42 (2) Automatic White Balance Control Mode (AWC) 1. Display SET UP MENU on the monitor screen by referring to page 16. 2. Move the cursor to WHITE BAL and select AWC →PUSH SW by using the joystick. 3. Press the CAM (SET) key to start the white balance setup. PUSH SW is highlighted to indicate that white balance is being set. 4. PUSH SW returns to normal when balance setting is completed. 5. For fine adjustment of the AWC, move the cursor to AWC and press the CAM (SET) key. The AWC fine adjustment menu...
Page 42
●Motion Detector (MOTION DET) 1. Display SET UP MENU on the monitor screen by referring to page 16. 2. Move the cursor to MOTION DET and select ON or OFF by using the joystick. The factory default setting is OFF. 3. If ON is selected, press the CAM (SET) key. The MOTION DETECT menu appears. You can mask the areas in this menu. 4. Move the cursor to MASK SET and press the CAM (SET) key. 48 mask areas appear on the monitor screen. Refer to the Light Control Setting on page 37 for masking opera- tions. 5....
Page 43
44 Important Notices: •The motion detection should meet the following conditions. 1) The picture size on the screen should be larger than 1/48 of the actual picture size. 2) The contrast ratio between the object and the background picture should be more than 5 % at the maximum detection level. 3) The time it takes the object to move from one end of the screen to the other should be more than 0.1 seconds. •Also under the following conditions, mask or adjust the detection level to prevent malfunction. 1)...
Page 44
45 ●Special 2 Menu (SPECIAL2) This menu lets you adjust and set up the picture quality to meet your requirements. •Display SET UP on the monitor screen by referring to page 16. •Move the cursor to SPECIAL2 and press the F2 button of the WV- CU550B. The special menu appears on the monitor screen. For the WV-RM70, keep pressing the Right and Left switches simultaneously for 2 seconds or more. (1) Chroma Level Setting (CHROMA GAIN) 1. Move the cursor to CHROMA GAIN. The “I” cursor is highlighted. 2. While...
Page 45
46 ON:The black and white mode is selected. OFF:The color mode is selected. Note: Selecting the color mode is disabled if ALARM IN 4 is set to B/W on the Special 1 menu. 2. If you have selected AUTO, press the CAM (SET) key to open the BW AUTO submenu. 3. Select HIGH or LOW for the threshold level at which the camera automatically switches to BW or color mode. Default: HIGH. The illuminance shown below is based on the assumption that the camera is used in an area lit by halogen lamps, and that AGC on the...
Page 46
47 (9) Digital Noise Reduction (DNR) DNR may be used to improve quality under low light condi- tions. There are 4 levels of DNR, which may be selected depending on local site conditions. Factory default setting: LOW2 You may need to try different settings to find the most suitable conditions for your application. Move the cursor to DNR and select LOW1, LOW2, HIGH1 or HIGH2 by moving the joystick to the right or left. LOW1:DNR level is low. The after-image remains. LOW2:DNR level is low. The after-image...
Page 47
48 Unit Number (UNIT NUMBER) Displays the unit number set by the DIP switch. If the switch is set to 1-96, select a number by moving the joystick to the right or left. In an RS485 chain each unit must have a unique number. Factory default setting: 1. See INSTALLATION for DIP switch setting. Sub Address (SUB ADDRESS) Do not set. Baud Rate (BAUD RATE) Specifies the transmission speed (2 400, 4 800, 9 600, 19 200 bit per second) for the RS485 communica- tion. The factory default setting is 19 200. Data Bit...
Page 48
49 • The following steps of installation and connection work should be done by qualified service person- nel or system installers and should conform to all local codes. • Be sure to switch the camera off before installation and connection. • Do not install the camera near the air outlet of an air conditioner. INSTALLATION ■ Mounting the Camera Ceiling mount The figure shows an example of the camera mounted on a ceiling with a locally procured bracket. Refer to the instructions included with the bracket...
Page 49
50 1. Preparations (1) Procure a ceiling mount bracket. (2) Installation Surface CAUTION:Consult an expert on the load bearing capacity of the installa- tion surface and structure. If the sur- face is not strong enough, the cam- era may fall down. Refer to the prod- uct specifications for weights. Prepare appropriate hardware (e.g. wall nuts, anchor bolts, etc.) for fixing on the installation surface. 2. Disassembling the Camera (1) Remove the upper base from the cam- era by loosening 3 screws. Turn the...
Page 50
51 SW1AC24VONLYRS485Setting START REAR SW2 8-bit DIP SW ON 1 23 45 6 78 4-bit DIP SW O N 123 4 Camera top view Seal Switch view SW1 SW2 1234 ON5678 Switch position Returns to the factory default settings. 1234 ON5678 Switch position Multiplex-Coaxial communication 1234 ON5678 1234 ON5678 1234 ON5678 Switch positionBaud rate 1 1 1 None None None 8 8 8 19 200 9 600 4 800 Data bitParity checkStop bit Parameter selection 4. Setting the Switches The 8-bit DIP switch has two functions. It is used to...