NDA-30080 Revision 1.0Page 51 Sentry Installation Guide Emergency Conference The APM Administration main menu displays, as illustrated below: 2. Type i and press Enter to select the Installation of Applications/Packages option. The Installation of Application/Packages screen displays. 3. At the “ Enter Package to be installed” prompt, type applications and press Enter. NEC America APM Administration Wed Jan 31, 1996 APM Platform Release Rel2.0 (Oct 09, 1995) Main MenuAPMDebug FacilitiesHalt APM System File ArchiveInstallation of Applications/PackagesRemoval of Packages Start-up APM System Logout UNIX Enter Option: [] APM Status: ACTIVE Installation of Applications/Packages Available Packages are: applications asl mtl tcpip update x25 Enter Package to be installed: NEC America APM Administration Wed - Jan 31, 1996

Page 52NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide The “Enter Release Media Device” prompt displays. 4. Select the floppy disk device as the installation media by typing f and pressing Enter. The following screen displays: 5. Insert the Emergency Conference diskette into the floppy disk device, and press Enter to continue. The screen displays files in the application installation. Many files may scroll off the screen, until all of the files from the diskette have been processed. NEC America APM Administration Wed Jan 31, 1996 Installation of Applications/Packages Available Packages are: applications asl mtl tcpip update x25 Enter Package to be installed: applications Release Media Devices are: (F)loppy Disk Device (C)artridge Tape Device Enter Release Media Device: Installation Procedure Installing from /dev/fd0 Insert OAI Release Media #1 Enter to continue:

NDA-30080 Revision 1.0Page 53 Sentry Installation Guide Emergency Conference The “Has all release media been loaded” prompt displays, as illustrated below: Has all release media been loaded [y or n] ? x oai/app/econf/install/blding_m.mdf, 210 bytes, 1 tape blocksx oai/app/econf/install/blding.adf, 94 bytes, 1 tape blocks x oai/app/econf/install/Mconf.cfg, 161 bytes, 1 tape blocks . . x oai/chksum_app, 721 bytes, 2 tape blocksx oai/app/econf.ins, 8034 bytes, 16 tape blocks x oai/app/econf/bin/conference, 418059 bytes, 817 tape blocks . . .

Page 54NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide 6. Type y and press Enter to indicate that all release media has been loaded. The APM installation begins, processing all of the Emergency Conference installation files and checking them for correctness. The screen indicates the status of the installation. After the files have been processed, the “root password” prompt displays. In order to complete the Emergency Conference installation, you must modify certain files that require “root” privileges. OAI Platform is at revision 5 for machine i386 (Dec 19 1994 Rel 1.6.1) econf Revision: 5 machine type: i386 Version: 1.7 Processing, please wait... Validating installed files .............. Validation Completed Installing the Release Files Processing files Installation requires Super User (root) privileges. Please Enter su/root Password: NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998

NDA-30080 Revision 1.0Page 55 Sentry Installation Guide Emergency Conference 7. Type in the root password at the prompt and press Enter to continue the Emergency Conference installation. The Emergency Conference installation creates any directories that do not already exist. The paths of the directories display on the screen, as illustrated below. 8. Press Enter. The “ Override Conference Pilot Number” prompt displays: Creating Emergency Conference directories . . . /oai/app/sentry created NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 /oai/app/sentry/bin created/oai/app/sentry/install created/oai/app/sentry/cfg created/oai/app/sentry/cfg/history created/oai/log already exists/oai/log/sentry created Press Enter to continue. [ ] Please type the Override Conference Pilot Number, then press Enter:[] NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998

Page 56NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide 9. Type the number your site will use to override a busy destination, such as 1000. This number can contain no more than 5 characters. 10. If you have entered the correct pilot number, type y and press Enter to verify your entry. Otherwise, type n and press Enter, and enter the correct value. After you have entered and verified the pilot number, the “ Override Tone Phone Number ” prompt displays. 11. The Override Tone Phone number specifies the dummy phone extension which is used to provide a warning tone when a busy destination is overridden. Type the appropriate dummy phone number, such as 1001, and press Enter. Verify this number by typing y and pressing Enter. The “ default error destination” prompt displays. Please type the Override Tone Phone Number, then press Enter: [] NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 Please type the default error destination, then press Enter: [] NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998

NDA-30080 Revision 1.0Page 57 Sentry Installation Guide Emergency Conference 12. The default error destination specifies the extension number of the destination that receives transferred parties that could not be reconnected to the transferring party. Type the extension number to receive transferred parties when the line is busy, and press Enter. Type y and press Enter to verify this number. . 13. If you want released contacts to be redialed if a caller joins an active conference, type y and press Enter twice. Do you want released contacts to be redialed if a caller joins NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 an active conference?(y/n) [] During initialization, do you want parties connected to a NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 conference call set to be automatically released? (y/n) []

Page 58NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide 14. If you want parties to be connected to a conference card set to be automatically released during initialization, type y and press Enter twice. Otherwise, type n and press Enter. Confirm your entry at the prompt. The “Service Feature Class” prompt displays. 15. Do one of the following: If you want to disable the flash hook feature while a station is connected to a conference, type y and press Enter. If you do not want to disable the flash hook feature while a station is connected to a conference, type n and press Enter. Then go to step 17. 16. If you wanted to disable the flash hook feature while a station is connected to a conference, type the number between 1 and 15 that you want to use to disable the feature and press Enter. Then verify this number by typing y and pressing Enter. Are you using a Service Feature Class (SFC) to disable the flash NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 hook feature while a station is connected to a conference? (y/n) [] Please type the Service Feature Class (SFC) Number (1...15) NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 used to disable the flash hook feature, then press Enter? []

NDA-30080 Revision 1.0Page 59 Sentry Installation Guide Emergency Conference 17. The Emergency Conference Auto-Configuration program installs the default configuration. This screen displays whether or not you disabled the flash hook feature. 18. Press Enter to start the auto-configuration. The status of the configuration displays, as illustrated below: The default Emergency Conference Application Configuration NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 Press Enter to continue. [ ] will now be installed by the autoconfig program. After theEmergency Conference Installation has concluded, be sure tocheck the configuration using the Applications Manager (APM)and modify any settings that are different on your system. Emergency Conference Auto-Configuration NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 /oai/utils/autocfg running . . ./oai/utils/autocfg: Sentry_Conference application configured./oai/utils/autocfg terminated normally. Emergency Conference Auto-Config Complete Press Enter to continue. [ ]

Page 60NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide 19. Press Enter to continue the installation process. 20. Press Enter to continue. The following screen displays when the installation is complete. 21. Press Enter. Installing the Emergency Conference Binary . . . NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 Installing the Conference Database Files . . . Installing the Conference Card Database Files . . . Installing the Tenant Database Files . . . Press Enter to continue. [ ] Installing the Building Database Files . . . Installing example Contact Database Files . . . Installing example Authorized Caller Database Files . . . Installing the History Log Configuration Files . . . Emergency Conference Installation Complete. NEC America Inc. Emergency Conference Installation Wed - Apr 29, 1998 Press enter to Continue. [ ]