Page 21
NDA-30115 Revision 1.0Page 11 Property Management System - Communication Interface Architecture Table 2-5 Line Control Characteristics Item Conditions Control Method Contention method (point to point) Operating Mode Half duplex (if modems are used, set to full duplex) Synchronization Synchronous Data Rate 4800 or 9600 bits/second (bps) Frame Contents EBCDIC Error Control Method CRC-16 (X 16 + X15 + X2 + 1) Bit Transmission Order Priority is given to low order bits Transmission Intervals At each data...
Page 22
Page 12NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface The control codes used for the message texts are: Table 2-6 Control Codes Control CodeHexadecimal Va l u eFunction SYN 32 Synchronization code. STX 02 Indicates the start of a block. ETX 03 Indicates the end of a block. ENQ 2D Used as the start sequence code. It indicates a reception request to the other side and a request to answer an infor- mation block just sent. EOT 04 Indicates the end of transmission...
Page 23
NDA-30115 Revision 1.0Page 13 Property Management System - Communication Interface Architecture Transmission ProtocolThe messages sent between the NEAX and the PMS must have header and trailing sections as defined in the following format: Figure 2-5 Base Message Format The elements of the message is as follows: PAD-L -- The leading pad character. (One byte - 55H.) SYN -- Synchronization character. At least three of these should be transmitted. (One byte each - 32H.) STX -- Start of text block....
Page 24
Page 14NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface The message format breaks down as follows: STX -- Start of text block. (One byte - 02H.) SA -- System Address. (One byte - ‘1’ [31H].) UA -- I/O Unit Address. (One byte - ‘!’ [21H].) EI -- Entry Index. (One byte - ‘L’ [4CH].) FTC -- Feature Code. (See below.) A list is provided in Appendix C, “Feature Codes”. MSC -- Message Counter. This represents the length of the message. The count of characters...
Page 25
NDA-30115 Revision 1.0Page 15 Property Management System - Communication Interface Architecture Transmission Sequence Table 2-7 Data Transmission Sequence (1 of 2) Status ENQ STXETX, CRCACK0/ ACK1NAK Neutral (A) a: ACK0 -> (B) b: NAK -> (A) c: ENQ -> (D) Waiting for STX (B)(ACK last received) -> (B)-> (C) Waiting for ETX, CRC (C)f: NAK -> (B) g: EOT -> (A)h: ACK0/1 i: NAK c: RVI j: EOT -> (A) Waiting for ACK after start sequence (D)f: ENQ -> (D) g: EOT -> (A)d: ENQ -> (D) e: EOT ->...
Page 26
Page 16NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface Notes: a: Preparation for reception complete. b: Reception impossible. c: Requests for preparation for reception (the PMS should not request this). d: Transmitted up to 21 times. e: Aborted at 22nd time. f: Transmitted up to 7 times. g: Aborted on the 8th time. h: Message is received normally and preparation for next reception is complete. i: Error found in message. j: Interruption. k: Information...
Page 27
NDA-30115 Revision 1.0Page 17 Property Management System - Communication Interface Architecture Timers and CountersRetransmission Counts Timer Values Table 2-9 Retransmission Counts Meaning Count The number of retransmissions of the start sequence when there is no answer after transmitting the start sequence.7 The number of retransmissions of the start sequence when NAK is received after transmitting the start sequence.7 The number of transmitting ENQs when WACK is received after the transmission...
Page 28
Page 18NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface Cabling ConsiderationsWhen the PMS is connected to the NEAX through a modem, the cables should just be “straight through” cables. There should be no crossing. When the PMS is directly connected to the NEAX, use the following pin assignments: Figure 2-7 Direct Connection Pin Assignments 1FG SD RD RS CS DR SG CD ST 2 RT ER ST 1 2 3 4 5 6 7 8 15 17 20 24FG SD RD RS CS DR SG CD ST 2 RT ER ST 1 1 2 3 4 5 6 7...
Page 29
NDA-30115 Revision 1.0Page 19 Property Management System - Communication Interface Message Descriptions Chapter 3 Message Descriptions There are several message groups: Data Link Maintenance Messages Maid Status Message Waiting Lamp Control Restriction Control Check In/Check Out (Model 60) Check In/Check Out (Model 90) Wake Up/Group Announcement Room Move/Swap/Copy (Model 60) Room Data Change Extension Report Room Recovery (Model 60) Room Recovery (Model 90) Direct Data Entry (Model 90)...
Page 30
Page 20NDA-30115 Revision 1.0 Message Descriptions Property Management System - Communication Interface Recovery Start Report -- After receiving the Nop Test Recover Answer message, the PMS must download NEAX database information (see “Room Recovery (Model 60)” on page 27 and “Room Recovery (Model 90)” on page 28). This message notifies the NEAX of the incoming download. Recovery End Report -- Reports to the NEAX that the PMS database download is complete. Data Link Release Request -- Used by...