Page 11
-9- C. The maximum extensible coaxial cable length between the camera and the monitor is shown below. Video Cable 1. It is recommended to use a monitor whose resolu- tion is at least equal to that of the camera. 2. Set the termination switch to the 75 Ωposition on the last monitor. A. Use a 75 Ωcoaxial cable. B. Set the termination switch to the 75 Ωposi- tion on the last monitor and to the Hi-Z posi- tion on the other monitors. Do not change the positions after setting. OUT IN 75Ω Hi-Z VIDEOOUT IN 75Ω...
Page 12
3. Wiring precautions: •Do not bend the coaxial cable into a curve whose radius is smaller than 10 times the cable’s diame- ter. •Never staple the cable, not even with circular sta- ples. Impedance mismatching will occur. •Never crush or pinch the cable. All of the above will change the impedance of the cable and cause poor picture quality. -10- Type of RG-59/U RG-6/U RG-11/U RG-15/Ucoaxial cable (3C-2V) (5C-2V) (7C-2V) (10C-2V) Recommended (m) 250 500 600 800 maximum cable length (ft) 825 1 650 1 980 2...
Page 13
-11- Installation of Auto Iris Lens Connector Install the lens connector (YFE4191J100) when using a video drive ALC lens. The installation should be made by qualified ser- vice personnel or system installers. (1) Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover as shown in the diagram below. The pin assignment of the lens connector is as fol- lows: Pin 1: Power source; +9V DC, 50mA max. Pin 2: Not used Pin 3: Video...
Page 14
-12- Caution for Mounting the Lens The lens mount should be a C-mount or CS-mount (1”- 32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the lens and cam- era should be secured by using the supporter. The protrusion at the rear of the lens should be as shown below: C-mount: Less than 11.5 mm (7/16”) CS-mount: Less than 7.2 mm (1/4”)1 2 Screws Flange-back Adjusting Ring Mounting the Lens Caution: Before you mount the lens, loosen the two screws on the ring, and...
Page 15
-13- The following adjustment should be made by qualified service personnel or system installers. 1. Loosen the screws on the flange-back adjusting ring. 2. Turn the flange-back adjusting ring to the desired position. Caution:When the C-mount lens is mounted, do not rotate the ring counterclockwise by force after it stops. If the ring is rotated by force, the inner lens or CCD image sensor may be dam- aged. 3. Tighten the screws on the flange-back adjusting ring. Note:If the camera is connected to the...
Page 16
-14- • Mounting from the bottom This camera is designed to be mounted from the bottom, as shown below. The mounting hole is a standard photographic pan-head screw size (1/4” - 20). •Mounting from the top Remove the mount adapter from the bottom of the camera by removing the two fixing screws. Attach the mount adapter to the top as shown in the dia- gram, then mount the camera on the mounting bracket. Make sure that the two original fixing screws are used when mounting the mount adapter as longer length...
Page 17
-15- When the camera is aimed at a bright light, such as a spot light, or a surface that reflects bright light, smear or blooming may appear. Therefore, the camera should be operated carefully in the vicinity of extremely bright objects to avoid smear or blooming. Bright object Smear PREVENTION OF BLOOMING AND SMEAR
Page 18
Pick-up Device: 768 (H) x 494 (V) pixels, Interline Transfer CCD Scanning Area: 4.9 (H) x 3.7 (V) mm (Equivalent to scanning area of 1/3” pick-up tube) Synchronization: Internal, External, Line-locked or Multiplexed vertical drive (VD2) selectable Scanning System: 2 : 1 interlace Scanning: 525 lines / 60 fields / 30 frames Horizontal: 15.734 kHz Vertical: 59.94 Hz Horizontal Resolution: 570 lines Video Output: 1.0 V[p-p] EIA composite 75 Ω/ BNC connector Signal-to-Noise Ratio: 50 dB (AGC OFF)...
Page 19
Dimensions (without lens): 67 (W) x 55 (H) x 123 (D) mm [2-5/8” (W) x 2-3/16” (H) x 4-13/16” (D)] Weights (without lens): WV-BP330: 0.62 kg(1.40lbs) WV-BP332: 0.445 kg(0.98lbs) WV-BP334: 0.470 kg(1.04lbs) Weights and dimensions indicated are approximate. Specifications are subject to change without notice. -17- STANDARD ACCESSORIES Body Cap .....................................................................................1 pc. ALC Lens Connector (YFE4191J100)...
Page 20
VERSION FRANÇAISE(FRENCH VERSION) MISE EN GARDE:AFIN DE PRÉVENIR TOUT RISQUE DINCENDIE OU DE CHOCS ÉLECTRIQUES, ÉVITER DEXPOSER CET APPAREIL À LA PLUIE OU À UNE HUMIDITÉ EXCESSIVE. Le symbole de léclair dans un triangle équilatéral indique la présence dune ten- sion suffisamment élevée pour engendrer un risque de chocs électriques. Linterférence radioélectrique générée par cet appareil numérique de type A ne dépasse pas les limites radioélectriques, section appareil numérique, du Ministère des...