Page 251
Connecting the wiring / 251 P0992638 03Modular ICS 6. 0 Installer Guide BRI U wiring is not polarity sensitive. 33 Red-Green ---- ---- ---- ---- 8 Green-Red ---- ---- ---- ---- 34 Red-Brown 225 T 025-026 Assigned DN 9 Brown-Red 225 R 025-026 Assigned DN 35 Red-Slate 226 T 027-028 Assigned DN 10 Slate-Red 226 R 027-028 Assigned DN 36 Black-Blue ---- ---- ---- ---- 11 Blue-Black ---- ---- ---- ---- 37 Black-Orange ---- ---- ---- ---- 12 Orange-Black ---- ---- ---- ---- 38 Black-Green 227 T 029-030...
Page 252
252 / Connecting the wiring Modular ICS 6.0 Installer GuideP0992638 03 Wiring the BRI network interface A network interface provides the connection between the ISDN network and the Modular ICS. If the card in the ICS is configured as a T-loop, the ICS is wired to the network connection using an NT1. See T reference points on page 51 for more information about the NT1. Wiring for T network c onnection The Modular ICS supplies the NT1 functionality to a U-NT loop, allowing a direct connection to the...
Page 253
Connecting the wiring / 253 P0992638 03Modular ICS 6. 0 Installer Guide The BRI-U Card does not use or provide optional power. Some installations may not use a plug and jack for connections between the ICS (NT) and the network. The following illustration shows the pin arrangement for a Bellcore standard ISDN plug and jack. Other pin arrangements are possible. Jack and plug pin numbering 6not usedno connection 7not usedoptional power supply (-) 8not usedoptional power supply (+) 8 7 6 5 4 3 2 1...
Page 254
254 / Connecting the wiring Modular ICS 6.0 Installer GuideP0992638 03 DTI wiring Connecting the DTI to the T1 or PRI service provider Connecting the DTI to an external CSU Pin DirectionSignal 1Rx Ring (Rx from PSTN) 2Rx Tip (Rx from PSTN) 3 Rx cable shield (optional) 4Tx Ring (Tx to PSTN) 5Tx Tip (Tx to PSTN 6 Tx cable shield (optional) 7, 8 no connection Norstar ICS T1 or PRI ser vice provider Norstar ICS CSU to DTE DA15 connector Norstar CSU DT1 Pin Signal Pin 1 Rx Ring (Rx from CSU) 11 2 Rx Tip...
Page 255
Connecting the wiring / 255 P0992638 03Modular ICS 6. 0 Installer Guide Station Module wiring chart Pin Wire color Port Service Telephones SM 26 White-Blue X01 T 1 1 Blue-White X01 R 1 27 White-Orange X02 T 2 2 Orange-White X02 R 2 28 White-Green X03 T 3 3 Green-White X03 R 3 29 White-Brown X04 T 4 4 Brown-White X04 R 4 30 White-Slate X05 T 5 5Slate-White X05 R 5 31 Red-Blue X06 T 6 6 Blue-Red X06 R 6 32 Red-Orange X07 T 7 7 Orange-Red X07 R 7 33 Red-Green X08 T 8 8 Green-Red X08 R 8 34 Red-Brown X09 T...
Page 256
256 / Connecting the wiring Modular ICS 6.0 Installer GuideP0992638 03 T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec- tions are non-polarized. For an explanation of port numbering, see Port numbering on the wiring charts on page 241. 21 Blue-Violet ---- ---- no connection 47 Violet-Orange ---- ---- no connection 22 Orange-Violet ---- ---- no connection 48 Violet-Green ---- ---- no connection 23 Green-Violet ---- ---- no connection 49...
Page 257
Connecting the wiring / 257 P0992638 03Modular ICS 6. 0 Installer Guide For an explanation of port numbering, see Port numbering on the wiring charts on page 241. E&M/DISA Trunk Cartridge wiring chart Use the table, Trunk Module with E&M/DISA Trunk Cartridges, on page258 when a Trunk Module has only E&M/DISA Trunk Cartridges. If the Norstar system is being connected to another Norstar system or private branch exchange by connecting two RJ2HX/ CA2HA distribution blocks together, use the following...
Page 258
258 / Connecting the wiring Modular ICS 6.0 Installer GuideP0992638 03 Tips - When installing a mixture of E&M/DISA, DID, BRI, or Loop Start Trunk Cartridges, it is important to cross- connect the wiring for each type of TC to a separate distribution block. To verify the operation of the Norstar E&M cards and the target lines, wire the two E&M lines on the Norstar E&M back to back. The cross-connections to each distribution block must always begin at pins 26 and 1. To retain emergency telephone...
Page 259
Connecting the wiring / 259 P0992638 03Modular ICS 6. 0 Installer Guide For an explanation of port numbering, see Port numbering on the wiring charts on page 241. 13 Green-Black X06 R 6 39 Black-Brown X06 T1 6 14 Brown-Black X06 R1 6 40 Black-Slate X06 E 6 15 Slate-Black X06 SG 6 41 Yellow-Blue X06 M 6 16 Blue-Yellow X06 SB 6 Slot 3 42 Yellow-Orange X09 T 9 17 Orange-Yellow X09 R 9 43 Yellow-Green X09 T1 9 18 Green-Yellow X09 R1 9 44 Yellow-Brown X09 E 9 19 Brown-Yellow X09 SG 9 45 Yellow-Slate X09 M 9...
Page 260
260 / Connecting the wiring Modular ICS 6.0 Installer GuideP0992638 03 For an explanation of port numbering, see Port numbering on the wiring charts on page 241. For CCI connections in Service column: NC1 stands for the normally closed relay and Com1 the common relay. CCI signaling is not supported by all carriers. For carriers or installations that do not use CCI signaling, the CCI and ET connections should be treated as “no connection”. CCI wiring is a non-standard wi ring arrangement which has...