personnel.
    (Refer to p.19 for how to turn on/off the power.)
    Note:When door trouble has occurred, the electric lock
    control will be stopped. In this case, the status may be
    different depending on the lock type. If you are using a
    “Fail Safe” type (refer to p.18), the door can be opened
    with the lock deactivation. However, be careful when
    you are using a “Fail Secure” type (refer to p.18). The
    door cannot be opened with the lock activation.
    POWER
    ALARMStatus indicatorsS3 S2 S1
    Alarm status
    POWERALARM
    All indicators are lighting.Status indicators
    S3 S2 S1
    Trouble status 
    						