NDA-24230 Issue 2.0Page 4-23 VisuaLink 128/384 User Guide Chapter 4 4.3 Software Setup When you first turn on your VisuaLink, there will be an initial configuration screen. These configuration screens will have to be completed before your system becomes operational. Start up configuration screens The following are the startup screens that will be active on first power up or acti- vated on demand by the user after choosing the Environmental initialize. Welcome Screen: This is a welcome screen for the User. Vi s u a L i n k Thank you for purchasing one of the most simple and portable video conferencing systems available. We will now show you how to set up your system. This will only have to be done once. NOTE: If remote controller doesn’t work, make sure the switch setting of D30 camera IR out is ON. Switch is located on the bottom of the camera. Click here to continue Configure laters Note is yellow.

Page 4-24NDA-24230 Issue 2.0 Chapter 4 VisuaLink 128/384 User Guide Remote Controller Directions: Gives some general directions for configure the VisuaLink system. Using the Remote controller highlight the NEXT option to advance to the configure screen or press the lower portion of the CAMERA CONTROL key to highlight the Configure Later to advance to the normal ICON screens. If you choose to configure later, the system will have to be programmed with My numbers and SPID’s in order to work correctly. 4.4 Setting Up your ISDN Line InformationThe following is a description of BRI Line setup Part 1- Remote Controller Location - Locate the CAMERA control. The CAMERA control key is the BLUE round key. Use this key to move the Cursor up/down and Left/Right in the Configuration Screens. - Locate the ENTER key on the Wireless remote controller. Use the ENTER key to confirm selections and store information. Next screen Prior screen s Part 2- Setting up Your ISDN Line Introduction: When ordering BRI service, you will usually get 2 My numbers and 2 SPID numbers per BRI. A SPID normally consists of the user’s 3 digit area code, 7 digit ISDN telephone number, followed by a 0101. Ex: MY Number 1: 9727195854 SPID 1: 97271958540101 Note: The VisuaLink 128 requires 2 My numbers and 2 SPID #, while the VisuaLink 384 requires 6 My numbers and 6 SPID #. Next screen Prior screen s Note is yellow.

NDA-24230 Issue 2.0Page 4-25 VisuaLink 128/384 User Guide Chapter 4 Video Number 1 Screen’s Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 1). Each BRI will have My numbers labeled #1 and #2 and two SPID’s . All four numbers must be entered. Choose NEXT when complete. Note: “PROCEED TO STEP 2” will only be shown on the VisuaLink 128 system. VisuaLink 384 will show “ Proceed to Line 2 Setup” Step 1--Enter My Number and SPID for BRI LINE 1 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s Step 1--Enter My Number and SPID for BRI LINE 1 My Number 1: [9727195854] SPID 1: [97271958540101] My Number 2: [9727195855] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s

Page 4-26NDA-24230 Issue 2.0 Chapter 4 VisuaLink 128/384 User Guide Video Number 2 Screens: Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 2). Each BRI will have My numbers labeled #1 and #2 and two SPID’s . All four numbers must be entered. Choose NEXT when complete. Note: This screen will only appear on the VL 384 system. Step 1--Enter My Number and SPID for BRI LINE 2 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s

NDA-24230 Issue 2.0Page 4-27 VisuaLink 128/384 User Guide Chapter 4 Video Number 3 Screens: Using the number pad of the wireless remote enter My Number with area code and SPID numbers associated to Line (BRI 3). Each BRI will have My numbers labeled #1 and #2 and two SPID’s . All four numbers must be entered . Choose NEXT when complete. Note: This screen will only appear on the VL 384 system. 4.5 Optional User Settings:The following is a description for Optional Setting screen. Step 1--Enter My Number and SPID for BRI LINE 3 My Number 1: [] SPID 1: [ ] My Number 2: [ ] SPID 2: [ ] Next screen Prior screen Press ENTER after choosing each item s Part 3 - Optional User Settings Introduction: Site Name: Name identification for your location. Name is displayed on far-end monitor when site is viewed. Password: Required to gain access to the VisuaLink configuration screens. Time setting: Sets the internal clock for the Vi s u a L i n k . Next screen Prior screen s

Page 4-28NDA-24230 Issue 2.0 Chapter 4 VisuaLink 128/384 User Guide Optional information: You may enter this optional information. The name you enter makes it easy for users to identify this particular VisuaLink. The name can be up to 20 characters long. The Password is the password needed to be entered when selecting the Utilities ICON. After entering the optional information select the NEXT to advance to the next screen. Application Screen’s Using the number pad on the wireless remote controller select the application which the VisuaLink is installed. Your answer to this question will automatically configure the internal parameters for the following: Step 1- Optional User Settings Your Site Name [ ] Password [ ] Time Setting [12/1/1998 10:50] Time Display: Auto Power Save: Next screen Prior screen Press ENTER after choosing each items Item Rollabout/Other Data Conference Gateway Desktop Serial Port 1 Camera EVI-D30 T.120 Camera Camera Serial Port 2 Console Console Console Console Audio Mode G.722 G.728 G.722 G.722 MLP 4.0 24.0 4.0 4.0 Answer Mode Auto Auto Auto Manual LSD 1.2 Off 1.2 1.2 Ext. Remote Auto Off Off Off H.263 Off Off Off Off Lip Sync On On On On

NDA-24230 Issue 2.0Page 4-29 VisuaLink 128/384 User Guide Chapter 4 Congratulations Screen The VisuaLink is now setup for the configuration you have entered. Press the ENTER button on the REMOTE CONTROLLER , the VisuaLink will display a blue screen and recycle. The VisuaLink should will power up to a normal state. You may begin to use the video conferencing system immediately. Note: If there are no My Numbers entered in the configuration the VisuaLink will display the Start Up screens. Step 2—Optional User Settings Key in the number of one of the following applications. Applications: 1. Rollabout/Other 2. Data Conference 3. Gateway 4. Desktop Press CANCEL to page back Congratulations, you have just finished setting up your VisuaLink system. For VisuaLink software updates and general VisuaLink knowledge, visit the NEC Knowledge base web site at : http://www.cng.nec.com or http://www.ilibrary.com/phoenix/ntachome.nsf /homepagenav?opennavigator - You may begin to use the video conferencing system immediately. - Press ENTER to activate your configuration. Press CANCEL to page back

Page 4-30NDA-24230 Issue 2.0 Chapter 4 VisuaLink 128/384 User Guide Powering Up Screen Changing the configuration It is important that the CODEC is set up with a local number and SPID numbers. If the unit is not setup with a local number (my number) and SPID, the unit will not allow for dialing and receiving of video calls. If you have entered these numbers in the Start Up configuration, you may ignore this section. If the VisuaLink environment has changed, such as the phone number have changed, you must reconfigures the numbers in the VisuaLink. America, Inc. VisuaLink Powering Up Ver .22.02.37

NDA-24230 Issue 2.0Page 5-1 VisuaLink 128/384 User Guide Chapter 5 Chapter 5 System Parameter/Environment Setting System parameter sets the operation conditions of the VisuaLink 128 or VisuaLink 384. Environment setting can be set such as camera class, audio related, data related, line related and local office status. Loopback feature can be used as a maintenance feature. Note 1: Make system parameter changes when the system is not connected. Note 2: Depending on the setting for audio, data speed and bit rate, and the video has the possibility for not being transmitted. Please refer to Appendix A: Audio/Data/Video Bit Rate Assignment Table for bit rate assignment of audio, data, video bit rate. 5.1 Environment Setting Menu5.1.1 Set an environment ¬ Press the MENU button to display the MAIN MENU . s Setting the PIP parameter.MENU

Page 5-2NDA-24230 Issue 2.0 Chapter 5 VisuaLink 128/384 User Guide Á Move the cursor with the CAMERA CONTROL button to the ENVIRONMENT SETTING icon. Â Press the ENTER button. The system will not operate correctly if the environment setting are incorrect. Therefore, the system has a password so that only the person in charge of controlling video conference can change the settings. Factory default password is 1234 . s Setting environments. CAMERA CONTROL Please input password. [ ] Press ENTER after inputting password. ENTER