Page 21

21
Display position
The position where the superimposed display appears
can be changed using setup menu item No.002
“CHARA H-POS” and No.003 (CHARA V-POS).
(See page 28)
Superimposed Screens

When the MODE button and the DATA+ button or
DATA– button are pressed, the counter display
appears temporarily while the buttons are held down
so that the setting can be checked.
Even while the MODE button is held down, settings
can still be performed using the DATA+ button or
DATA– button as the actual status is...

Page 22

22

One of the following errors may be displayed on the
third line (remaining tape amount line) in the T&S&R
mode.  (See page 74)
[NO RF]:
This appears when a blank part has been
detected on the tape.
“E-09” appears on the front panel’s counter
display.
[LOW RF]:
This appears when there is no head output.
“E-01” appears on the front panel’s counter
display.
[FAN STOP]:
This appears when the cooling fan has shut
down.
“E-70” and the counter value appear alternately
on the front panel’s counter display....

Page 23

Press the MENU-UP button or MENU-DOWN
button to move the cursor (
) to the item
where the changes are to be made.
The page can be scrolled up or down by pressing
the MENU-UP button or MENU-DOWN button
while holding down the MODE button.4
Press the DATA+ or DATA– button to change
the setting.
The setting value will flash while changes to the
setting are being performed.5
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The menu setting procedure is now terminated.7
Press the SET button to...

Page 24

24
Setup (Initial Settings)
SET–UP MENU 
NO
FACTORY (ALL)
FACTORY (NOT SYSTEM)
USER (ALL)
USER (NOT SYSTEM)
Press the MENU-UP button or MENU-DOWN
button to move the cursor to FACTORY (ALL),
and press the SET button.
OIf the cursor is moved to FACTORY (NOT
SYSTEM) and this operation is performed, all
the menus except the SYSTEM menu will be
restored to the factory settings.
OIf the cursor is moved to NO and this operation
is performed, operation will return to the menu
screen without restoring the factory...

Page 25

25
How to load the user default
settings
Set the LOCAL/MENU/REMOTE switch to the
MENU position.
The unit is now set to the menu setting mode,
and the menu screen appears on the video
monitor.1
Press the RESET button.
The unit is set to the default setting mode, and
the default setting screen appears on the video
monitor.2
Press the MENU-UP button or MENU-DOWN
button to position the cursor at LOAD, and
press the SET button.
The unit is set to the LOAD mode, and the LOAD
screen appears on the video...

Page 26

26
Setup (Initial Settings)
How to display the DIAG menu
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is now set to the DIAG display mode,
and the HOURS METER appears on the video
monitor.1
DIAG–MENU HOURS METER
H0 OPERATION 00000H
H1 DRUM RUN 00000H
H2 TAPE RUN 00000H
H3 THREADING 00000T
With the HOURS METER displayed, press the
MENU-UP button or MENU-DOWN button
while holding down the MODE button.
The software program version is displayed on the...

Page 27

27
Setup Menus
SYSTEM menu
Item Setting
No.Superimposed
displayNo.Superimposed
displayDescription of setting
The underlining denotes the factory mode setting.
05 VIDEO LEVEL 0000
0128
0255
128
0
127
For setting the video level.
This item enables the video level to be varied by up to ±3 dB.
06 SET UP LEVEL 0000
0128
0255
128
0
127
For setting the setup amount.
This item enables the setup amount to be varied by up to 10 IRE.
07 HUE 0000
0128
0255
128
0
127
For setting the hue.
This item enables the hue to...

Page 28

28
Setup Menus
BASIC menu
The underlining denotes the factory mode setting.

If the DATA+ button or DATA– button is pressed with the MODE button held down when the CHARA H-
POS and CHARA V-POS items are being set, the counter display appears temporarily, and the positions
can be set while the actual status is monitored.
Item Setting
No.Superimposed
displayNo.Superimposed
displayDescription of setting
000 SUPER
0000
0001 OFFON
For setting whether to show the superimposed display from the MONITOR
OUT...

Page 29

29
OPERATION menu
The underlining denotes the factory mode setting.
Setup Menus
Item Setting
No.Superimposed
displayNo.Superimposed
displayDescription of setting
100 LOCAL ENABLE
0000
0001
DIS
ST&EJ
For selecting the switches which can be operated on the front panel in the
REMOTE mode.
0: None of the switches can be operated.
1: Only the STOP switch and EJECT switch can be operated.
101 TAPE TIMER
0000
0001 12H24H
For selecting the CTL counter display.
0: ±12-hour display
1: 24-hour display
102 S/F/R EE...

Page 30

30
INTERFACE menu
The underlining denotes the factory mode setting.
Setup Menus
Item Setting
No.Superimposed
displayNo.Superimposed
displayDescription of setting
200 BAUD RATE 0000
0001
0002
0003
00041200
2400
4800
 960019200
For setting the RS-232C transmission speed (baud rate).
201 DATA LENGTH 00000001 8BIT7BITFor setting the RS-232C data length.
202 STOP BIT 00000001 1BIT2BITFor setting the RS-232C stop bit.
203 PARITY
0000
0001
0002 NONEODD
EVEN
For setting none, odd or even as the RS-232C parity...