43 • The following steps of installation and connection should be taken by qualified service personnel or system installers and should conform to all local codes. • Make sure to switch the camera off before installation and connection. • Do not install the camera near the air outlet of an air conditioner. Camera mounting base Camera Camera mounting base Fixing screw Loosen and push 1234 ON1234 ON5678 SW 1 SW 2 INSTALLATION 1. Disassembling the Camera (1) Loosen the fixing screw to separate the camera mounting base and the camera. Push up the screwdriver once before removing the screw. (2) Turn the camera mounting base approx- imately 15 degrees counterclockwise and remove the base from the camera. 2. Setting the Switches There are two DIP switches on the camera: an 8-bit switch and a 4-bit switch. The 8-bit DIP switch is used in both ways to return to the factory default settings and to specify the unit number. The 4-bit DIP switch selects ter- mination ON/OFF and half/full duplex selec- tion for RS485 communications. Switch set- tings are read in to the camera when the power is turned on. Make sure to turn it off, then turn it back on after changing the switch settings. Switch positions and func- tions are shown below. RS485 Parameter Setup The selected protocol, communication para- meters, and set unit numbers are read into the camera when power is switched on. 1. Switch off the camera. 2. Set the switch according to the function shown in the table. 3. Switch on the camera to read in the changed switch settings. 4. Switch off the camera. 5. Set the unit number with the DIP switch (see next page). 6. Switch on the camera to read in the changed switch settings. Note:The changed communication parameters are displayed on the RS485 SETUP menu after the cam- era has been switched on. Precautions 15° Turn 15° Then Camera mounting base Remove from the camera 1234 ON5678 Switch position Returns to the factory default settings. 1234 ON5678 1234 ON5678 1234 ON5678 Switch positionBaud rate 1 1 1 None None None 8 8 8 19 200 9 600 4 800 Data bitParity checkStop bit Parameter selection
44 Unit Number Switch 1, an 8-bit DIP switch, specifies unit number or returns to the factory default settings for Panasonic’s protocol. When the switch position corresponding to the unit number 1-96* is selected, setting should be made on the RS485 SET UP menu (see page 40). 1234 ON5678 SW 1 For Panasonic’s Protocol 1234 ON5678 Switch positionUnit number 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 Switch positionUnit numberSwitch positionUnit number 1-96* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2223 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 4546 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON567 8 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON56 78 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 (to be continued)
45 1234 ON5678 Switch positionUnit number 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 Switch positionUnit numberSwitch positionUnit number 69 70 71 72 73 74 75 76 7778 79 80 81 82 83 84 85 8687 88 89 90 91 92 93 94 951234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678 1234 ON5678
46 Full duplex (4 line) * BP 2 BP 1 Function Switch position Function Switch position RS485 Setting The 4-bit DIP switch in used for RS485 termination. ON Marking 1. Mark the mounting holes on the ceiling, using the removed camera mounting base as a template. 2. Fix the camera mounting base to the ceiling with four screws (not provided, M4). Note:Remove sharp edges to protect the cables.3. Assemble the Camera Reverse the disassembly procedure. Take care not to cut any cables. OFFTermination ON Termination OFF * b. Top Cable Exit Prepare a hole in the ceiling board to run the cables. 1234 ON SW 2 BP 3 BP 4 ON ON ON OFF OFF OFFHalf duplex (2 line) Notes: •Defaults are marked with *. •BP stands for Bit Position. •Daisy chain connection is not available for Full Duplex. (Only for Panasonic’s system controllers) Be sure to select a ceiling board strong enough to support 4 times the total weight of the camera. Precaution a. Sideway Cable Exit Prepare a cutout in the diecast case and decoration cover as shown in the following figures. Cutout in Diecast Case Cutout in Decoration Cover
47 5. Tighten the fixing screw M3 (provided). Notes: (1) Tighten the camera fixing screw with a screwdriver. (2) Follow the instructions given here to ensure that the camera and camera mounting base are installed safely. (3) When removing the camera from the camera mounting base, loosen and press up the camera fixing screw (M3) by using a screwdriver. 6. Fix the decoration cover to the camera mounting base. a. Sideway Cable Exit Pass the cables through the cutout made in the diecast case and decoration cover. b. Top Cable Exit Push the decoration cover against the cam- era mounting base. 15° Be sure to match the wire with the fall prevention wire fixing angle as shown below. Fall prevention wire fixing angle Ring of the fall prevention wire Cautions: •Use the supplied dust protection sheet if the camera mounting base is liable to be exposed to a dusty atmosphere. Remove the cover from the dust protection sheet, then stick the sheet on the camera mounting base. •Remove the sheet before mounting the cam- era on the base. •While the camera is separated from the base, keep the camera in the supplied poly- ethylene sack. 4. Mount the camera on the camera mounting base and rotate the camera clockwise. 3. Hook the fall prevention wire on the camera mounting base.
48 How to Assemble the Cable with the Accessory Connector Strip back the cable jacket approx. 3 mm (0.1 inch) and separate the individual conductors. Recommended wire gauge sizes for 24 V AC line #24 (0.22mm2) Copper wire size (AWG) Length of cable (approx.)(m) (ft)#22 (0.33mm2)#20 (0.52mm2)#18 (0.83mm2) 20 30 45 75 65 100 160 260 Accessory Connector Information Pin no. Power source 1 2 3 424 V AC LIVE 24 V AC NEUTRAL Ground Not use ContactUp Wire Prepare the individual conductors for clamping. Use MOLEX band tool part number 57027-5000 (for UL-Style Cable UL1015) or 57026-5000 (for UL-Style UL1007) for clamping the contacts. After clamping the contacts, push them into the proper holes in the accessory connector of this camera until they snap in place. •Shrinking the cable-entry seal is a one- time procedure. Do not shrink the cable- entry seal until it has been ascertained that the unit is functioning. •CONNECT THIS TO 24 V AC CLASS 2 POWER SUPPLY ONLY. ContactInsert UpAApprox. 3 mm (0.1 inch) Insert the wire until A position and clamp the contacts.Wire UpWire Contact Up Contact Wire Approx. 3 mm (0.1 inch) Insert the wire until A position and clamp the contacts. 1 3 2 4 • 24 V AC Power Supply Connection CAUTIONS Note:When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing operation). CONNECTIONS • The following connections should be made by qualified service personnel or system installers in accordance with all local codes. • See the reverse side of the cover page for mains lead connection. Precautions ✻The coaxial cable length (RG-59/U, BELDEN 9259) for the connec- tion is up to 900 meters (3 000 ft.)To VIDEO IN (CAMERA IN) Video output24 V AC BNC plugCoaxial cableRS485 cable Data port BNC plug Not used Not used24 V AC cable
49 • RS485 Connection Note: Use the cable that is described below for RS485 site communication. •Shielded, twisted pair cable •Low impedance •Wire gauge size is thicker than AWG #22 (0.33 mm 2). GND Brown Red Data transmission Data receptionOrange Yellow Green T (B) T (A) R (B) R (A)
50 Note:When any peripheral is turned off and turned on again, the camera is also turned off and turned back on. SYSTEM CONNECTIONS 123456789MON CAM ESC SET0ACK RESETBACK SEQFORWARD SEQ ALTDEC –1CAMINC +1CAM STOP12AUXCLOSE OPENIRISPRESETFOCUS NEAR ZOOM TELE FAR WIDESystem Controller WV-CU550550BLEFT RIGHTUP DOWN ALARMBUSYF3F4F2F1AF123456789MON CAM ESC SET0ACK RESETBACK SEQFORWARD SEQ ALTDEC –1CAMINC +1CAM STOP12AUXCLOSE OPENIRISPRESETFOCUS NEAR ZOOM TELE FAR WIDESystem Controller WV-CU550550BLEFT RIGHTUP DOWN ALARMBUSYF3F4F2F1AF123456789MON CAM ESC SET0ACK RESETBACK SEQFORWARD SEQ ALTDEC –1CAMINC +1CAM STOP12AUXCLOSE OPENIRISPRESETFOCUS NEAR ZOOM TELE FAR WIDESystem Controller WV-CU550550BLEFT RIGHTUP DOWN ALARMBUSYF3F4F2F1AF123456789MON CAM ESC SET0ACK RESETBACK SEQFORWARD SEQ ALTDEC –1CAMINC +1CAM STOP12AUXCLOSE OPENIRISPRESETFOCUS NEAR ZOOM TELE FAR WIDESystem Controller WV-CU550550BLEFT RIGHTUP DOWN ALARMBUSYF3F4F2F1AF Max. 64 cameras VCRs (up to 16) Monitors (up to 16) Printer System controller Color CCTV camera Matrix switcher Personal computer RS-232C port System status monitor Alarm inputs
51 Zoom ratio Bright object SmearWhen the camera is aimed at a bright light, such as a spotlight, or a surface that reflects bright light, smear or blooming may appear. Therefore, the camera should be operated carefully in the vicinity of extremely bright objects to avoid smear or blooming. SPECIFICATIONS PREVENTION OF BLOOMING AND SMEAR Power source3.65 mm (H) x 2.71 mm (V), 1/4” 768 (H) x 494 (V) Dimensions Focus speed Effective pixels 15.724 kHz F1.6 - 22, CLOSE Focal length BLC 24 V AC, 60 Hz 120 (D) x 191 (H) mm (4-3/4” (D) x 7-1/2” (H)) approx. 2 kg (4.4 lbs) −10°C - +50°C (14°F - 122°F) 14 W Power consumption Ambient operating temperature Weight selectable ON/OFF (SETUP MENU) x 18 +digital zoom x2 internal/line-lock / multiplexed vertical drive (VD2) 59.94 Hz 1.0 V[p-p] NTSC composite/75 Ω more than 480 lines at center (C/L) more than 350 lines at center 50 dB (AGC OFF, weight on) 2.0 lx (0.2 foot-candle) (AGC HIGH) approx. 4.5 s (TELE/WIDE) in manual mode approx. 6.0 s (FAR/NEAR) in manual mode automatic (open/close is possible)/manual 1 : 1.6 (WIDE) - 3.0 (TELE) 3.78 - 67.1 mm (17.8X) 3.2°- 51.7° 2.4°- 39.9° 1/60 (OFF), 1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000 s Scanning area Synchronization Horizontal scanning fre- quency Vertical scanning fre- quency Video output Horizontal resolution Vertical resolution Signal-to-noise ratio Minimum illumination Zoom speed Iris Maximum aperture ratio Angular field of viewH V Electronic shutter Iris range ON (LOW)/ON (MID)/ON (HIGH)/OFF AGC
52 Controls Auto focus Panning range Weights and dimensions indicated are approximate. Specifications are subject to change without notice.360°endless possible (in auto-pan mode) manual/sequential position/sort position/auto pan manual : approx. 0.1°/s - 120°/s 8-steps/64-steps sequence position : maximum approx. 300°/s 0°- 90° manual/sequential position/sort position manual : approx. 0.1°/s - 120°/s. 8-steps/64-steps sequential position : maximum approx. 300°/s pan/tilt, lens, 32 preset positions, home position Panning angle setting Panning mode Panning speed Tilting range Tilting mode Tilting speed ACCESSORIES Decoration cover .............................................................. 1 pc. Connector for 24 V AC ..................................................... 1 pc.OFF/SEQ/SORT/AUTO PAN/PATROL SEQ/SORT/AUTO PAN/PATROL PLAY preset ID, camera ID: up to 16 characters LEARN/PLAY/STOP, up to 30 seconds ON/OFF Auto mode Auto pan key Camera ID PATROL Cleaning OPTIONAL ACCESSORIES Dome cover (approx. 60 % smoked type) ............................................. WV-CS2S Dome cover (approx. 50 % smoked type) ............................................. WV-CS2SH Dome cover (approx. 70 % metal type) ................................................. WV-CS2MMANUAL/AUTO