NDA-30115 Revision 1.0Page 1 Property Management System - Communication Interface Overview Chapter 1 Overview This document is a description of the interface between the NEC NEAX2400 IMS (hereafter referred to as the NEAX) and the hotel’s Property Management System (PMS). This document contains almost all (see below) of the information specified in the NEAX2400 IMS Hotel System PMS Interface Specifications (document ND- 90265 (E) Issue 2), and is intended to replace it. The PMS and NEAX may...
Page 12
Page 2NDA-30115 Revision 1.0 Overview Property Management System - Communication Interface This Page Left Blank.
Page 13
NDA-30115 Revision 1.0Page 3 Property Management System - Communication Interface Architecture Chapter 2 Architecture The PMS communicates with the NEAX over one or more serial cables. A maximum of three lines can be provided as data links between the NEAX and the PMS. The three lines are designated as Line 1, Line 2 and Line 3. Line 1 is used for Hotel Processing messages; Line 2 and Line 3 are used for Interactive messages. Hotel Processing messages, such as Check In, Check Out and Message...
Page 14
Page 4NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface Asynchronous Transmission Line Control CharacteristicsThe characteristics of the signals transmitted across the communications link are as follows: Table 2-1 Line Control Characteristics Item Conditions Control Method Contention method (point to point) Operating Mode Half duplex (if modems are used, set to full duplex) Synchronization Start-stop system Data Rate 1200, 2400 or 4800 bits/second (bps) Frame...
Page 15
NDA-30115 Revision 1.0Page 5 Property Management System - Communication Interface Architecture The control codes used for the message texts are: Transmission ProtocolBefore a message can be sent, a start sequence (also called a selecting sequence) must be sent to urge the receiver to receive the data. Every transmission sequence will begin with the sender sending a start sequence. The start sequence is a three byte sequence: Figure 2-1 Start SequenceTable 2-2 Control Codes Control...
Page 16
Page 6NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface The messages (but not the control codes or start sequence) sent between the NEAX and the PMS must have header and trailing sections as defined in the following format: Table 2-3 Base Message Format The message format breaks down as follows: STX -- Start of text block. (One byte - 02H.) SA -- System Address. (One byte - ‘1’ [31H].) UA -- I/O Unit Address. (One byte - ‘!’ [21H].) EI -- Entry Index. (One...
Page 17
NDA-30115 Revision 1.0Page 7 Property Management System - Communication Interface Architecture A Violation Code message will be sent to the PMS in the following cases: When the message counter does not match the number of characters received. When a station number not existing in the NEAX is specified in the message data from the PMS. Upon receipt of an invalid Wake Up time (e.g. 25:00). Transmission SequenceThe sequence of transmitting a message is slightly different for the PMS and NEAX....
Page 18
Page 8NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface From the NEAX to the PMS Figure 2-2 NEAX to PMS Protocol Start SequenceAccept Reject No Answer Contention Interrupt Abort PauseMessageAccept Reject No Answer Interrupt Abort Pause End Code Wa i t 1 second SendReceiveReceiveSendSend retry quitretryretry retry retry quitquit quit quit 1 23 4 5 Query 1 - Retry is 3 times; quit on 4th Reject. 2 - Retry is 15 times; quit on 16th No Answer. 3 - Retry is 3 times;...
Page 19
NDA-30115 Revision 1.0Page 9 Property Management System - Communication Interface Architecture From the PMS to the NEAX Figure 2-3 PMS to NEAX protocol Start SequenceAccept Reject Contention Interrupt PauseMessageAccept Reject No Answer Interrupt Pause End Code Wa i t 1 second SendReceiveReceiveSendSend retry quit Query Wa i t 1 second No Answerquit retry continue quit 1 23 4 1 - Do not respond. Immediately cease send attempt and 2 - Ignore Interrupt and send message if 8 messages in queue. 3 - Retry...
Page 20
Page 10NDA-30115 Revision 1.0 Architecture Property Management System - Communication Interface TimersThe following timers are used to maintain data transmission: Sender Timer Upon sending a start sequence, message text or query, this timer begins counting and stops counting upon receiving a valid answer control code. This timer is set to one (1) second. If a timeout occurs after the transmission of a start sequence, a start sequence will be resent up to 15 times. If a timeout occurs during the...