Page 601
Problems with BRI service / 601 P0603534 02Modular ICS 6.1 Installer Guide 4. Test the network connection by connecting Bellcore standard terminal equipment (TE) directly to the network. 5. Verify that the loop is provisioned. 6. Verify that the loop is properly configured, including the proper loop type, SPIDs, and Network DNs. 7. Disable and re-enable the BRI Card. 8. Disable and enable the module for the Card. Out of service displays when a BRI is selected (LED for loop is lit) Possible problem...
Page 602
602 / Problems with BRI service Modular ICS 6.1 Installer GuideP0603534 02 Possible problem The card is not recognized by the ICS. Solution 1. Verify that an Expansion Cartridge with Clocking, or Clocking Cartridge is installed in the ICS. 2. Replace the card with another card of the same type. Caller hears one ring and then a fast busy signal when placing a call on a BRI line Possible problem CACH or EKTS, which are not supported by Modular ICS, is included in the ISDN services package. Solution 1....
Page 603
ICS down / 603 P0603534 02Modular ICS 6.1 Installer Guide ICS down 1. If AC power is present and the LED indicator on the ICS is off, replace the ICS power supply. 2. Disconnect all central office and station lines from the ICS. Power down the ICS by unplugging it. Replacing the ICS power supply ❶ ❷
Page 604
604 / Trunk or Station Module down Modular ICS 6.1 Installer GuideP0603534 02 Trunk or Station Module down 1. Run a Maintenance session to ensure that the Trunk Module is not disabled. See Module status on page 521. 2. Disable the module using the Maintenance heading Module status. 3. Enable the module using the Maintenance heading Module status. 4. For Trunk Module Check the external line by terminating a single-line telephone directly on the distribution block, or equivalent, which connects to...
Page 605
Data Module down / 605 P0603534 02Modular ICS 6.1 Installer Guide Data Module down 1. Run a Maintenance session to ensure that the module is not disabled. See Module status on page 521. 2. Disable the Data Module using Module status. 3. Enable the Data Module using Module status. 4. If the Data Module is still down, power down, then power up the ICS and the Data Module. If the problem persists 1. If AC power is present and the LED indicator on the Data Module is off, replace the Data Module. 2....
Page 606
606 / Problems for network or remote users Modular ICS 6.1 Installer GuideP0603534 02 Problems for network or remote users Remote feature code gets no response Possible problem A Norstar user has called into another Norstar system and is trying to activate a remote feature but gets no response after dialing the feature code. Solution 1. Make sure that the remote caller is dialing the feature code correctly. Use the asterisk (*) character, followed by the feature code, to activate a remote feature....
Page 607
Problems for network or remote users / 607 P0603534 02Modular ICS 6.1 Installer Guide Solution 1. Verify that the switch is sending the correct number of digits for the Received number length defined in your system. 2. Verify all the digit strings that the switch should be sending. 3. Check that you have defined the corresponding Received number for every target line in your system. 4. Make sure that the published telephone numbers for your network are correct. Dialed number gets stuttered dial...
Page 608
608 / Problems for network or remote users Modular ICS 6.1 Installer GuideP0603534 02 Dialed number gets dial tone instead of ringback Possible problem The remote caller has tried to reach a Norstar target line, but has reached the Norstar system instead. Norstar has mapped the incoming digits onto the Auto DN. Solution 1. Verify all the digit strings that the switch should be sending. 2. Check that you have defined the corresponding Received number for every target line in your system. 3. Check...
Page 609
Problems for network or remote users / 609 P0603534 02Modular ICS 6.1 Installer Guide Dialed number does not get through Possible problem The digits sent by a switch at a central office or in the private network did not match any Received number, the Auto DN, or the DISA DN. There is also no prime telephone assigned for the incoming trunk. In this case, the caller may hear overflow tone from the Norstar system or a recorded message from the originating switch. Solution 1. Configure a prime...
Page 610
610 / Problems for network or remote users Modular ICS 6.1 Installer GuideP0603534 02 2. Verify that the switch is sending the correct number of digits for the Received number length defined in your system. 3. If the switch at the far end is sending pulse signals, make sure they are being sent at the proper rate. Pulse digits must be 300 ms or more apart for Norstar to receive them. Possible problem If remote callers are having difficulty getting through from the public network, there may be a...