Page 11
4 Installing the -- External wiring lines 1.Cross-connect the external lines from the distribution panel directly to the modular jacks located on the left side of the KSU. Line 1 is connected to the bottom jack. (Each jack is identified with its 2.Route the line cords on the KSU (Figure 3). Connecting internal wiring 1.Plug the cable into the KSU (Figure 2.Route the cable to the distribution panel. 3.Connect the wires to the appropriate pins on the internal distribution block. (For...
Page 12
Installing the KSU 5 Internal wiring chart Chart Internal Wiring: Distribution Block PinWire ColorServiceTelephone, Port (Defaults) 26while-BlueT1 1 27while-orangeT2 2Orange-White 26White-GreenT3 3Green-White 29While-BrownT4 4&own-White 305 31Red-BlueT6 6Blue-Red 32T7 7 33T6 6 T99 35T1010 36T1111Blue-Black 37T1212A T13 39T14 14 40Slack-SlateT15 41T1616A 42Yellow-Orange Spare 17 Orange-Yellow 16Green-Yellow 44 19 45Yellow-Slate20 46Vi-BlueSpare21Spare 47Violet-Orange External Paging22(audio signal)...
Page 13
6 Installing the KSU Installing the Emergency Telephone An optional Emergency Telephone (ET) automatically connects to Line 1 when the power fails or when power to the KSU is disconnected. Note:Use only a standard single-line telephone for this purpose. Installation Procedure 1.Connect the customer supplied Emergency Telephone to the Emergency Telephone (ET) jack on the lower right hand comer of the KSU panel. 2.Label the telephone: “Emergency Telephone Only. This telephone functions only when AC power...
Page 14
1. Connect the receiver cord the telephone modular jack (indicated by the symbol at right). Route the cord through the appropriate cord guide in the base of the telephone. 2.Connect the line cord into the telephone line modular jack (indicated by the symbol at right). Route the cord through the appropriate cord guide. 3.Connect the other end of the line cord into the modular jack wired from the distribution panel. 4. When the telephone is connected to the KSU, the telephone display and indicators flash...
Page 15
1. 8 installing the telephones Installing a wall-mounted telephone 2. 3. 4. 5. Remove the beveled wall-mounting base from the back of the telephone. Grip the telephone, and with your thumbs, push on the wide edge of the base to pop it out from the telephone. Remove the receiver clip from the wall-mounting base. Install the clip in the forward lip “of the receiver rest. Use a screwdriver or similar tool to remove the center knock-out panel in the wall-mounting base. Screw the base to the wall (thin end...
Page 16
Optional equipment must meet with local regulatory approval standards. Auxiliary (Customer Supplied) The KSU provides a control contact to operate an external ringer. It does not provide ring current or DC voltage. The ringer relay contacts must more than 50 from a 30 Vdc source. 1.Follow the manufacturer’s installation instructions. 2.Connect the Auxiliary Ringer generator to the distribution block as shown in Chart 2 Internal Wiring. External Music source (Customer Supplied) This equipment...
Page 17
Installing optional equipment , , Background each can also be controlled at the telephone: External (Customer Supplied) The paging system uses the speakers on telephones and can also be used with external loudspeakers provided by the customer. The paging output from the KSU is 775 across an input impedance of 600 1.Follow the manufacturer’s installation instructions. 2.Connect the paging system audio input to the distribution block as shown in Chart 2 Internal Wiring. 3.Connect the...
Page 18
Programming a newly installed system involves the completion of the following programming steps:’ System Startup Configuration General Administration Programming overview System Startup System Startup is performed only when the system is first installed. System Startup allows you to one of three programming templates: Square, Hybrid, or PBX. Each template initializes all of the programming data to system wide defaults. Configuration Allows programming of basic line and telephone characteristics....
Page 19
12 Programming Set Copy This feature is to copy of system programming (Configuration and Administration) from on8 to another. programming on individual can also copied, but system-level programming will copied along with it. Copy appears on display as Set COPY and is by using Configuration code. System Version System Version you to not8 version numbers of the software in the System Processor (SP) software, residing in the Feature Cartridge. Version numbers can be used to determine...
Page 20
Programming 13 Chart 3 Programming Overview 5. 6. Service Modes The M7208, and M7324 Telephones can be used with the Compact system. Programming is done with an M7208, M7310, or M7324 Telephone. as shown on the following page.