P0992642 03Modular ICS 6.0 Programming Record
 COS pswd #00Indicates the number of  the password  to  which you are assigning  information.
 Pswd 00Enter a six-digit password.
 User fltAssign a restriction filter to the Class of Service password.
 Line fltSelect whether a Class of Service password will use the default line filter or a 
different line filter (enter the two-digit filter number).
 Remote pkgSelect whether a Class of Service password will use the default remote 
package or a...

Page 102

94
Modular ICS 6.0 Programming RecordP0992642 03
 Q Timeout: Set the number of seconds the incoming call remains in the hunt group call 
queue before it is offered to the overflow position.
 Overflow: Enter the DN of the set you want the hunt group overflow calls to be 
presented.
 Name:Enter the name of the hunt group.
 Aux ringerIndicate if an external ringer will be used.
 Distinct RingUse this setting to determine the Distinctive Ring Pattern you want to use to 
identify the Hunt group....

Page 103

95
P0992642 03Modular ICS 6.0 Programming Record
 Page toneSelect whether users can hear a Page Announcement tone (²ßâ) over 
the system. 
 Page Timeout Select the number of seconds before a Page is automatically disconnected.
 Daylight timeSelect whether daylight savings time is automatically applied to the system 
clock.
 AutoTime&DateSelect whethe r time and day will automatically display.
 SWCA CntrlThis feature provides 16 feature codes which allow you to park calls on the 
system. If...

Page 104

96
Modular ICS 6.0 Programming RecordP0992642 03
 CAP assignmentUse these commands to assign the DNs of telephones to a the central 
answering position (CAP) module attached to a M7234 telephone.
 CAP 1
 CAP 2 
 CAP 3 
 CAP 4 
 CAP 5 Enter the DN of the CAP telephones.
 Dialing plan
 Private networkIf you are networking your system using dedicated PRI lines, you need to set 
up the same dialing plan on all nodes of the system.
 Ty p e(None, CDP, UDP)
This fields defines the type of...

Page 105

97
P0992642 03Modular ICS 6.0 Programming Record
 Extrnl codeEnter the one-digit external line access code. 
This code allows an M7100 telephone or a device connected to an ATA to 
access external lines. 
The external line access code cannot be the same as the:
 Call Park prefix
 Direct-dial digit
 first digit used by an internal DN
 Direct-dialSelect the digit used  to dial a Direct-dial telephone. 
The digit cannot be the same as the:
 first digit of a DN
 line pool access code
 external line...

Page 106

98
Modular ICS 6.0 Programming RecordP0992642 03
 Change DN type
(MICS-XC systems, only)These commands allow you to change DN types for the range of DNs that are 
available to either portable telephones or ISDN terminal equipment.
 Show DN:_Enter the DN for which you want to change the DN type.
 637Select whether this DN is reserved for use with a portable telephone or with 
ISDN terminal equipment.
 StateUse this softkey item to see whether a portable has been assigned to the DN.
Companion...

Page 107

99
P0992642 03Modular ICS 6.0 Programming Record
 DN length:_Select the length of DNs. 
DN length can be three to seven digits. Each increase in DN length adds the 
digit 2 to an existing DN (for example: DN 344, when increased to five digits, 
becomes 22344).
 Nat’nl lengthThe length of the telephone number  dialed to reach a person within the same 
country.
 Make/Break:Select the Make/Break ratio. The default Make/Break ratio is 40 / 60. 
 BusNameEnter the name of the business. This name displays...

Page 108

100
Modular ICS 6.0 Programming RecordP0992642 03
 AlarmThese commands allow you to configure the Alarm operation.
 Attn attemptsEnter the number of times the Alarm time feature attempts to get the attention 
of the occupant before cancelling.
 Retry intrvlEnter the interval period between each Alarm attempt.
This setting is in minute intervals.
 Attn durationSet the period for which a set alerts on each alarm attempt.
This setting is in seconds.
 Time formatChoose if alarm times are...

Page 109

101
P0992642 03Modular ICS 6.0 Programming Record
 ONN blockingAllows outgoing name and number to be blocked at the called party end on 
both analog and digital lines.
 Analog VSCAnalog Vertical service code.
 To n eVertical service code for analog tone dialing trunks.
 PulseVertical service code for analog pulse dialing trunks.
 BRI VSCBasic Rate Interface Vertical service code.
 Code:Enter the BRI code.
Software keys These commands allow you to set up access to optional features and...

Page 110

102
Modular ICS 6.0 Programming RecordP0992642 03
 Internal CSUUse to turn the internal TI channel service on or off.
The channel service unit gathers performance statistics for your T1 lines.
 CSU line bldUse to set the gain level of the transmitted signal. 
This setting only appears for DTIs that have their internal CSU turned on.
 DSX1 bldUse to set the distance between the ICS and an external channel service unit. 
This setting only appears for DTIs that have their internal CSU set to Off.
...