Page 431
Operation To store a series of operations in a One-Touch Key: 1. Press idle CALL key. 2. Dial 852. 3. Press the One-Touch Key you want to program. 4. Enter the sequence of operations you want to store (up to 24 entries). You can store the following operations: Service Codes Digits 0-9, # and * SPK, DND, VOLUME and VOLUME , CALL, HOLD DIAL, FLASH, LND, CONF (TRF), CHECK, and CLEAR keys One-Touch Keys 1 Function Keys Pause (by pressing MIC) 5. Press the Serial Operations key (PGM 1006 or SC...
Page 432
Paging, External Description 124i Available — eight External Paging zones and eight alarm circuits maximum. 384i Available — eight External Paging zones and 16 alarm circuits maximum. - Combined Paging is always available. - Combined Paging is available prior to system software 3.04 only if a PGDU is installed. With External Paging, a user can broadcast announcements over paging equipment connected to external Paging zones. When a user pages on of these external zones, the system broadcasts the...
Page 433
Programming Start Should system have External Paging?Set up PGDU PCB for External Paging.Refer to the system Hardware Manual. (384i Only) In 1603, assign an External Paging zone (PGDU port 1-8) to a Tenant Group (1-4).In 1606, assign the External Zones set in 1603 to External Paging Groups 1-8. This is used for calling the zones. Should two beeps (i.e., splash tone) precede External Paging announcements? In 1604 Item 1, enter 1.In 1604 Item 1, enter 0. When an External Paging zone is idle, should it...
Page 434
Programming (Cont’d) No YesNo YesYesNoNo Yes Stop In 1006, do not assign function keys for External Zone Paging (code 1004 + zone) and External All Call Paging (code 1005).In 1006, assign function keys for External Zone Paging (code 1004 + zone) and External All Call Paging (code 1005).Should extension have one-button access to External Paging? In 1005, assign Class of Service to extensions. In 0406 Item 22, enter 0.In 0406 Item 22, enter 1.Should extension be able to use External Paging? In 0405 Item...
Page 435
Programming (Cont’d) ➣ 0119 - External Page and Door Box CODEC Gain Type Setup Set the five CODEC gain types for External Page and Door Box ports. ➣0120 - External Page and Door Box CODEC Gain Setup Assign a CODEC gain type from Program 0119 to external Page and Door Box Ports. ➣0405 - System Timers (Part A), Item 18: Page Announcement Duration Set the maximum allowable duration for a Paging announcement. ➣0406 - COS Options, Item 22: External Paging In an extension’s COS, enable (1) or disable (0) the...
Page 436
Paging, Internal Description 124i Available — eight Internal Paging Groups (Zones). 384i Available — 32 Internal Paging Groups (Zones). Internal Paging lets extension users broadcast announcements to other keyset users. The 384i system allows All Call (all zone) Paging and up to 32 separate Internal Paging Zones in each tenant group. The 124i system allows up to eight Internal Paging Zones. When a user makes a Zone Paging announcement, the announcement broad- casts to all idle extensions in the zone...
Page 437
Programming Start Should extension be in an Internal Paging zone?In 1601, assign an extension to an Internal Paging zone (1-8 in 124i, 01-32 in 384i). In 1601, enter 0. When Paging, should user see a Paging zone name or the zone number on the telephone display?In 1602, program names for the Internal Paging zones (1-8 in 124i, 01-32 in 384i).In 1602, do not program names for the Internal Paging zones (1-8 in 124i, 01-32 in 384i). Should the tones that precede an Internal Page be normal volume, muted or...
Page 438
Programming (Cont’d) Continued from previous page. Should extension be able to use Internal Paging?In 0406 Item 52, enter 1.In 0406 Item 52, enter 0. In 1005, assign Class of Service to extensions. Should extension have one-button Internal Zone Paging?In 1006, do not assign function keys for Internal Paging zones or Internal All Call.In 1006, assign function keys for Internal Paging zones (code 1006 + zone) and Internal All Call (code 1076).Paging zones are 1-8 in 124i, 01-32 in 384i). Should extension...
Page 439
Programming (Cont’d) ➣ 0405 - System Timers (Part A), Item 18: Page Announcement Duration Set the maximum allowable duration (0-64800 seconds) for a Paging announcement. ➣0406 - COS Options, Item 52: Internal Paging In an extension’s Class of Service, enable (1) or disable (0) an extension’s ability to make an Internal Pag- ing announcement. ➣1005 - Class of Service Assign a Class Of Service (1-15) to an extension. ➣1006 - Programming Function Keys Assign function keys for Internal Paging Zones (code...
Page 440
Related Features Paging, External An extension user can broadcast an announcement over an External Paging Zone. Programmable Function Keys Function keys simplify Internal Paging operation. Tenant Service An extension user cannot broadcast an announcement into another tenant’s Paging Zones. Operation To make an Internal Page announcement: Keyset 1. Press the zone’s Internal Paging key (PGM 1006 or SC 851: 1006 + 1-9 or 01-32 for zones, 1076 for All Call). OR 1. Press idle CALL key. 2. Dial 801 and the...