Home > Nitsuko > Communications System > Nitsuko 124i/384i Software Manual

Nitsuko 124i/384i Software Manual

Here you can view all the pages of manual Nitsuko 124i/384i Software Manual. The Nitsuko manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 431

Operation
To store a series of operations in a One-Touch Key:
1. Press idle CALL key.
2. Dial 852.
3. Press the One-Touch Key you want to program.
4. Enter the sequence of operations you want to store (up to 24 entries).
You can store the following operations:
Service Codes
Digits 0-9, # and *
SPK, DND,  VOLUME 
 and VOLUME 
, CALL, HOLD
    DIAL, FLASH, LND, CONF (TRF), CHECK, and
    CLEAR keys
 One-Touch Keys
1
Function Keys
Pause (by pressing MIC)
5. Press the Serial Operations key (PGM 1006 or SC...

Page 432

Paging, External
Description
 124i Available — eight External
Paging zones and eight alarm
circuits maximum. 384i Available — eight External Paging
zones and 16 alarm circuits
maximum. 
- Combined Paging is always available. - Combined Paging is available prior
to system software 3.04 only if a
PGDU is installed.
With External Paging, a user can broadcast announcements over paging equipment connected to external Paging
zones.  When a user pages on of these external zones, the system broadcasts the...

Page 433

Programming
Start
Should system have
External Paging?Set up PGDU PCB
for External Paging.Refer to the system
Hardware Manual.
(384i Only) In 1603, assign
an External Paging zone
(PGDU port 1-8) to a Tenant
Group (1-4).In 1606, assign the External
Zones set in 1603 to External
Paging Groups 1-8. This is used for calling
the zones.
Should two beeps (i.e.,
splash tone) precede
External Paging
announcements?
In 1604 Item 1,
enter 1.In 1604 Item 1,
enter 0.
When an External
Paging zone is idle,
should it...

Page 434

Programming (Cont’d)
No YesNo YesYesNoNo
Yes
Stop
In 1006, do not assign
function keys for External
Zone Paging (code 1004 +
zone) and External All Call
Paging (code 1005).In 1006, assign function
keys for External Zone
Paging (code 1004 +
zone) and External All Call
Paging (code 1005).Should extension have
one-button access to
External Paging?
In 1005, assign
Class of Service to
extensions.
In 0406 Item 22,
enter 0.In 0406 Item 22,
enter 1.Should extension be
able to use External
Paging?
In 0405 Item...

Page 435

Programming (Cont’d)
➣
0119 - External Page and Door Box CODEC Gain Type Setup
Set the five CODEC gain types for External Page and Door Box ports.
➣0120 - External Page and Door Box CODEC Gain Setup
Assign a CODEC gain type from Program 0119 to external Page and Door Box Ports.
➣0405 - System Timers (Part A), Item 18: Page Announcement Duration
Set the maximum allowable duration for a Paging announcement.
➣0406 - COS Options, Item 22: External Paging
In an extension’s COS, enable (1) or disable (0) the...

Page 436

Paging, Internal
Description
 124i Available — eight Internal Paging
Groups (Zones). 384i Available — 32 Internal Paging
Groups (Zones).
Internal Paging lets extension users broadcast announcements to other keyset users. The 384i system allows All
Call (all zone) Paging and up to 32 separate Internal Paging Zones in each tenant group. The 124i system allows
up to eight Internal Paging Zones. When a user makes a Zone Paging announcement, the announcement broad-
casts to all idle extensions in the zone...

Page 437

Programming
Start
Should extension
be in an Internal
Paging zone?In 1601, assign an
extension to an Internal
Paging zone (1-8 in 124i,
01-32 in 384i).
In 1601, enter 0.
When Paging, should user
see a Paging zone name
or the zone number on the
telephone display?In 1602, program names
for the Internal Paging
zones (1-8 in 124i, 01-32
in 384i).In 1602, do not program
names for the Internal
Paging zones (1-8 in
124i, 01-32 in 384i).
Should the tones that
precede an Internal Page
be normal volume, muted
or...

Page 438

Programming (Cont’d)
Continued
from
previous
page.
Should extension
be able to use
Internal Paging?In 0406 Item 52,
enter 1.In 0406 Item 52,
enter 0.
In 1005, assign Class of
Service to extensions.
Should extension
have one-button
Internal Zone Paging?In 1006, do not assign
function keys for
Internal Paging zones
or Internal All Call.In 1006, assign function keys
for Internal Paging zones
(code 1006 + zone) and
Internal All Call (code 1076).Paging zones are 1-8 in
124i, 01-32 in 384i).
Should extension...

Page 439

Programming (Cont’d)
➣
0405 - System Timers (Part A), Item 18: Page Announcement Duration 
Set the maximum allowable duration (0-64800 seconds) for a Paging announcement.
➣0406 - COS Options, Item 52: Internal Paging
In an extension’s Class of Service, enable (1) or disable (0) an extension’s ability to make an Internal Pag-
ing announcement.
➣1005 - Class of Service
Assign a Class Of Service (1-15) to an extension.
➣1006 - Programming Function Keys
Assign function keys for Internal Paging Zones (code...

Page 440

Related Features
Paging, External
An extension user can broadcast an announcement over an External Paging Zone.
Programmable Function Keys
Function keys simplify Internal Paging operation.
Tenant Service
An extension user cannot broadcast an announcement into another tenant’s Paging Zones.
Operation
To make an Internal Page announcement:
Keyset
1. Press the zone’s Internal Paging key (PGM 1006 or SC 851: 1006 + 1-9 or 01-32 for zones, 1076 for
All Call).
OR
1. Press idle CALL key.
2. Dial 801 and the...
Start reading Nitsuko 124i/384i Software Manual