    							NDA-30080   Revision 1.0Page 1
    Sentry Installation Guide Introduction
    Chapter 1 Introduction
    This manual describes the installation, databases, and configuration for the Sentry 
    Alarm Control Terminal and the applications that can be used with the terminal.
    Overview
    This manual contains the following chapters:
    Chapter 1, Introduction - Describes the chapters in this installation guide.
    Chapter 2, Sentry Alarm Control Terminal - Provides an overview of Sentry 
    Alarm Control Terminal and describes the installation, databases and configuration 
    parameters.
    Chapter 3, Annoyance Trap - Provides an overview of the Annoyance Trap 
    application and describes the installation, configuration parameters, and databases.
    Chapter 4, Emergency Conference - Provides an overview of the Emergency 
    Conference application and describes the installation, configuration parameters, 
    and databases.
    Chapter 5, Executive Override - Provides an overview of the Executive Override 
    application and describes the installation, configuration parameters, and databases. 
    Also provides a sample configuration.
    Chapter 6, MAT Assignments and PBX Information - Describes the NEAX 
    Maintenance Administration Terminal (MAT) commands that need to be used for 
    each OAI Monitor application as well as the PBX software and conference cards 
    that you need to run Sentry Alarm Control Terminal
    Chapter 7, Platform Maintenance - Describes how to use the platform 
    maintenance utility to perform administrative tasks, including: activating, 
    deactivating, and resetting terminals.
    Appendix A, History Logging - Provides a description of the History Logging 
    configuration. 
    						
    							Introduction Sentry Installation Guide
    Page 2NDA-30080   Revision 1.0
    This Page Left Blank. 
    						
    							NDA-30080   Revision 1.0Page 3
    Sentry Installation Guide Sentry Alarm Control Terminal
    Chapter 2 Sentry Alarm Control Terminal
    This chapter describes the databases and configuration parameters for the Sentry 
    Alarm Control Terminal software. For information about using the Sentry Alarm 
    Control Terminal, see the Sentry Alarm Control Terminal User Guide.
    Overview
    The Sentry Alarm Control Terminal is a versatile UAP operator interface 
    application that communicates with one or more Sentry OAI Monitor applications 
    (such as the Emergency Conference Monitor or the Annoyance Trap Monitor) 
    using message protocols defined by these applications. Data received from the 
    monitors is displayed in real time. 
    Multiple instances of the Sentry Alarm Control Terminal may be executed 
    simultaneously from the system console and/or from one or more dumb terminals 
    connected to the UAP via RS-232. The content and format of displayed data is 
    controlled through configuration files, allowing a high degree of customization. 
    Each terminal can use a separate configuration, or configurations can be shared.
    The Sentry Alarm Control Terminal uses text windows to display information and 
    allows the user to manipulate window text from a keyboard. Special function keys 
    are defined to permit the user to quickly perform needed tasks. System messages 
    are used to inform the user of errors and other status changes. Dialog windows are 
    displayed to show current configuration settings or when the program requires 
    information from the user.
    The following features are controlled through the configuration file set:
    Window and Dialog Attributes
    • Screen position
     Size in rows and columns
     Text colors and attributes (bold, blinking, etc.)
     Static text fields
     Dynamic text field formats
    Real Time Message Display Attributes
     Message text field formats
     Text colors and attributes (bold, blinking, etc.)
    Screen Saver Attributes
     Time out values
     Text colors and attributes (bold, blinking, etc.)
     Static text fields
    Function Key Assignments 
    						
    							Page 4NDA-30080   Revision 1.0
    Sentry Alarm Control Terminal Sentry Installation Guide
    There are several processes included in the Sentry Alarm Control Terminal 
    installation:
    Software Installation - Install software from media and follow prompts.
    Database Creation - Build, process, and install databases.
    Window Configuration Files - Create configuration files for terminal windows.
    Configuration Parameters- Set configuration parameters.
    Activate Terminals - Use platform maintenance tools to activate terminals.
    The following sections describe these processes.  
    						
    							NDA-30080   Revision 1.0Page 5
    Sentry Installation Guide Sentry Alarm Control Terminal
    Software Installation
    The Sentry Alarm Control Terminal software must first be loaded from the release 
    media. Remember to use the Applications Manager (APM) Installation Manual if 
    you need further instructions for installing software using the APM.
    Note:You will be prompted for several values when you install the software. For more 
    information about these and other parameters, refer to the next section, 
    Configuration Parameters on page 16.
    1. To begin the Sentry Alarm Control Terminal software installation, log in to the 
    APM Platform Management Menu by typing apmadm at the UNIX login 
    prompt, then press Enter. The login and password prompts are shown below.
    If your “apmadm” account requires a password, enter the appropriate 
    password at the subsequent password prompt.
    The APM Administration main menu displays.
    login: apmadmpassword:
    NEC America      APM Administration                Wed  Jan 31, 1996
    APM Platform Release  Rel2.0  (Oct 09, 1995)
    Main MenuAPM
    Debug FacilitiesHalt APM SystemFile Archive
    Installation of Applications/PackagesRemoval of PackagesStart-up APM System
    LogoutUNIX
    Enter Option:  []
      APM Status: ACTIVE 
    						
    							Page 6NDA-30080   Revision 1.0
    Sentry Alarm Control Terminal Sentry Installation Guide
    2. Type i and press Enter to select the Installation of Applications/Packages 
    option. The Installation of Application/Packages screen displays.
    3. At the “
    Enter Package to be installed” prompt, type applications and 
    press Enter.  The “
    Enter Release Media Device” prompt displays.
    Installation of Applications/Packages
    Available Packages are:
    applications    asl    mtl     tcpip     update    x25
    Enter Package to be installed: 
    NEC America     APM Administration                Wed - Jan 31, 1996
    NEC America       APM Administration              Wed  Jan 31, 1996
    Installation of Applications/Packages
    Available Packages are:
    applications     asl    mtl    tcpip     update     x25
    Enter Package to be installed:  applications 
    (F)loppy Disk Device           (C)artridge Tape Device
    Enter Release Media Device: Release Media Devices are: 
    						
    							NDA-30080   Revision 1.0Page 7
    Sentry Installation Guide Sentry Alarm Control Terminal
    4. Select the floppy disk device as the installation media by typing f and pressing 
    Enter.
    The following screen displays:
    5. Insert the Sentry Alarm Control Terminal diskette into the floppy disk device, 
    and press Enter to continue.
    The screen displays files in the application installation. Many files may scroll 
    off the screen, until all of the files from the diskette have been processed. 
    The “
    Has all release media been loaded” prompt displays.
    Installation Procedure
    Installing from /dev/fd0
    Insert OAI Release Media #1Enter  to continue: 
    Has all release media been loaded [y or n] ? 
    x oai/app/sentryTrm/install/ansi_sat, 1038 bytes, 3 tape blocksx oai/app/sentryTrm/install/Mdefault.cfg, 434 bytes, 1 tape blocksx oai/app/sentryTrm/install/.profile, 1673 bytes, 4 tape blocks
                                                .
    x oai/chksum_app, 1011 bytes, 2 tape blocksx oai/app/sentryTrm.ins, 8459 bytes, 17 tape blocksx oai/app/sentryTrm/bin/sentryTerm, 540414 bytes, 1056 tape blocks
                                                .
                                                .                                            . 
    						
    							Page 8NDA-30080   Revision 1.0
    Sentry Alarm Control Terminal Sentry Installation Guide
    6. Type y and press Enter to indicate that all release media has been loaded.
    The APM installation begins processing all of the Sentry Alarm Control 
    Terminal installation files and checking them for correctness. The screen 
    indicates the status of the installation. 
    After the files have been processed, the “root password” prompt displays. In 
    order to complete the Sentry Alarm Control Terminal installation, you must 
    modify certain files that require “root” privileges. 
    OAI Platform is at revision 5 for machine i386 (Dec 19 1994 Rel 1.6.1)
    sentryTrm Revision: 5     machine type: i386     Version: 1.7
    Processing, please wait...
    Validating installed files
    ..............
    Validation Completed
                      Installing the Release Files
    Processing files
    Installation requires Super User (root) privileges.
    Please Enter su/root Password:
    NEC America Inc   Sentry Terminal Installation   Wed - Apr 29, 1998 
    						
    							NDA-30080   Revision 1.0Page 9
    Sentry Installation Guide Sentry Alarm Control Terminal
    7. Type in the root password at the prompt and press Enter to continue.
    The Sentry Alarm Control Terminal installation will create any directory that 
    does not already exist. The paths of the directories will display on the screen, 
    as illustrated below.
    8. Press Enter to continue the installation. The sentry user is added to the SCO 
    UNIX operating system.
    Creating Sentry Terminal directories . . .
    /oai/app/sentry created
    NEC America Inc   Sentry Terminal Installation   Wed - Apr 29, 1998
    /oai/app/sentry/bin created/oai/app/sentry/install created/oai/app/sentry/cfg created/oai/app/sentry/cfg/terminals created/oai/app/sentry/cfg/terminals/default created/oai/log already exists/oai/log/sentry created
    Press Enter to continue. [ ]
    Installing sentry user on SCO UNIX.
    Enter (sentry) user id [6000]:
    NEC America Inc   Sentry Terminal Installation   Wed - Apr 29, 1998
    User (sentry) already belongs to a group.
    User (sentry) installed.
    Press Enter to continue. [ ] 
    						
    							Page 10NDA-30080   Revision 1.0
    Sentry Alarm Control Terminal Sentry Installation Guide
    9. Press Enter again and the sntryadm user is added to the SCO UNIX operating 
    system.
    10. A warning indicating that the user ID has already been assigned to the system 
    displays. Type y and press Enter to install the sntryadm user with the same ID.
    The sntryadm user is added to the system.
    Installing sntryadm user on SCO UNIX.
    Enter (sntryadm) user id [6000]:
    NEC America Inc   Sentry Terminal Installation   Wed - Apr 29, 1998
    Warning: The user id [6000] is already assigned on this system,
    Install (sntryadm) with user id [6000] (y/n)
    Installing sntryadm user on SCO UNIX.
    Enter (sntryadm) user id [6000]:
    NEC America Inc   Sentry Terminal Installation   Wed - Apr 29, 1998
    Warning: The user id [6000] is already assigned on this system,
    Install (sntryadm) with user id [6000] (y/n) y
    User (sntryadm) already belongs to a group.
    User (sntryadm) installed.
    Press Enter to continue [ ] 
    						
    All NEC manuals Comments (0)